Troubleshooting - Dometic ECOLINE CL440LDC Installation And Operating Manual

Minibar
Table of Contents

Advertisement

Available languages

Available languages

Troubleshooting

8
Troubleshooting
Problem
No voltage present
Voltage is present but
the compressor doesn't
run (connected to AC
supply)
Poor cooling, compres-
sor running for a long
time /continuously
Too cold or a great tem-
perature deviation
18
Possible cause
There is an interruption
in the battery –
electronics connection
Main switch faulty (if
installed)
Additional supply line
fuse has blown (if
installed)
Ambient temperature
too high
Insufficient ventilation
Condenser is dirty
Ambient temperature
too high
Insufficient ventilation
Condenser is dirty
Defective compressor
Suggested remedy
Establish a connection
Replace the main switch
Replace the supply line fuse
Move the refrigerator to another
location
Clean the condenser
Move the refrigerator to another
location
Clean the condenser
Replace compressor
CL440, CL460
EN

Hide quick links:

Advertisement

Chapters

Table of Contents
loading

This manual is also suitable for:

Ecoline cl440lgcEcoline cl460ldcEcoline cl460lgc

Table of Contents