Dometic RH440LDC Installation And Operating Manual
Dometic RH440LDC Installation And Operating Manual

Dometic RH440LDC Installation And Operating Manual

Refrigeration mini fridges

Advertisement

REFRIGERATION
MINI FRIDGES
RH440LDC, RH440LGC, CL440LDC, CL440LGC, CL460LDC, CL460LGC
Minibar
EN
Installation and Operating Manual

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the RH440LDC and is the answer not in the manual?

Questions and answers

Summary of Contents for Dometic RH440LDC

  • Page 1 REFRIGERATION MINI FRIDGES RH440LDC, RH440LGC, CL440LDC, CL440LGC, CL460LDC, CL460LGC Minibar Installation and Operating Manual...
  • Page 3 RH440, CL440, CL460...
  • Page 4 RH440, CL440, CL460 5 mm 5 mm...
  • Page 5 RH440, CL440, CL460 180°...
  • Page 6 RH440, CL440, CL460 180°...
  • Page 7 RH440, CL440, CL460 40 mm...
  • Page 8 RH440, CL440, CL460 90°...
  • Page 9 RH440, CL440, CL460...
  • Page 10 RH440, CL440, CL460...
  • Page 11: Table Of Contents

    RH440, CL440, CL460 Please read this operating manual carefully before starting the device. Keep it in a safe place for future reference. If the device is passed on to another person, this operating manual must be handed over to the user along with it.
  • Page 12: Explanation Of Symbols

    Explanation of symbols RH440, CL440, CL460 Explanation of symbols WARNING! Safety instruction: Failure to observe this instruction can cause fatal or serious injury. CAUTION! Safety instruction: Failure to observe this instruction can lead to injury. NOTICE! Failure to observe this instruction can cause material damage and impair the function of the product.
  • Page 13 RH440, CL440, CL460 Safety instructions • Children must be supervised to ensure that they do not play with the device. • Always keep and use the device out of the reach of children under the age of 8 years. • Do not store any explosive substances such as spray cans with a flammable propellant in the device.
  • Page 14: Intended Use

    Intended use RH440, CL440, CL460 • Danger of overheating! Ensure at all times that there is sufficient ventilation so that the heat that arises during operation does not build up. Make sure that the device is sufficiently far away from walls and other objects so that the air can circulate.
  • Page 15: Technical Description

    Technical description Technical description The cooling device can cool products to a maximum of 26 °C (RH440LDC, CL440LDC, CL460LDC only) or 19 °C (RH440LGC, CL440LGC, CL460LGC only) under the ambient temperature and keep them cool. A grid divider can be used to separate foodstuffs, e.g.
  • Page 16: Operation

    Operation RH440, CL440, CL460 Changing the decorative plate You can change the decorative plate: fig. 4 to fig. 7, page 4. Mounting the sliding hinge (optional) You can mount a sliding hinge that allows the cooling device door to be opened at the same time as the door of the built-in cabinet: fig.
  • Page 17 RH440, CL440, CL460 Operation Using the cooling device NOTICE! Risk of damage • Ensure that the objects placed in the cooling device are suitable for cooling to the selected temperature. • Ensure that food or liquids in glass containers are not excessively refrigerated.
  • Page 18: Cleaning And Maintenance

    Cleaning and maintenance RH440, CL440, CL460 Cleaning and maintenance WARNING! Always disconnect the device from the power supply before you clean and service it. NOTICE! Risk of damage • Never clean the cooling device under running water or in dish water. •...
  • Page 19: Troubleshooting

    RH440, CL440, CL460 Troubleshooting Troubleshooting Problem Possible cause Suggested remedy No voltage present There is an interruption Establish a connection. in the battery – electronics connection. Main switch faulty (if Replace the main switch. installed) Additional supply line Replace the supply line fuse. fuse has blown (if installed).
  • Page 20: Technical Data

    Technical data RH440, CL440, CL460 Technical data The coolant circuit contains R134a. Contains fluorinated greenhouse gases Hermetically sealed equipment RH440LDC RH440LGC Gross capacity: 40 l Connection voltage: 100 – 240 Vw, 50/60 Hz Power consumption: 55 W 12.1 W (100 – 240 Vw, ECO mode) Temprature range: 4 °C …...
  • Page 21 RH440, CL440, CL460 Technical data CL440LDC CL440LGC Gross capacity: 38 l Connection voltage: 100 – 240 Vw, 50/60 Hz Power consumption: 55 W 12.1 W (100 – 240 Vw, ECO mode) Temprature range: 4 °C … 12 °C 4 °C … 12 °C max.
  • Page 22 Technical data RH440, CL440, CL460 CL460LDC CL460LGC Gross capacity: 60 l Connection voltage: 100 – 240 Vw, 50/60 Hz Power consumption: 55 W 12.1 W (100 – 240 Vw, ECO mode) Temprature range: 4 °C … 12 °C 4 °C … 12 °C max.
  • Page 24 Dometic (Pty) Ltd. Dometic Austria GmbH MEXICO Regional Office Neudorferstraße 108 Dometic Mx, S. de R. L. de C. V. South Africa & Sub-Saharan Africa A-2353 Guntramsdorf Circuito Médicos No. 6 Local 1 2 Avalon Road  +43 2236 908070 Colonia Ciudad Satélite...

This manual is also suitable for:

Rh440lgcCl440lgcCl460ldcCl460lgcCl440ldc

Table of Contents