Descri
p
tion
Amplifier pl ug-in
un it'
Time-base u n it
Calibration fixture
Coaxial cable
(2 re quire
d
)
1 Χ
p
assive probe
Termi nation
Τ -con n ector
Screwdriver
P
reliminary
P
rocedure
TA BLE 2-11 (cont.)
L
ist of Test Eq ui pment
R
e
q
uireme nts
Performance
R
equireme nts
Ap plication
Exam ples
B
an
d
wi
d
th , do to 60 MHz;
V
ert and
H
oriz
Ι
α. Te ktronix 5Α48
d
is play mode, CH 1 and
gain c h ec k and
Am plifier plug-i n
d
ual-trace ; deflection
adj ustment.
unit .
factor, 5 mV to 10
V
/
d
iv .
Sweep rate, at least
Sweep timing c hec k
5 ns/div .
and ad justment.
Used to provide
swee p
t
h roug hout
p
rocedure .
Produces gain-c hec k and
V
ert an d H oriz
pulse-response waveforms.
gain c hec k an
d
ad justment.
Im peda nce, 50 Ω ; le ngt h ,
Provides signal
42 inc h; connectors, b n c.
interconn ection .
Com
p
atible with 5A-series
Calibrator sign al
amplifiers used in the
chec k.
oscillosco pe.
Im
p
edance, 50 Ω ; accuracy,
V
ert chec k an
d
with in 2ο/ο; co nn ectors, bnc .
ad j ustment.
Con n ectors, bnc .
E
xtern al
Z-axis
am p lifier c h ec k .
3-inc h
s
h aft, 3/32 i n c h bit .
A d j ustments .
S
p
ecification and
P
erformance C hec k-5440
α. Te ktron ix 51344
Time-Base unit .
α. Te ktronix Calib r a-
tion Fixture
067-0680-00.
α. Te ktronix part
012-0057-01 .
α. Te ktronix Ρ6028
Probe .
α. Te ktronix part
011-0049-01-
a.
Te k tronix part
103-0030-00 .
α . Xcelite
R
3323 .
'Required o nly for Ad justme nt pr oced ure. Α hig h-voltage probe can be used with the DM501 in lieu of the DC voltmete r. Order
010-0277-00 .
'Req uires TM 500-Se ries
P
ower Module.
'A dd ition al amplifier, suc h as 5 Α24 Ν , re qu ired to chec k dual amp lifier operatio n.
4. I nstall α vertical amplifier unit into the left vertical
1 . En sure that the li ne voltage selector bloc k has been
compartment of the 5440 .
in stalled on the correct li ne selector pi ns on the
L
ow
V
oltage and Calibrator circuit board and that th e
regulating ra nge incl ud es the applied linevoltage .
R
eferto
5. Install α time-base u nit i n the
h
orizo ntal com
p
art-
the O p erati ng
V
oltage sectio n of th is manual .
ment of the 5440 .
2. En sure t h at all test equipment is suitably adapte d to
the applie d li ne voltage .
6. Co n nect the eq uipme n t under test a n d t h e test
eq uipment to α suitable li n e voltage source . Turn all
3 . If app licable, install the TM 500-series test equi
p
-
equipment on and allow at least 20 minutes for the
me n t into the test equipment Power
M
o
d
ule.
equi pment to stabilize .
Need help?
Do you have a question about the 5440 and is the answer not in the manual?