330MPX

SPARK ARRESTOR SERvICINg

WARNING
Muffler may be hot
Allow the engine to cool before installing the spark
arrestor.
Do not operate the engine while installing the spark
arrestor.
Clean every 100 hours.

STORAgE

To prepare the engine for long term storage, run the fuel purge
routine in the Set-up Menu.
Store the Ranger in a clean, dry, protected location.

WELDER gENERATOR MAINTENANCE

Blow out the generator and controls periodically with low pressure
compressed air.

BRuSH REMOvAL AND REPLACEMENT

WARNING
Do not attempt to polish slip rings while the
engine is running
Service and repair should only be performed by Lincoln
Electric Factory Trained Personnel. Unauthorized
repairs may result in danger to the technician and
machine operator and will invalidate your factory
warranty. For your safety and to avoid Electric Shock,
please observe all safety notes and precautions.
It is normal for the brushes and slip rings to wear and darken
slightly. Inspect the brushes every 3 months or 200 hours,
whichever comes first.
NORMAL SERvICE INTERvALS
Item
Service
Interval
Oil and
5 hours for
Oil Filter
first oil
change
100 hours
Air Filter 100 hours
Spark
500 hours
Plug
Fuel
200 hours
Filter
Brushes
1000 hours
D-3
MAINTENANCE
TABLE D.1
Replacement part
Part of
number
K3494-1
Service Kit
2.0 qts 10W-30 for
Y
general use
(-5F to 104F, -
20°C to 40°C)
Kohler 12 050 01
Oil Filter
Kohler 24 083 03
Y
Air Filter Element
Kohler 24 083 02
Air Filter Pre-
Cleaner
Champion RC12YC
Y
(.030" gap)
Kohler 24 050 13
Y
Lincoln G9084-C
N

Hide quick links: