14.5. Non-standard printouts

The balance's software enables entering 4 non-standard printouts. Each of
them can consist of approximately 160 characters.
Non-standard printout may include:
Variables depending on the working mode and other needs (mass, date
etc.)
Permanent text form the user menu, however only CAPITAL letters shall
be used, without Polish characters
Non-standard printout can have approximately 160 characters (typed as a
single line)
14.5.1.

Inserting texts

Variables with the same values for all modes
%%
%V
%N
%G
%T
%D
%M
%I
%R
%P
%U
%F
%C
%K
%S
%Y
%1
%2
Print-out of a "%" character
Current net mass in the current unit
Current net mass in the basic unit
Current gross mass in the basic unit
Current tare mass in the basic unit
Current date
Current time
Balance number
Program number
Project number
User number
Name of a current function – working mode
Date and time of the last adjustment
Type of the last adjustment
Currently weighed product
Deviation for the last adjustment
Variable 1
Variable 2