技术参数
电源:直流电源盒 4节5号碱性电池(LR06×4)
电源盒 输入
0.5
0.5~1
K-2012T/H-xx
K-2013T/H-xx
K-2012T-S3-xx
K-2012T-S5-xx
超时用水控制:超时用水1分钟,自动止水。
环境温度:1 ~55
进水温度:0.5~71
适用水压:0.05~
安装步骤
如何安装水龙头
一 龙头与面盆的安装固定
将龙头电控盒及线(8)和进水软管(7)穿
过橡胶垫片(2),并将橡胶垫片(2)嵌
入龙头(1)底部的盘槽中,再将电控盒及
线(8)和进水软管(7)从面盆安装孔穿过,
从台盆下方依次将垫片(3)压片(4)固定环
(5)穿过电控盒及线(8)和进水软管(7),
穿时需先穿电控盒及线(8)再穿进水软管
(7),将固定环按照图示方向拧在牙管
上,用十字螺丝刀将两个螺钉(6)紧固在
固定环上,由螺钉端部压紧压片(4)固定
水龙头。
注意:龙头安装时与电控盒(8)连接的
两根光纤不可弯折,否则会造出感应不灵
敏或不感应现象。
二 安装阀体组件
关闭角阀(11),
对于冷热混水型的阀体组件安装是先将三
通进水软管组件的两端与角阀(11)连
接,然后把阀体组件(9)进水口处的保
护帽旋出,将阀体组件(9)进水口与三
通进水软管组件(10)连接;
对于单冷型的阀体组件安装是把阀体组件
(9)进水口处的保护帽旋出,将主阀体
组件(9)进水口与角阀(11)连接;
1293596-T01-A
220V
约1.9L/min
约1.4L/min
约1.0L/min

TECHNICAL SPECIFICATION

Power: DC Power Unit 4 pieces of AA size alkaline batteries
AC/DC transformer Input
50/60Hz
Overtime Flowing Control: Automatically stop flushing when
the faucet senses an object for more than 1 minute
continuously
Ambient Temperature: 1~55℃
Supply Water Temperature: 0.5~71℃
Supply Water Pressure: 0.05~0.86MPa
1
2
3
4
5
6
7
7
9
10
11
7
9
11
K-2012T/H-xx
About 1.9L/min
K-2013T/H-xx
K-2012T-S3-xx About 1.4L/min
K-2012T-S5-xx About 1.0L/min

INSTALLATION

How to Install the Faucet
1. Secure Faucet on Lavatory
Insert faucet control box/wire (8) and inlet
hose (7) through gasket (2), then seat
gasket (2) in the groove on the underside of
the faucet. Insert faucet control box/wire (8)
8
and inlet hose (7) through lavatory mounting
hole, then insert gasket (3), tab (4) retainer
(5) through control box/wire (8). Remember
insert faucet control box/wire (8) first and
then inlet hose (7), fasten retainer on stud
as shown in the directions. Last, fasten two
screws (6) on retainer, press tab (4) from the
top of screws to secure the faucet.
NOTE: Do not bend two optical fibers
connected between faucet and control box
(8), otherwise, it will cause insensitive or
non-sensing problems.
2.
Install Valve Assembly
Turn valve off (11).
For
mixing
water
installation,
connect
assembly to both ends of stop valve (11),
then unscrew valve assembly (9) water inlet
protection cap, connect valve assembly (9)
inlet to Tee water inlet hose assembly (10);
for cold water faucet installation, unscrew
valve assembly (9) water inlet protection
cap, connect valve assembly (9) inlet to
valve (11);
valve
assembly
water
inlet
hose
5

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents