Nr.
1
Type description
2
Serial number
3
Impeller diameter
4
Temperature of medium
5
Immersion depth
6
Weight
7
Hmax (delivery head max)
8
Hmin (delivery head min)
9
Qmax (delivery volume max)
13
Build year
14
Motor type
15
IE Marking
16
Frequency
17
Voltage
18
Nominal current
19
Motor RPM
20
Power P1
21
Cos phi
22
Insulation class
23
Power P2
24
Start condenser
25
Operating condenser
26
Protection class
27
Operating class
28
Part number
3.3.2. Motor
The motor consists of an engine block and the engine shaft with the impeller assembly. The circuit for power
supply is designed for the maximal mechanical performance according to the characteristics or the nameplate of
the pump. The cable inlets as well as the circuit are sealed resistant to jet water towards the pumped medium.
The shaft bearing is carried out by means of robust, maintenance-free and permanently lubricated antifriction
bearings.
General motor nameplate data
Service factor
Operating mode with immersed motor
Permitted medium temperature
Insulation class
Protection class
Standard cable length
Voltage
Warning - rotating impeller!
Do not touch the rotating impeller or do not reach the pump chamber through the pressure socket!
Never put your hands into the pump chamber or touch the rotating parts in operating mode. Switch the
machine off and let the rotating parts come to gridlock before carrying out maintenance work or repair
work!
Motor cooling
Sufficient motor cooling is also provided for in snore operation due to the water jacket with pressure connection
on top.
3.3.3. Impeller
The impeller is fixed on the engine shaft, which powers
drainage water containing soft solids with a maximum diameter of 10
10
1 Ph
Type description
Serial number
Impeller diameter
Temperature of medium
Immersion depth
Weight
Hmax (delivery head max)
Hmin (delivery head min)
Qmax (delivery volume max)
Build year
Motor type
IE-Marking
Frequency
Voltage
3-phase
Nominal current 3-phase
Motor RPM
Voltage
Star connection
Nominal current Star connection
Insulation class
Power P1
Cos phi
Protection class
Power P2
Operating class
Part number
1.15
S3 20min / S3 40
35°C
F
IP68
10 meters
230V / 1Ph / 50Hz
it.
The impeller is an open multi-channel impeller, for
mm.
3 Ph