Notes; Notes On Installation; Notes On Operation - NEC N8103-123 User Manual

Raid battery backup unit
Table of Contents

Advertisement

6. Notes

Read the following notes thoroughly before using the BBU.

6-1. Notes on Installation

Do not put the BBU on a metallic plate including the chassis of the server. Do not hold
the BBU with wet hands. If you do not follow these directions, the battery may be
short-circuited.

6-2. Notes on Operation

To manage the states of the BBU properly, install the RAID Controller Management
Utility "Universal RAID Utility". Universal RAID Utility allows you to detect errors and
check the states of the BBU.
When using the BBU for the first time, the initial refresh runs automatically. For details,
refer to "Chapter 4 Refresh".
You should schedule the periodic refresh for the stable operation. The standard
interval is the once in 3 months. For details, refer to "Chapter 4 Refresh".
It is sometimes necessary to execute "manual refresh ". For details, refer to "Chapter
4 Refresh".
The following message is registered in RAID log in Universal RAID Utility and OS log
(Event Log or Windows, syslog of Linux).
Log
Event ID
Severity
Description
This event is sometimes recorded when operating in the long time(above the half
year ). When this event is recorded, it is necessary to refresh manually. For
details, refer to
When connecting the BBU newly, this message is sometimes registered during
refresh. After this event is registered, there is not a problem if the following event
is registered within 1 - 2 hours.
Log
Event ID
Severity
Description
 
Raidsrv
508 (800001FC)
Warning
<RU0508> [CTRL:x(ID=x)] The Battery state is unstable.
"Chapter 4 Refresh".
Raidsrv
417 (400001A1)
Information
<RU0417> [CTRL:x(ID=x) LD:x(ID=x)] The Cache Mode of Logical
Drive was changed. (Value : Write Back).
32

Advertisement

Table of Contents
loading

This manual is also suitable for:

N8103-124

Table of Contents