NEC N8103-123 User Manual page 61

Raid battery backup unit
Table of Contents

Advertisement

39
3.
Enter the following command to check Logical Drives on the RAID Controller.
# raidcmd property –tg=ld –c=C –l=L <ENTER>
"C" is the number of the RAID Controller and "L" is the number of the Logical
Drive. Following command is the example when the number of RAID Controller is
"1" and the number of the Logical Drive is "1".
# raidcmd property –tg=ld –c=1 -l=1 <ENTER>
"Auto Switch" mode changes the Cache Mode to Write Back or Write Through
automatically. It judges the two states from the Battery status, whether Battery
status is normal or not.
Tips
4.
The property of the RAID Controller is displayed. Confirm Cache Mode (Setting)
and Cache Mode (Current). Cache Mode should be Auto Switch and Cache Mode
should be Write Back.
RAID Controller #1 Logical Drive # 1
ID
Physical Drive Number
Disk Array Information
RAID Level
Capacity
Stripe Size
Cache Mode (Setting)
Cache Mode (Current)
Status
: 0
: 1, 2, 3
: 1 (order 1/1)
: RAID 5
: 67GB
: 64KB
: Auto Switch
: Write Back
: Online