Indoor Air Quality (Iaq) - Aprilaire 6000 Series Safety & Installation Instructions

Zone control system
Table of Contents

Advertisement

INDOOR AIR QUALITY (IAQ)

The following tables contain the Indoor Air Quality system settings and their details. Default settings are shown in bold. Some settings are only
present dependent upon the value of other settings. The use of an outdoor temperature sensor (recommended) enables additional Indoor Air Quality
functionality. Please refer to the Owner's Manual for further information about control features.
Note: Refer to manuals for humidifier, dehumidifier, air cleaner, and ventilation products for recommended installation and operation.
TABLE 6: HUMIDIFIER SYSTEM SETTINGS
System Setting
Humidifier Installed?
Display Button?
Outdoor Temperature Sensor Installed?
Humidifier Mode
Allowed Humidifier Operation
CAUTION: When Humidifier Operation is set to Without Fan, the control will turn on humidification without energizing the HVAC fan. Do not select this option
when the humidifier is installed on the HVAC duct. Without airflow, moisture can accumulate in the duct resulting in significant damage. Humidity Deadband
Select the minimum difference between the humidifier and dehumidifier setpoints. (Only available if both a humidifier and dehumidifier are installed.)
Humidity Deadband
Humidifier Reminder
Single or First Reminder Appears
Second Reminder Appears
Description
No: Humidifier is not installed. Yes/On HVAC: Humidifier is installed on the HVAC
duct. Yes/Standalone: Humidifier is independent of the HVAC system.
Note: Only available if Humidifier Installed is set to No.
Select if outdoor sensor is attached or not.
Auto: Controls based on setting and outdoor temperature. Manual: Controls
based on RH% setpoint. (Auto mode is only available if Outdoor sensor is set to
Yes.)
Selects when humidification is allowed to occur relative to heating and fan
operation. Without Fan allows humidification to occur without the HVAC fan.
This option should only be used when the humidifier is independent of the HVAC
system. Note: Without Fan is only available when Humidifier Installed is set to
Yes/Standalone.
Select the minimum difference between the humidifier and dehumidifier
setpoints. (Only available if both a humidifier and dehumidifier are installed.)
Selects when the Change Water Panel message is displayed.
Determines the month the first (or only) Change Water Panel message is
displayed.
Determines the month the second Change Water Panel message is displayed.
Factory Default Settings (bold)
and Settings Range
No
Yes/On HVAC
Yes/Standalone
Yes
No
Yes
No
Automation
Auto
Manual
Forces Fan
Heat Only
Heat or Fan
Without Fan
10%
10 to 20%
Off
300h Valve
600h Valve
1 per season
2 per season
October
November
December
January
February
March
April
May
June
July
August
September
October
November
December
January
February
March
April
May
June
July
August
September
19