Table 4: Thermostat System Settings - Aprilaire 6000 Series Safety & Installation Instructions

Zone control system
Table of Contents

Advertisement

TABLE 4: THERMOSTAT SYSTEM SETTINGS

System Setting
Equipment Type
Control Setup
Heat Pump Auxiliary Type
Fan Control In Heating
Number of Compressor Stages
Number of Auxiliary Heat Stages
Number of Stages of Heat
Number of Stages of Cool
Return Air Temperature Sensor Installed?
Outdoor Temperature Sensor Installed?
Schedule Zone 1
Schedule Zone 2
Schedule Zone 3
Progressive Recovery
Display Away Button?
Display Heat Blast Button?
Blast Offset
Extended Fan – Heat
Extended Fan – Cool
Auto Changeover
DeadBand
Auto Changeover Time
Temp Sensor Offset Zone 1
16
Description
Note: Equipment Type related settings will return to defaults if this is changed.
Used to lockout heating or cooling outputs. (Heat/Cool mode only.)
Selects auxiliary type. (Heat Pump mode only.)
Selects thermostat or equipment to control the fan in heating. (Heat/Cool mode
only.)
Select number of compressor stages. (Heat Pump mode only.)
Select number of auxiliary heat stages. (Heat Pump mode only.)
Select number of heat stages. (Heat/Cool mode only.)
Select number of cool stages. (Heat/Cool mode only.)
Select whether return air temperature sensor is attached or not.
Select whether outdoor sensor is attached or not.
Enables or disables programmable schedule. Note: Disabled if Automation.
Enables or disables programmable schedule. Note: Disabled if Automation.
Enables or disables programmable schedule. Note: Disabled if Automation.
Enables or disables progressive recovery.
Away allows the user to set the thermostat to a predefined setpoint using
a single button press. The predefined setpoints can be selected in the User
Settings.
Select whether the Heat Blast button is displayed.
Amount of heating when Heat Blast is initiated.
Extends fan operation after heat call ends.
Extends fan operation after cool call ends.
Enable or disable Auto Changeover mode.
Auto Changeover mode deadband.
Minimum time between heating and cooling calls.
Field adjustment of controlling temperature sensors.
Factory Default Settings (bold)
and Settings Range
Heat/Cool
Heat Pump
Heat & Cool
Heat Only
Cool Only
Gas/Oil Heat
Electric Heat
Gas/Oil Heat
Electric Heat
One
Two
One
Two
One
Two
One
Two
No
Yes
Yes
No
Automation
Enabled
Disabled
Enabled
Disabled
Enabled
Disabled
Enabled
Disabled
Yes
No
Yes
No
3°F (1.5°C)
4°F (2°C)
5°F (2.5°C)
Disabled
Enabled
Disabled
Enabled
Enabled
Disabled
3°F (1.5°C)
2 to 9°F (1 to 4.5°C)
4 Minutes
1 to 5 Minutes
0°F (0°C)
-4 to 4°F (-2 to +2°C)