Technical Data Of The Standard Braking Resistors Hlr01.1; Technical Features Of The Reinforced Braking Resistors Hlr01.1 - Bosch Rexroth IndraDrive Project Planning Manual

Additional components
Hide thumbs Also See for Rexroth IndraDrive:
Table of Contents

Advertisement

9-10
Braking Resistors HLR01.1
9.5
Technical Data of the Standard Braking Resistors
HLR01.1
Braking resistor
HLR01.1N-xxxx-Nxxxx-A-007-NNNN
peak power
peak power duty cycle
load cycle T=120 s
peak power
t_ein max, T=120 s
energy absorption
continuous power
resistance value in operating status
connection cross section
connection cross section
time constant
weight
9.6
Technical Features of the Reinforced Braking Resistors
HLR01.1
Degree of protection IP 20
Dimensioning
0300-N17R5
[kW]
37
0,83
[ED %]
1
[s]
[kWs]
37
[kW]
0,30
[
]
20,5
[mm²]
10
[AWG]
8
[s]
780
kg
3
Fig. 9-12:
Technical data standard braking resistors HLR01.1
• Type A
Cement-coated, wire-wound, tube-type fixed resistors in screwed-on
condition, with side walls and perforated cover, fixed parallel to the
mounting surface, with two connections wired to porcelain terminals in the
mounted terminal box with conduit thread connection.
• Type B and C
Fixed resistor in steel grid version. Depending on the power, with 2 flat
terminals, 2 stud terminals M6 or M8.
The specified braking power is valid for the mentioned relative duty cycle
(ED) of 6 %, 15 %, 25 %, 40 %, and 60 %, relative to a load cycle of
120 s.
Obviously, other duty cycles are allowed as well. The required clearing
time is reduced in the same ratio.
t
:
required clearing time in [s]
aus
t
:
duty cycle in [s]
ein
t
: maximum duty cycle in [s]
einmax
t
: minimum clearing time in [s]
ausmin
Fig. 9-13:
Calculation of the required clearing time
Example: With a duty cycle of 40%, the resistor may be activated for a
maximum of 48 s (t
einmax
shorter duty cycles are allowed as well. The required clearing time is
0470-N11R7
0780-N07R0
56
93
0,83
0,83
1
1
56
93
0,47
0,78
13,7
8,2
25
25
3
3
780
780
4,5
5,5
t
=
×
ein
t
t
aus
aus
min
t
ein
max
), followed by a clearing time of 72 s. Obviously,
DOK-INDRV*-ADDCOMP****-PR02-EN-P
Rexroth IndraDrive
1K08-N05R0
130
0,83
1
130
1,08
5,8
50
1/0
780
8