Connecting Cameras - Sony HDFA-200 Operation Manual

Hd optical fiber adaptor unit
Table of Contents

Advertisement

Connecting Cameras

Connect cameras to the unit, and connect the unit and CCU,
using an optical fiber cable.
Connecting an HDC-P1
HDC-P1
(Left camera)
DC IN
Front
CCU
Settings when connecting HDC-P1 cameras
When an HDFA-200 and HDC-P1 cameras are connected, a
CCA-5 camera control signal cable cannot be connected.
Communication between an HDFA-200 and HDC-P1 is made
with the special sync (UNIVERSAL SYNC) and command
signals overlaid on the HD-SDI signal.
Check that 3D mode is set to ON on the RCP, MSU or CCU.
To set on an HDFA-200
Set REF OUT of CAM1 and CAM2 on the ADAPTER MODE
(M05) page of the MAINTENANCE menu to UNIVERSAL.
For the other settings, see "Preparatory Settings" (page 22).
GENLOCK IN
SDI1
CAM-MAIN(L)
CAM-SUB(R)
REF OUT
SDI IN
REF OUT
SDI IN
CAM-MAIN(L)
CAM-SUB(R)
AUDIO IN 1
DC OUT
DC OUT
MIC
LINE
+48V
LINE
OFF
HDCU1000+HKCU-HB10
Camera Control Unit
HDC-P1
(Right camera)
GENLOCK IN
SDI1
DC IN
Picture monitor
SDI2 OUT
CAM-MAIN(L)
CAM-SUB(R)
SDI1 OUT
SDI2 OUT
TEST OUT
PROMPTER1/
REMOTE
REMOTE
GENLOCK IN
AUDIO IN 2
DC IN
DC OUT
4A max
AUX
CRANE
TRACKER
MIC
+48V
AES/EBU
OFF
HDFA-200
To set on an HDC-P1
Set GENLOCK on the GENLOCK (M13) page of the
MAINTENANCE menu to ENABLE. HV Phase adjustment
value for GENLOCK is automatically invalid.
Viewfinder
VF
REMOTE
VF
RET CTRL
DC OUT
0.5A max
Installation and Connections
15