Installing/mounting

2.3 Mounting instructions

2.3
Mounting instructions
Note
Oscillating rod
Do not bend, shorten or extend the oscillating rod since this will destroy the device.
Note
Direction of the cable glands
When the unit is mounted from the side, ensure that the cable glands face downward and
are closed to avoid water penetration into the housing. The housing can be rotated against
the threaded connection after mounting.
Note
Sealing
Seal the process thread with Teflon tape in case of process pressure.
Note
Precaution for later dismounting/ Service
Grease the screws of the lid if corrosive atmosphere is present (e.g. close to sea).
Note
Switching point
Heavy bulk material -> the signal output switches when the oscillating rod is covered by a
few mm of material.
Light bulk material -> the signal output switches when the oscillating rod is covered a few cm
of material.