Connecting the DS3 Network Cables
"
8
Connection to the DS3 network requires two BNC-to-BNC coaxial cables. The
cables are shipped with the FrameSaver SLV 9580 DSU.
Procedure
To install the DS3 network cables:
1. Take the end of the receive cable and push it onto the DS3 RX (Receive)
connector on the back of the FrameSaver SLV 9580 DSU. Turn the cable
connector clockwise to lock it.
2. Take the end of the transmit cable and push it onto the DS3 TX (Transmit)
connector on the back of the FrameSaver SLV 9580 DSU. Turn the cable
connector clockwise to lock it.
3. Fix the cables to the rail with a cable tie or other strain relief device.
4. Connect the receive and transmit cables to the output and input connectors,
respectively, of the DS3 source.
RX MON
RX
TX
TX MON
5. If the DS3 source device has a variable line build out (LBO) setting, ensure
that it is matched to the cable length.
6. If the cable length is longer than 100 feet (30 meters), set the LBO on the
Network Interface Options configuration screen to Long. The default is Short.
Follow this menu selection sequence to change LBO:
Main Menu
Configuration
June 1999
1
3
2
4
5
Network Interface
DS3
Network
Interface
98-16025
9580-A2-GZ40-10