General Information; Electrical Information - Nabco GYRO TECH GT-1175 Installation Manual

Electrical with u30 control
Hide thumbs Also See for GYRO TECH GT-1175:
Table of Contents

Advertisement

A. G
I
ENERAL
Disconnect all power to the junction box prior to making any electrical connections. Failure to do so may result in
Wiring must meet all local, state, federal or other governing agency codes.
A.1. Electrical Information
Note: Since the Model 1175 Slider is predominantly wired at the factory, the site installer/electrician has a
relatively simple task.
A.1.1 Convenient electric service access holes have been provided in the slide header end caps and
jamb tubes. The installer/electrician should route 120 VAC, single phase, 5 amp (MINIMUM) to
terminal TB1 on the U30 power supply (see Figure A.1.4 below).
TO PREVENT ELECTRICAL INTERFERENCE FOR THE 120 VAC LINE, ALWAYS ROUTE 120 VAC
POWER IN FROM THE END OF THE HEADER THAT IS OPPOSITE TO THE CONTROLLER AND
MOTOR/OPERATOR. SEE FIGURE A.1.4 BELOW. DO NOT ROUTE 120 VAC LINE NEAR
CONTROLLER OR MOTOR/OPERATOR.
The ground wire should be connected to the ground screw located inside the aluminum header.
A.1.2 Wiring diagrams are included in this manual, which reflect the typical primary and secondary circuits
installed at the factory. The low voltage (12 VDC) Reed switch (panic break away) and Acusensors
are easily connected on site using factory installed connector housings. The factory uses Underwriters
Laboratories' (UL) recognized component wire, terminals and connector housings to manufacture the
slider.
A.1.3 The Microprocessor controller has been designed to control the numerous operating characteristics
of the slide door system including opening and closing speeds, recycling and door opening widths. It
will need to be programmed after the installation is complete. (See the Microprocessor Programming
Manual P/N 15-9000 for more details).
F
A.1.4
IGURE
R
OUTE POWER
WIRES IN FROM
BLACK
WHITE
THIS SIDE OF
HEADER
Read and understand the "U30 Controller Setup and Programming Manual" P/N 15-9000
Page 3
NFORMATION
serious personal or fatal injury.
POWER SUPPLY P/N 14-11741
NOISE
FILTER
5
TB1
A
M
P
S1
BLACK (HOT)
WHITE (COM)
GROUNDING WIRE
SCREW TO HEADER
before attempting to power-up the door.
Failure to do so may result in damage to the door
and/or injury to the installer and will nullify all warranties.
WARNING
T1
TB2
MOTOR/OPERATOR P/N 24-11327
CAUTION
www.NabcoEntrances.com
U30 Electrical Installation Manual
U30 CONTROL P/N 24-8901-30
WARNING
No.
To protect against risk of fire
MOTOR? 12P
or electric shock,use only the
Microprocessor Controller
certified NABCO power supply.
Mode SW Usage
POWER
M0
M1
MODE
Open
Open
TWO WAY
61
Open
Gnd
ONE WAY
12VDC+
GYRO TECH
Gnd
Gnd
HOLD OPEN
12VDC-(Common)
6B
Open
Gnd
NIGHT
Interior Activation
Holding Beam
H
Reduced Opening Switch
62
CAUTION
Mode Switch (see Mode SW Usage shown left)
BA
Exterior Activation
ERROR
Sequential Activation
Adjustments to the door can only be made
Breakout Detector
with the NABCO Handy Terminal.
Sidelite Presence Sensor
Contact Output (Class2 Load only)
Do not disassemble the control box.
30V(42.4Vpeak)max.
There are no user serviceable parts
inside.
5Amax.(0-20V), 3.2Amax.(20-30V)
Auxiliary Output (Open-Collector)
To maintain warranty,repairs must be
12VDC-(Common)
made by authorized NABCO facilities.
POWER SUPPLY HARNESS
P/N 14-11874
HANDY TERMINAL? 6P
248901-
16
FUNCTION [SLIDING DOOR]
SYMBOL N o.
15
9DC12V
1
14
7
2
13
61
3
12
6B
4
H
5
11
M0
6
10
M1
7
9
62
8
8
SQ
9
7
BA
10
6
SLS
11
N/O
OUT.A
12
5
N/C
OUT.B
13
4
Common
OUT.C
14
3
OUT
15
2
7
16
1
DN 0291
04-24-08

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents