C. Rocker Switch Settings
Rocker Switch Settings ( w hen wires M0 & M1 are switched to Red 7 the state is indicated by "ON")
Wire
Mode
M0
Two Way
OFF
mode
Hold-open
ON
mode
Reduced-open
-
mode
One-way traffic
ON
mode
Night traffic
OFF
mode
Refer to the tables below. (Off = not switched to common On = switched to common)
Wire M0
Wire M1
Results
OFF
OFF
Two Way Mode: Both sensor signals are available Electric Lock is always unlocked.
OFF
ON
Night Mode: None of the sensor signals will be accepted. Sensors will provide
threshold safety and electric lock is always locked. Activation must occur by means of an exterior
activation device such as a card reader or key switch.
ON
ON
Hold Open Mode: The door keeps the full open point, not affected by sensors. Electric Lock is
always unlocked.
ON
OFF
One Way Mode: The interior sensor activates the door; the exterior sensor provides threshold
safety. Electric Lock is locked until an interior activation is received.
Page 6
Wire
Wire H
M1
In this mode, both sensors on terminals 3 and 8 will receive signals
OFF
-
while the door is closed or cycling.
ON
-
No activation is needed when this selection is made. Door is held open.
-
ON
The door will go to the reduced opening position upon activation.
In this mode, only the sensor on terminal 3 (usually the interior sensor)
will receive signals while the door is closed or cycling. The sensor on
terminal 8 (usually the exterior sensor) will be ignored while the door is
OFF
-
closed. Activation on the secure side is only accomplished by switching
M1 to Red (7). The electric lock will be active to prevent exterior entry.
Refer to diagram D.4.1
No sensor on terminals 3 or 8 will receive signals while the door is
closed. Activation from either side is only accomplished by switching M0
ON
-
to Red (7). During the door cycle both sensors will receive signals. The
electric lock remains locked except for activations from wall plates or
card readers. Refer to diagram D.4.2