B. Terminal Block Assignments
16 Pin Controller Terminal Block Assignments (All wires are identified by color)
No.
Symbol
Color*
1
9DC12V
Brown
2
7
Red
3
61
Black
4
6B
White
5
H
Green
6
M0
Orange
Orange/
7
M1
White
Black/
8
62
Red
9
SQ
Yellow
10
BA
Blue
Green/
11
SLS
White
12
OUT A
Gray
13
OUT B
Gray
14
OUT C
Violet
Brown/
15
OUT
Yellow
16
7
Red
* Color1/Color2 denotes a base wiring Color1 with a stripe Color2. For instance Black/Red indicates a Black wire with
a Red stripe.
NOTE: All references to the signals are made in connection with Common (red).
NOTE: Use a flat-blade screwdriver to remove the terminal connector from the control. Be careful
to ensure all wires are matched to the appropriate terminals. Each terminal is numbered with
Page 5
This output terminal is a sensor power source. The output is 12 VDC with a maximum
capacity of 0.35 amps.
This output terminal provides common ground for the 12 VDC power and
signal source.
This terminal is an activation signal input and will open the door based on a signal from
the sensor that is active in one way mode.
This terminal is the holding beam input, it will open or re-open a door when the holding
beam signal is activated.
This terminal is the reduced opening input. It enables reduced door opening when
switched to Red (7).
This terminal is the mode input switch one (SW1). It is used to achieve special functions
(Refer to section C on page 6).
This terminal is the mode input for switch two (SW2). It is used to achieve special func-
tions. If an electric lock is used, the wire will show the lock's status. (Refer to section C on
page 6)
This input terminal receives the signal from the sensor that is switched out in ONE WAY
mode.
This input terminal allows a sequence of signals to open and close the door.
This input terminal connects directly to Red (7) during normal operation. When the rocker
switch is turned OFF or if the door is panicked open, it is disconnected from Red. It then
stops door operation.
This terminal is the sidelite protection sensor input. At the fully closed position, this input
will prevent the door from opening.
This terminal is connected to the Normally Open contact on an internal relay. It is referred
to as the "auxiliary relay output" elsewhere in this manual. It is used as a switch to se-
quence an electric strike, control other doors in an airlock situation or signal a remote
computer on the door operation.
This terminal is connected to the Normally Closed contact on an internal relay.
This terminal is the common for output wire OUT A or OUT B.
This terminal is connected to an internal transistor with open collector in the Controller.
This terminal provides common ground for the 12 VDC power and signal source.
corresponding information on the face plate of the control.
www.NabcoEntrances.com
U30 Electrical Installation Manual
Description