Download Print this page
Nordson iControl Instruction Sheet
Nordson iControl Instruction Sheet

Nordson iControl Instruction Sheet

Nozzle purge kit installation
Hide thumbs Also See for iControl:

Advertisement

Quick Links

iControl
Introduction
Installation
E 2006 Nordson Corporation
r
Nozzle Purge Kit Installation
This instruction sheet covers the installation of the Single and Dual iControl
Nozzle Purge Kits used for Versa-Spray spray gun nozzle purging. Refer to
your iControl Integrated Control System manual for instructions on
configuring and operating nozzle purge:
S
Original console version: Manual P/N 1024757, version B or above
S
New console version: Manual P/N 1044158
The kits consist of one or two solenoid/pilot-operated valve assemblies, an
air manifold, air tubing, tube fittings, and fasteners.
WARNING: Allow only qualified personnel to perform the following tasks.
Follow the safety instructions in this document and all other related
documentation.
WARNING: Shut down the iControl system, if running, and lock out and tag
electrical power at an external disconnect. Shut off and relieve the iControl
system air supply.
Refer to Figures 1, 2, and 3.
1. Unpack the kit and check the contents with the parts list in this
instruction sheet.
2. Open the console and install the kit hardware and tubing as shown in
Figure 1. Before installing the manifold (12), remove the plug from the
end of the console manifold.
3. Refer to Table 1. Plug the solenoid valve harness(es) into the P5
receptacle(s) on the backplane(s) depending on the number of consoles
in the system, the type of kit you install, and number of banks to be
used.
4. Install 6-mm air tubing from the 4-tube fittings you installed in the rear
panel to the purge adapters on the spray guns.
Instruction Sheet
P/N 1043864A03
Part 1043864A03

Advertisement

loading

Summary of Contents for Nordson iControl

  • Page 1 Follow the safety instructions in this document and all other related documentation. WARNING: Shut down the iControl system, if running, and lock out and tag electrical power at an external disconnect. Shut off and relieve the iControl system air supply.
  • Page 2: Installation

    Nozzle Purge Kit Installation Installation (contd) Console Door Use pipe thread or Rear Panel adhesive/sealant on threads (unused ports) Remove plug, seal, and conduit nut Console Door or Rear Panel To Console Backplane Air Manifold (behind (Remove plug card cage)
  • Page 3 Nozzle Purge Kit Installation Single Kit Schematic Pins 1-2 for consoles A & B - 1 bank purge Pins 3-4 for console B - 2 bank purge Solenoid Valve Pilot-Operated Valve Cardcage and Backplane 10 mm Tubing 12 mm Tubing...
  • Page 4 Configure nozzle purge for the desired number of banks, purge duration, and line gap. Refer to the Configuration and Operation sections of your iControl manual for information, or touch the Help button on the operator interface. E 2006 Nordson Corporation...
  • Page 5 Nozzle Purge Kit Installation Parts To order parts, contact the Nordson Finishing Customer Support Center at (800) 433-9319 or your local Nordson representative. See Figure 4. Item Part Description Quantity Quantity Note 1035665 1035666 1035665 KIT, purge, single, controller...
  • Page 6 Nozzle Purge Kit Installation Figure 4 Purge Kit Parts Issued 11/06 Original copyright date 2003. iControl, Nordson, the Nordson logo, and Versa-Spray are registered trademarks of Nordson Corporation. E 2006 Nordson Corporation Part 1043864A03...