Easy-to-use control system, with software and hardware specifically designed for automated powder coating systems (52 pages)
Summary of Contents for Nordson Encore HD iControl 2
Page 1
For parts and technical support, call the Industrial Coating Systems Customer Support Center at (800) 433-9319 or contact your local Nordson representative. This document is subject to change without notice. Check http://emanuals.nordson.com for the latest version. NORDSON CORPORATION • AMHERST, OHIO • USA...
Page 2
Nordson Corporation welcomes requests for information, comments, and inqui- This is a Nordson Corporation publication which is protected by copyright. ries about its products. General information about Nordson can be found on the Original copyright date 2017. No part of this document may be photocopied,...
Intended Use Use of Nordson equipment in ways other than those described in the documentation supplied with the equipment may result in injury to persons or damage to property. Some examples of unintended use of equipment include: •...
Hardware Manual: Covers installation, troubleshooting, repair, parts, and drawings for this system only. The Encore HD iControl 2 systems can consist of a main console, an auxiliary console, and a pedestal system. Each system can support up to 32 spray guns.
2-8 Overview Special Conditions for Safe Use The Encore HD iControl 2 Integrated Controller Main and Auxiliary Consoles and Display Pedestal with Main Console for Pedestal shall be used within the ambient temperature range of +15°C to +40°C with Encore HD Automatic Powder Applicators.
(new, upgrade, or retrofit) and the equipment furnished by the customer. Therefore, this section provides only basic installation information. Detailed information is contained in the system wiring diagrams, plan views, and other documentation furnished by Nordson application engineering. Once all hardware is installed and wired and the system is powered up, the operator interface is used to configure and operate the system.
Electrostatic discharges occur at very high frequencies, around 100 MHz. An ordinary ground conductor does not conduct such high frequencies well enough to prevent damage to electronic components. Special flat-braided cables are provided with Nordson powder coating equipment to protect against ESD.
Ground Cable Figure 3-7 ESD Grounding Procedures and Equipment Always use the special flat-braided copper ESD ground cables furnished with all Nordson spray gun controllers to ground them. The ESD ground cables should always be attached to the booth base, not to a panel, enclosure, or other component bolted to the base. Keep the cables as short as possible.
NOTE: Not all CompactFlash cards are the same. When additional cards are purchased, make sure they are from a Nordson-approved manufacturer and are 128 Mb or greater. For approved CF cards, refer to Specifications in the Description section of this manual or contact your Nordson controls engineer or Nordson Technical Support.
Check Ethernet wiring. Remote node could be disconnected from network or I/O error turned off. Port or socket open error Programming error. Contact Nordson technical support. Serial port already open Programming error. Contact Nordson technical support. Check Ethernet wiring. Remote node could be disconnected from network or TCP/IP connection error turned off.
Page 65
Replace the PLC. The replacement must be pre-programmed or a program must be downloaded and installed in the field. Contact Nordson Industrial Coating Systems Customer Support for details. − Operation was successful Normal operation. No action required. −...
Page 69
Refer to your system drawings display on iControl 2 for circuit details. screens. If not Nordson USA ColorMax system: Apply jumper to force On the remote disable input. Refer to system drawings for jumper application. Check iControl 2 alarm screen.
Page 75
Check the configured soft top and bottom limits. Make sure they do not allow travel to the limit sensors. Adjust the configured reciprocator Turn-Around Offset (Nordson only) to ensure that the limit sensors are not engaged. Check reciprocator encoder wiring. If signals switched position tracking will be reversed.
Page 77
Refer to your system drawings (continued) iControl 2 screens. for circuit details. If not Nordson USA ColorMax system: Apply jumper to force On the remote disable input. Refer to system drawings for jumper application. Check iControl 2 alarm screen.
Parts Section 6 Parts Introduction To order parts, call the Nordson Industrial Coating Systems Customer Support Center at (800) 433 contact or your local Nordson representative. iControl 2 Controllers Part Description Note Main Consoles 1609712 CONTROLLER, Encore HD, iControl 2, 4 gun, main console...
Drawings Refer to the following foldout wiring diagrams and schematics for the main and auxiliary consoles. NOTE: Visit Nordson eManuals for a high-resolution view of the wiring diagrams and schematics. Go to http://emanuals.nordson.com for electronic version of the manual for Encore HD iControl 2 Integrated Control System manual.
Page 111
Product: Encore HD Automatic Powder Spray System This Declaration is issued under the sole responsibility of the manufacture. Models: Encore HD Automatic Applicator and Encore HD iControl 2 Description: This high density, automatic electrostatic powder spray system includes applicator, control cable and associated controllers.
Page 112
Product: Encore HD Automatic Powder Spray System This Declaration is issued under the sole responsibility of the manufacture. Models: Encore HD Automatic Applicator and Encore HD iControl 2 Description: This high density, automatic electrostatic powder spray system includes applicator, control cable and associated controllers.