For parts and technical support, call the Industrial Coating Systems Customer Support Center at (800) 433-9319 or contact your local Nordson representative. This document is subject to change without notice. Check http://emanuals.nordson.com for the latest version. NORDSON CORPORATION • AMHERST, OHIO • USA...
Nordson Corporation welcomes requests for information, comments, and This is a Nordson Corporation publication which is protected by copyright. inquiries about its products. General information about Nordson can be found on Original copyright date 2019. No part of this document may be photocopied,...
Intended Use Use of Nordson equipment in ways other than those described in the documentation supplied with the equipment may result in injury to persons or damage to property. Some examples of unintended use of equipment include: •...
Dispose of equipment and materials used in operation and servicing according to local codes. System Overview The Nordson Temperature Control Unit (TCU) maintains coating material at the desired application temperature. The temperature control unit heats or cools process water, which then circulates through an external counter-flow water-jacketed heat exchanger.
The temperature control unit is designed to operate at an ambient temperature range of 45-95°F (7.2-35°C). For conditions above or below this temperature range, consult your Nordson representative. Electrical Connections Connect main power to the L1, L2, and L3 terminals at the top of the unit disconnect.
The total combined load should not exceed the capacity of the temperature control unit. Contact your Nordson representative for more information. Plugs are provided at the heat exchange outlet and inlet connections for 3/4 in. NPT barbed hose fittings.
Care must be taken not to bend or flatten the condenser fins when cleaning. In a severely contaminated area, it may be necessary to chemically clean the condenser. Contact a Nordson service representative before attempting to chemically clean the condenser. NOTE: The green indicator should always be visible in the refrigerant sight glass.
Page 40
Refer to Chiller Fault on page 35. If user cannot solve the problem, contact a Nordson representative. Make sure that all air is bled from the heat exchanger on the Air in system material and the water sides.
42 Temperature Control Systems Parts To order parts, call the Nordson Industrial Coating Systems Customer Support Center at (800) 433-9319 or contact your local Nordson representative. System Components Material Out Material In Material Out Material In From Process To Process...
Page 49
C, D, E, F NOTE: A. 120 Vac solenoid used prior to 2015. Check solenoid voltage on unit before ordering. B. Triple TCU units and quad units use a larger chilled water pump. Contact Nordson for correct part number for specific TCU model.
Air Filters Figure 21 Air Filters Item Part Description Quantity Note Single and Dual Systems 1615290 FRAME, filter, aluminum, 3 ton and 5 ton TCU 1615291 FILTER, air, 3 ton and 5 ton TCU Triple and Quad Systems 1615292 FRAME, filter, aluminum, 7.5 ton and 10 ton TCU 1615293 FILTER, air, 7.5 ton and 10 ton TCU...