Page 1
3. Remove the four screws (1) securing the interface card. Save the screws to install the new interface card. 25 CONDUCTOR JACKETED CABLE 50 COND DIGITAL I/O RIBBON CABLE FROM iCONTROL2 CONVEYOR INTERLOCK Figure 1 Old Interface Card with Wiring and Ribbon Cable Connections E 2018 Nordson Corporation Part 1610834−02...
Page 2
CAUTION: Plugging in a ribbon cable the wrong way may damage the cable or circuit boards when power is applied. Reversing the ribbon cable polarity of the cable from the iControl computer to the interface card will cause catastrophic failure of the iControl unit. Make sure the cables are connected correctly.
Page 3
3. Refer to Table 1 with Figure 3 to complete wiring to the interface card. Reconnect the wires of the 25 conductor cable and Table 2 to connect internally to the iControl 2 for the “Conveyor Interlock”. Table 1 iControl Discrete Input Cable Color Code Assignments...
Page 4
Opto-Input Interface Card Replacement Installing New Interface Card (contd) 4. Use Figure 3 and 4 to configure jumpers and comb jumpers. INPUTS 20 HI−23 HI INPUTS 8 HI−15 HI JUMPER JA20−23 JUMPER JA8−15 JUMPER JB20−23 JUMPER JB8−15 (DETAIL 3)
Page 5
Opto-Input Interface Card Replacement Configure iControl 2 to Digital Interface Card Verify the new iControl 2 is properly configured for the new digital interface card, go to the Gun Configuration screen (see Figure 5) and select the digital input card for PCLD782.
Page 6
Opto-Input Interface Card Replacement Issued 01/18 Original copyright date 2018. iControl, Nordson, and the Nordson logo are registered trademarks of the Nordson Corporation. E 2018 Nordson Corporation Part 1610834−02...