Nordson iControl Instruction Sheet

Nordson iControl Instruction Sheet

2 opto-input interface card
Hide thumbs Also See for iControl:

Advertisement

Quick Links

Removing Interface Card
50 COND
DIGITAL I/O
RIBBON
CABLE
1
Figure 1
Old Interface Card with Wiring and Ribbon Cable Connections
E 2018 Nordson Corporation
r
iControl
2 Opto−Input Interface Card
This instruction sheet is to help guide the procedure needed to replace the
iControlr 2 opto-input interface card.
WARNING: Allow only qualified personnel to perform the following tasks.
Follow the safety instructions in this document and all other related
documentation.
WARNING: Shut off all power to the system before beginning any
procedures.
1. See Figure 1. Disconnect the 25 conductor cable wiring at interface
card. Also disconnect the "conveyor interlock" wiring from input 16 thru
19 of the interface card.
2. Disconnect the ribbon cable from the interface card and the computer.
Discard the ribbon cable.
3. Remove the four screws (1) securing the interface card. Save the
screws to install the new interface card.
Instruction Sheet
P/N 1610834−02
Replacement
25 CONDUCTOR
JACKETED CABLE
FROM iCONTROL2
CONVEYOR
INTERLOCK
Part 1610834−02

Advertisement

loading

Summary of Contents for Nordson iControl

  • Page 1 3. Remove the four screws (1) securing the interface card. Save the screws to install the new interface card. 25 CONDUCTOR JACKETED CABLE 50 COND DIGITAL I/O RIBBON CABLE FROM iCONTROL2 CONVEYOR INTERLOCK Figure 1 Old Interface Card with Wiring and Ribbon Cable Connections E 2018 Nordson Corporation Part 1610834−02...
  • Page 2 CAUTION: Plugging in a ribbon cable the wrong way may damage the cable or circuit boards when power is applied. Reversing the ribbon cable polarity of the cable from the iControl computer to the interface card will cause catastrophic failure of the iControl unit. Make sure the cables are connected correctly.
  • Page 3 3. Refer to Table 1 with Figure 3 to complete wiring to the interface card. Reconnect the wires of the 25 conductor cable and Table 2 to connect internally to the iControl 2 for the “Conveyor Interlock”. Table 1 iControl Discrete Input Cable Color Code Assignments...
  • Page 4 Opto-Input Interface Card Replacement Installing New Interface Card (contd) 4. Use Figure 3 and 4 to configure jumpers and comb jumpers. INPUTS 20 HI−23 HI INPUTS 8 HI−15 HI JUMPER JA20−23 JUMPER JA8−15 JUMPER JB20−23 JUMPER JB8−15 (DETAIL 3)
  • Page 5 Opto-Input Interface Card Replacement Configure iControl 2 to Digital Interface Card Verify the new iControl 2 is properly configured for the new digital interface card, go to the Gun Configuration screen (see Figure 5) and select the digital input card for PCLD782.