Download Print this page

M-system R9WTU-ED Instruction Manual

Discrete i/o extension unit

Advertisement

Quick Links

INSTRUCTION MANUAL
DISCRETE I/O EXTENSION UNIT

BEFORE USE ....

Thank you for choosing M-System. Before use, please check
contents of the package you received as outlined below.
If you have any problems or questions with the product,
please contact M-System's Sales Office or representatives.
■ PACKAGE INCLUDES:
Discrete I/O extension unit .................................................(1)
Mounting adaptor ...............................................................(1)
■ MODEL NO.
Confirm Model No. marking on the product to be exactly
what you ordered.
■ INSTRUCTION MANUAL
This manual describes necessary points of caution when
you use this product, including installation, connection and
basic maintenance procedures.
For detailed information of operation and configuration, re-
fer to the Instruction Manual of Multi Power Monitoring
Unit (model: R9xWTU).
5-2-55, Minamitsumori, Nishinari-ku, Osaka 557-0063 JAPAN
Phone: +81(6)6659-8201 Fax: +81(6)6659-8510 E-mail: info@m-system.co.jp
MODEL
POINTS OF CAUTION
■ POWER CONSUMPTION
AC: < 2VA
DC: < 1.5W
■ GENERAL PRECAUTIONS
• Before you remove or mount the unit, turn off the power
supply and input signal for safety.
■ ENVIRONMENT
• Indoor use.
• Do not install the unit where it is directly exposed to rain,
water droplets or sunlight.
• When heavy dust or metal particles are present in the
air, install the unit inside proper housing with sufficient
ventilation.
• Do not install the unit where it is subjected to continuous
vibration. Do not subject the unit to physical impact.
• Environmental temperature must be within -10 to +55°C
(14 to 131°F) with relative humidity within 30 to 90% RH
in order to ensure adequate life span and operation.
■ WIRING
• Wiring to the unit must be conducted by qualified service
personnel.
• Do not install cables close to noise sources (relay drive
cable, high frequency line, etc.).
• Do not bind these cables together with those in which
noises are present. Do not install them in the same duct.
■ AND ....
• The unit is designed to function as soon as power is sup-
plied, however, a warm up for 10 minutes is required for
satisfying complete performance described in the data
sheet.
R9WTU-ED
EM-6225 Rev.1 P. 1 / 4

Advertisement

loading
Need help?

Need help?

Do you have a question about the R9WTU-ED and is the answer not in the manual?

Questions and answers

Summary of Contents for M-system R9WTU-ED

  • Page 1: Before Use

    DISCRETE I/O EXTENSION UNIT MODEL BEFORE USE ..POINTS OF CAUTION Thank you for choosing M-System. Before use, please check ■ POWER CONSUMPTION contents of the package you received as outlined below. AC: < 2VA If you have any problems or questions with the product, DC: <...
  • Page 2 To remove the adaptor, pull it out while squeezing the latch- and pull. es as shown in the figure below. DIN Rail (35 mm wide) push push Mounting Adaptor EM-6225 Rev.1 P. 2 / 4 5-2-55, Minamitsumori, Nishinari-ku, Osaka 557-0063 JAPAN Phone: +81(6)6659-8201 Fax: +81(6)6659-8510 E-mail: info@m-system.co.jp...
  • Page 3: Terminal Connections

    Refer to the figure below for Photo MOS Relay discrete protection and noise removal. •AC •DC Coil, etc. Coil, etc. Inductive loads Inductive loads Load Varistor/CR Circuit Load Varistor/CR Circuit EM-6225 Rev.1 P. 3 / 4 5-2-55, Minamitsumori, Nishinari-ku, Osaka 557-0063 JAPAN Phone: +81(6)6659-8201 Fax: +81(6)6659-8510 E-mail: info@m-system.co.jp...
  • Page 4 Note: When you remove or mount the unit, turn off the power supply and input signal for safety. 3.3 (.13) max Lock mm (inch) EM-6225 Rev.1 P. 4 / 4 5-2-55, Minamitsumori, Nishinari-ku, Osaka 557-0063 JAPAN Phone: +81(6)6659-8201 Fax: +81(6)6659-8510 E-mail: info@m-system.co.jp...