24 | 124 | 224 | 324
Name
Function
Communication object no.
Possible values
Data width
Data point type/data type
Flags (CRWTUI)
Table 29: Volume setting
25 | 125 | 225 | 325
Name
Function
Communication object no.
Possible values
Data width
Data point type/data type
Flags (CRWTUI)
Table 30: Volume state
ISE SMART CONNECT KNX Panasonic
© 2019 ise Individuelle Software und Elektronik GmbH
Volume setting
Sets the volume to the transferred value.
TV 1=24
TV 2=124
TV 3=224
TV 4=324
Percentage as a number: 0|1|2|3|...|100
• 0: No volume.
• 100: Maximum volume.
1 byte
5.001/percent
C-W---
Volume state
Indicates the currently set volume value.
TV 1=25
TV 2=125
TV 3=225
TV 4=325
Volume value as a number (1 to 100).
1 byte
5.001/percent
CR-T--