  • Page 2: Technische Daten

    PRODUKTEIGENSCHAFTEN TECHNISCHE DATEN Spannung 100-240V AC @ 50/60Hz Leistungsaufnahme 250 Watt Breite 720 mm Tiefe 380 mm Höhe 340 mm Gewicht 9,60 kg...
  • Page 3 SICHERHEITSHINWEISE Dieses Produkt darf nur von qualifiziertem Fachpersonal installiert werden. Arbeiten am Gerät dürfen nur von qualifizierten Servicekräften vorgenommen werden. Ein Mindestabstand von 0,5 m zur nächsten Oberfläche muss eingehalten werden. Das Produkt darf nur in gut belüftetenRäumen betrieben werden. Nie direkt in die Lichtquelle schauen.
  • Page 4: Installation

    INSTALLATION BEFESTIGUNG HÄNGEND: Das Gerät kann an dem Haltebügel hängend montiert werden. Hierzu muss eine geeignete Befestigung wie eine Traversenschelle benutzt werden. Bitte achten Sie auf geltende Vorschriften zur Sicherung wie das Anschlagen eines Sicherungsseiles. STROMVERSORGUNG Bei 220~240V: maximal 7 Geräte in Reihe Bei 110~120V: maximal 4 Geräte in Reihe HINWEIS! Wenn das Signalkabel zwischen dem DMX-Kontroller und den...
  • Page 5: Bedienung

    DISPLAYMENÜ BEDIENUNG Menu: Weiter zum nächsten Menü. Enter: Auswahl des aktuellen Punktes. Down: Scrollen durch das Menü oder senken von Werten Scrollen durch das Menü oder erhöhen von Werten. SCHNELLZUGRIFF AUF DIMMFUNKTION Im Hauptmenü den Taster MENU gedrückt halten. Jetzt kann mit den Tasten UP und DOWN der Dimmer bedient werden.
  • Page 6 DIMMER MANUELL Im Menü DIMMING wird der wird das Gerät manuell gedimmt. Siehe auch Schnellzugriff. MENÜ DIMMING 00-100 RUN MODUS Im RUN-MODE Menü wird die Betriebsweise des Gerätes festgelegt. DMX: Das Gerät reagiert auf Eingaben durch einen DMX-Kontroller SLAVE: Das Gerät folgt einem Gerät im Dimmer Mode, wenn es durch XLR-Kabel verbunden ist.
  • Page 7 GERÄTEEINSTELLUNGEN Im SETTING Menü werden die Geräteeinstellungen vorgenommen. Passwort: <UP>+ <DOWN> + <UP> + <DOWN>+<ENTER>. DIM1, DIM2, DIM3 oder DIM4 sind unterschiedliche Dimmerge- schwindigkeiten zur Simulation von Halogenleuchtmitteln. CURVE stellt die Dimmerkurve ein. Siehe Abbildung Dimmerkurve. Im PERFORM Menü wird die Lüfterregelung eingestellt. LIVE regelt den Lüfter für eine ausgewogene Performance gegenüber dem Lüftergeräusch.
  • Page 8 MENÜ SETTING DIMMER DIM 1 DIM 2 DIM 3 DIM 4 CURVE CURVE 1 CURVE 2 CURVE 3 CURVE 4 PERFORM LIVE STUDIO POWER SLOCK PERSONALITY STD. P DMX ERROR SAVE BLACK RESET RESET MODE SETTING SELF MAST PWM_RATE 600 HZ 1200 HZ 2000 HZ 4000 HZ...
  • Page 9 STEUERUNG ÜBER DMX512 KANALBELEGUNG Dieses Gerät verfügt über drei DMX-Personalities. DMX KANAL WERT FUNKTION 0ó255 DIMMER DMX KANAL WERT FUNKTION DIMMER 0ó255 0ó255 FINE DIMMER STD.P DMX KANAL WERT FUNKTION DIMMER 0ó255 0ó255 FINE DIMMER 0ó9 NO STROBE 10ó99 STROBE (SLOW TO FAST) 100ó109 NO STROBE LIGHTNING STROBE (SLOW TO FAST)
  • Page 10 ANHANG EXPLOSIONSZEICHNUNG TEILE TEILE Focus tube components(19 ED) Display PCB Focus tube components(26 ED) Fuse holder Focus tube components(36 ED) PS socket (male) Focus tube components(50 ED) PS socket (male) Handwring screw Adaptor PCB Light tube components M10 hand shank 92 lens fixed cover 15 degree lens(19 in 1) ¦92 convex 1...
  • Page 11: Product Specifications

    PRODUCT SPECIFICATIONS TECHNICAL SPECIFICATION voltage 100-240V AC @ 50/60Hz power consumption 250 Watt width 720 mm depth 380 mm height 340 mm weight 9.60 kg...
  • Page 12: Safety Warning

    SAFETY WARNING This product must be installed by a qualified professional. All maintenance must be carried out by a qualified electrician. A minimum distance of 0.5 m must be maintained between the equipment and a combustible surface. The product must always be operated in a well ventilated area. DO NOT stare directly into the LED light source.
  • Page 13: Power Connections

    INSTALLATION MOUNTING HANGING: The LED fixture can be mounted in a hanging position using the supporting bracket. The bracket should be secured to the mounting truss or structure using a standard mounting clamp. Please note that when hanging the unit a safety cable should also be used.
  • Page 14: Display Panel Operation

    DISPLAY PANEL OPERATION DISPLAY OPERATION Menu: Return to the previous menu. Enter: Enter the currently selected MENU menu. ENTER DOWN Down: Scroll down through the current menu list or increase the value of the current function. Scroll up through the current menu list or decrease the value of the current function QUICK-ACCESS KEYS...
  • Page 15: Run Mode

    DIMMER (DIMMING) DIMMING...this menu allows the user to manually control the intensity of the fixture. Use UP or DOWN keys to select required intensity. MENU DIMMING 00-100 RUN MODE RUN MODE...this menu allows the user to select the operating mode of the fixture.
  • Page 16: Special Settings

    SPECIAL SETTINGS SETTING...this menu allows the user to adjust key operation set- tings for this fixture. KEY...select ON for automatic lock-out. Password to re-enter the display is <UP> + <DOWN> + <UP> + <DOWN>. Select DIM1, DIM2, DIM3 or DIM4 for different dimming speeds. (DIM4 is the slowest dimming speed) CURVE allows the user to adjust the shape of the dimming curve.
  • Page 17 CURVE DIMMING MENU SETTING DIMMER DIM 1 DIM 2 DIM 3 DIM 4 CURVE CURVE 1 CURVE 2 CURVE 3 CURVE 4 PERFORM LIVE STUDIO POWER SLOCK PERSONALITY STD. P DMX ERROR SAVE BLACK RESET RESET MODE SETTING SELF MAST PWM_RATE 600 HZ 1200 HZ...
  • Page 18: Using Dmx512 Controller

    USING DMX512 CONTROLLER CHANNEL ASSIGNMENT Note: This product have two DMX512 channel configuration: UNO / DOS / STD.P CHANNEL VALUE FUNCTION 0ó255 DIMMER CHANNEL VALUE FUNCTION DIMMER 0ó255 0ó255 FINE DIMMER STD.P CHANNEL VALUE FUNCTION DIMMER 0ó255 0ó255 FINE DIMMER 0ó9 NO STROBE 10ó99...
  • Page 19: Parts Diagram

    APPENDIX PARTS DIAGRAM ITEM ITEM Focus tube components(19 ED) Display PCB Focus tube components(26 ED) Fuse holder Focus tube components(36 ED) PS socket (male) Focus tube components(50 ED) PS socket (male) Handwring screw Adaptor PCB Light tube components M10 hand shank 92 lens fixed cover 15 degree lens(19 in 1) ¦92 convex 1...