1. Identification
2. System design
Systems can be either:
2.1 Water hydraulic systems, in which the water is recirculated back to
tank.
2.2 Open-ended systems with water supply from a tank.
2.3 Open-ended systems with direct water-supply (boosted pressure).
The design of the system must ensure that selfemtying of the pump
during standstill is avoided.
The minimum boost pressure is 1 bar atm(14psi) and the maximum
peak pressure is 30 bar (450 psi). The recommended normal boost
pressure is 1-6 bar atm (14-90 psi). Max 10 bar (150 psi) during static
standstill.
The inlet pressure of the pump must never exceed the outlet pressure.
This may typically occur in boosted or open-ended systems
with supply direct from the tap and where a bypass valve is activated.
2.1 Closed water hydraulic systems, water recirculated
(The numbers 1- 3 refer to the drawing below).
In order to eliminate the risk of cavitation, always ensure a positive
inlet pressure by observing the following guidelines:
1)
Place the tank above pump and pump inlet.
2)
Place the main fi lter in the return line and not in the suction line.
3)
Dimension the inlet line with a minimum pressure loss (large
fl ow area, minimum length of pipe, minimum number of bends/
connections, fi ttings with small pressure losses).
521B1096
INSTRUCTIONS
type PAHF 20/25/32/40
Inhalt
1.
Bezeichnung
2.
Systemaufbau
3.
Aufbau der Pumpeneinheit
4.
Erste Inbetriebnahme
5.
Betrieb
6.
Wartung
1. Bezeichnung
2. Systemaufbau
Mögliche Systeme sind:
2.1 Wasserhydrauliksysteme in denen das Wasser in den Tank zurückge-
leitet und wieder verwendet wird.
2.
Off ene Systeme ohne Rückführung mit Versorgung aus einem Tank.
2.3 Off ene Systeme ohne ohne Rückführung, mit direkter Wasserversor-
gung (erhöhter Ansaugdruck).
Der Systemaufbau muß sichern, daß sich die Pumpe im Stillstand
nicht entleert.
Der min. Spitzendruck ist 1 bar atm (14psi) und der Max Spitzen-
druck ist 30 bar (450 psi). Empfohlener Normal-Einlaβdruck ist
1-6 bar atm (14-90 psi). Max 10 bar (150 psi) während statischen
Stillstands
Der Druck am Pumpeneinlaß darf den Druck am Pumpenauslaß
nicht übersteigen. Dies mag typisch in "boosted" oder off enen Systemen
auftreten, die mit Leitungswasser direkt versorgt werden
und in denen ein Bypassventil aktiviert wird.
2.1 Wasserhydrauliksysteme, Wasser rezirkuliert
(Die Nummern 1- 3 beziehen sich auf die unten abgebildete
Zeichnung). Um das Risiko der Kavitation zu verhindern, immer sichern,
daß ein positiver Eingangsdruck vorhanden ist.Befolgen Sie folgende
Richtlinien:
1)
Den Tank über Pumpe und Pumpeneinlaß anbringen.
2)
Das Hauptfi lter möglichst in der Rücklaufl eitung und nicht in der
Saugleitung einbauen.
3)
Die Saugleitung mit einen minimalen Druckverlust dimensionieren
(großer Durchströmungsbereich, minimale Rohrlänge, minimale An-
zahl von Winkelverschraubungen, und Verschraubungen mit klei-
nem Druckverlust).
DKCFN.PI.010.A2.5B
Pump
10-2009

Advertisement

loading

Summary of Contents for Danfoss PAHF 20

  • Page 1 INSTRUCTIONS Pump type PAHF 20/25/32/40 Contents Inhalt Identifi cation Bezeichnung System design Systemaufbau Building up the pump unit Aufbau der Pumpeneinheit Initial start up Erste Inbetriebnahme Operation Betrieb Service Wartung 1. Identification 1. Bezeichnung 2. System design 2. Systemaufbau Systems can be either: Mögliche Systeme sind:...
  • Page 2 Re 2.2 Open-ended systems, water supply from tank 2.2 Off ene Systeme mit Wassertank (The numbers 1- 3 refer to the drawing below) (Die Nummern 1- 3 beziehen sich auf die unten abgebildete Zeichnung) In order to eliminate the risk of cavitation, observe the following Um das Risiko der Kavitation zu vermeiden, befolgen Sie folgende Richt- guidelines: linien:...
  • Page 3 Das Hauptfi lter muß eine Feinheit von 10 μm Abs. ß >5000 The pressure loss across the fi lter should be monitored. haben. Please contact the Danfoss Sales Organization for further fi lter Der Druckverlust über das Filter sollte überwacht werden. details. Nach weiteren Einzelheiten über Filtrierung erkundigen Sie sich bitte bei Ihrer Danfoss Verkaufsorganisation.
  • Page 4 3 mm. A: Elastic coupling / Elastische Kupplung B: Bell housing / Kupplungsgehäuse C: Motor shaft / Motorwelle If alternative mounting is desired, please contact the Danfoss Sales Wünschen Sie eine alternative Montage, fragen Sie bitte Ihre Organization. Danfoss Verkaufsorganisation.
  • Page 5 3.2 Direction of rotation 3.2 Drehrichtung Is indicated by means of an arrow at the inlet side of the pump. Wird durch einen Pfeil seitlich der Einlaßseite der Pumpe angezeigt. CCW (counter clock wise) CW (clock wise) 3.3 Orientation 3.3 Einbaulage The pump can be mounted/orientated in any horizontal position and it Die Pumpe kann in beliebiger horizontaler Position montiert/ausgerich- can be mounted/orientated in the vertical position with the shaft up-...
  • Page 6 Schaltern für Niederdruck und Temperatur. There is one 1/4” port on the outlet for optional mounting of i.e. pres- Ein 1/4” Anschluss an der Auslaβseite für wahlweisen Anschluβ von z.B. einem Druckgeber. sure transducer. PAHF 20/25/32/40 Outlet (O) Inlet (I) Bleeding (C) Gauge Use PAHF adaptor 1 1/4”...
  • Page 7 über Frostschutzmittel verständigen Sie bitte die Danfoss Verkaufs- monopropylene glycol to prevent internal corrosion or frost in the pump. organisation. For further information on anti-freeze media, please contact the Danfoss Sales Organization. Empfohlene Prozedur: 5.6.1 Wasserhydrauliksysteme in denen das Wasser rezirkuliert Recommended procedure: und an den Tank zurückgeleitet wird.
  • Page 8 The pump requires no periodic replacements of seals and valve parts. tilteilen erforderlich. 6.2 Repair 6.2 Reparatur In case of irregular function of the pump, please contact the Bei Funktionsstörungen setzen Sie sich bitte mit Ihrer Danfoss Verkaufs- Danfoss Sales Organisation. organisation in Verbindung.