3 F130 – at your service

Set the ventilation

VENTILATION
Menu 1
This menu is only shown with ex-
haust air installation.
Setting range: normal and speed 1-4
Default value: normal
The ventilation in the accommodation can be temporarily increased or reduced
here.
When a new speed has been selected a countdown is initiated. After 4 hours
the ventilation speed returns to the normal setting.
The fan speed is shown in brackets (in percent) after each speed alternative.
18
Chapter 3 | F130 – at your service
TIP
If longer time changes are required use the holiday function.
Caution
The heat pump requires a minimum ventilation flow in order to work
properly. An insufficient ventilation flow can result in an alarm and
blocking of compressor operation.
normal(70%)
fan speed 1 (30%)
fan speed 2 (50%)
fan speed 3 (70%)
fan speed 4 (90%)