Troubleshooting; Checking Fault Codes (Eh Models Only) - Toro MH-400SH2 Operator's Manual

Material handler, serial no. 401252001 and up
Hide thumbs Also See for MH-400SH2:
Table of Contents

Advertisement

Troubleshooting

Checking Fault Codes (EH Models Only)

If the Diagnostic LED indicates that there is a system fault (refer to
(page
17)), check the fault codes to determine what is wrong with the machine.
Entering Diagnostic Mode and Checking the Codes
1.
Push the E-S
TOP
2.
Pull the tethered cap from the 2 diagnostic shunt connectors
3.
Connect the diagnostic shunt connectors together
4.
Pull the E-
up to turn on the power.
STOP
5.
Count the number of flashes to determine the fault code, then consult the following table:
Note:
If there are multiple faults, both faults will flash, then a long pause, then the flash sequences
will repeat.
button down to turn off the power.
Diagnostic LED Function (EH Model 44954)
(Figure
(Figure
63B).
Figure 63
55
63A).
g028876