Kenwood TK-5400 Series Service Manual page 41

Hide thumbs Also See for TK-5400 Series:
Table of Contents

Advertisement

TK-5400
Item
Condition
8. Battery
1) Set panel tuning mode.
warning
CH : 4 (Center)
level writing
LCD display : BATT
Set DC power supply 6.8V at
battery terminal.
Press [PTT] to show the digit
number.
Press [Orange] key to store
the digit number.
9. Battery
1) Set panel user mode.
warning
BATT terminal voltage : 7.0V
function
PTT : ON
check
2) BATT terminal voltage : 6.6V
PTT : ON
10. SQ1
1) Set user mode.
sensitivity
Frequency : Any
check
Mode : FM
Set the SQ level 1.
11. SQ15
1) Set user mode.
sensitivity
Frequency : Any
check
Mode : FM
Set the SQ level 15.
Note :
Befor the SQ and RSSI adjustment, you need to measure the reference sensitivity at FM wide, NPSPAC, and narrow in order for each adjustment
items to set SSG level.
40
ADJUSTMENT
Measurement
Test-
Unit
Terminal
Unit
equipment
Power meter Panel
ANT
Side
DC VTVM Bottom BATT
terminal
SSG
Panel
ANT
SINAD
Side
Universal
meter
Adjustment
Parts
Method
Orange Writing
6.8V at BATT terminal
Check
Can transmit.
LED (Red) must blink.
Can transmit.
Measure the SINAD Wide : <SINAD 8dB
level where the SQ
NPS : <SINAD 8dB
open continuously.
Narrow : <SINAD 8dB
Wide : >SINAD 18dB
NPS : >SINAD 16dB
Narrow : >SINAD 14dB
Specifications/Remarks

Advertisement

Table of Contents
loading

This manual is also suitable for:

Tk-5400 (k)Tk-5400 (k2)

Table of Contents