Transmitter Section
Item
Condition
1. Frequency
1) Set panel tuning mode.
adjustment
CH : 4 (Center)
LCD display : TXF
PTT : ON
Press [Side 2] to store the
digit number after adjustment.
2. Maximum
1) Set panel tuning mode.
power check
CH : 4 (Center)
BATT terminal voltage : 7.5V
Digit number : 256
LCD display : POW
PTT : ON
3. TX high
1) Set panel tuning mode.
power
CH : 4 (Cener)
adjustment
LCD display : POW
Press [Orange] key to enter
3 point adjustment mode.
LCD display : POW L
PTT : ON
2) Press [Side 2] key.
LCD display : POW C
PTT : ON
3) Press [Side 2] key.
LCD display : POW H
PTT : ON
Press [Side 2] to store the
digit number after adjustment.
4. TX high
1) Set panel tuning mode.
power
CH : 4 (Center)
adjustment
LCD display : POW t
(TA)
Press [Orange] key to ener
3 point adjustment mode.
LCD display : POW tL
PTT : ON
2) Press [Side 2] key.
LCD display : POW tC
PTT : ON
3) Press [Side 2] key.
LCD display : POW tH
PTT : ON
Press [Side 2] to store the
digit number after adjustment.
5. TX low
1) Set panel tuning mode.
power
CH : 4 (Center)
adjustment
LCD display : POW LO
PTT : ON
Press [Side 2] to store the
digit number after adjustment.
6. TX low
1) Set panel tuning mode.
power
CH : 4 (Center)
adjustment
LCD display : POW t LO
(TA)
PTT : ON
Press [Side 2] to store the
digit number after adjustment.
32
ADJUSTMENT
Measurement
Test-
Unit
Terminal
Unit
equipment
Power meter Panel
ANT
Panel
f. counter
Power meter
Ammeter
Panel
Adjustment
Parts
Method
± 100Hz
Top1/
815.500MHz
Top2
Check
>3.5W
± 0.1W
Top1/
3.0W
Top2
± 0.1W
3.0W
± 0.1W
1.0W
Specifications/Remarks