Kenwood TK-5400 Series Service Manual page 37

Hide thumbs Also See for TK-5400 Series:
Table of Contents

Advertisement

TK-5400
Item
Condition
26. TX low
1) Set panel test mode.
power check
CH : 1
at low
Signalling : 1
frequency
Toggle SW : A side
PTT : ON
Press [Side 2] to store the
digit number after adjustment.
27. TX low
1) Set panel test mode.
power check
CH : 7
at high
Signalling : 1
frequency
Toggle SW : A side
PTT : ON
28. TX low
1) Set panel test mode.
power check
CH : 1
at low
Signalling : 1
frequency
Toggle SW : B side
(TA)
PTT : ON
29. TX low
1) Set panel test mode.
power check
CH : 7
at high
Signalling : 1
frequency
Toggle SW : B side
(TA)
PTT : ON
30. APCO low
1) Set panel test mode.
deviation
Mode : AP
check
CH : 4 (Center)
Signalling : 20 (Low deviation
pattern)
Toggle SW : A side
Deviation meter filter setting
LPF : 3kHz
HPF : OFF
De-emphasis : OFF
DET : Peak (+/–)
PTT : ON
31. APCO low
1) Set panel test mode.
deviation
Mode : AP
check (TA)
CH : 4 (Center)
Signalling : 20 (Low deviation
pattern)
Toggle SW : B side
PTT : ON
32. FM
1) Set panel test mode.
NPSPAC
Mode : NP
deviation
CH : 4 (Center)
check
Signalling : 1
Toggle SW : A side
Deviation meter filter setting
LPF : 15kHz
HPF : OFF
De-emphasis : OFF
DET : Peak (+/–)
MIC input : 150mV/1kHz
PTT : ON
36
ADJUSTMENT
Measurement
Test-
Unit
Terminal
Unit
equipment
Power meter Panel
ANT
Ammeter
Deviation
Panel
ANT
meter
Deviation
Panel
ANT
meter
Oscilloscope
AG
Side
Universal
Adjustment
Parts
Method
Check
0.7~1.3W
Check
895~989Hz
Check
3.3kHz± 50Hz
Specifications/Remarks