TK-5400
Item
Condition
40. FM wide
1) Set panel test mode.
MIC
Mode : WD
sensitivity
CH : 1
check
Signalling : 1
Toggle SW : A side
AG input : 1kHz
Deviation meter filter setting
LPF : 15kHz
HPF : OFF
PTT : ON
41. FM wide
1) Set panel test mode.
MIC
Mode : WD
sensitivity
CH : 1
check (TA)
Signalling : 1
Toggle SW : B side
PTT : ON
42. FM
1) Set panel test mode.
NPSPAC
Mode : NP
MIC
CH : 1
sensitivity
Signalling : 1
check
Toggle SW : A side
AG input : 1kHz
Deviation meter filter setting
LPF : 15kHz
HPF : OFF
PTT : ON
43. FM
1) Set panel test mode.
NPSPAC
Mode : NP
MIC
CH : 1
sensitivity
Signalling : 1
check (TA)
Toggle SW : B side
PTT : ON
44. FM narrow 1) Set panel test mode.
MIC
Mode : NR
sensitivity
CH : 1
check
Signalling : 1
Toggle SW : A side
AG input : 1kHz
Deviation meter filter setting
LPF : 15kHz
HPF : OFF
PTT : ON
45. FM narrow 1) Set panel test mode.
MIC
Mode : NR
sensitivity
CH : 1
check (TA)
Signalling : 1
Toggle SW : B side
PTT : ON
38
ADJUSTMENT
Measurement
Test-
Unit
Terminal
Unit
equipment
Deviation
Panel
ANT
meter
Oscilloscope
AG
Side
Universal
Adjustment
Parts
Method
Adjust AG input
15mV± 5mV
level to get a
standard MOD.,
3.0kHz DEV.
Adjust AG input
15mV± 5mV
level to get a
standard MOD.,
2.4kHz DEV.
Adjust AG input
15mV± 5mV
level to get a
standard MOD.,
1.5kHz DEV.