Item
Condition
19. FM narrow 1) Set panel tuning mode
deviation
CH : 4 (Center)
adjustment
LCD display : FMND t LO
(TA)
PTT : ON
Press [Side 2] to store the
digit number after adjustment.
20. QT
1) Set panel tuning mode.
deviation
CH : 4 (Center)
adjustment
LCD display : QTDV LO
Deviation meter filter setting
LPF : 3kHz
HPF : PFF
De-emphasis : OFF
DET : (p-p)/2
PTT : ON
Press [Side 2] to store the
digit number after adjustment.
21. QT
1) Set panel tuning mode.
deviation
CH : 4 (Center)
adjustment
LCD display : QTDV t LO
(TA)
PTT : ON
Press [Side 2] to store the
digit number after adjustment.
22. DQT
1) Set panel tuning mode.
deviation
CH : 4 (Center)
adjustment
LCD display : DQDV LO
Deviation meter filter setting
LPF : 3kHz
HPF : OFF
De-emphasis : OFF
DET : (p-p)/2
PTT : ON
Press [Side 2] to store the
digit number after adjustment.
23. DQT
1) Set panel tuning mode.
deviation
CH : 4 (Center)
adjustment
LCD display : DQDV t LO
(TA)
PTT : ON
Press [Side 2] to store the
digit number after adjustment.
24. DTMF
1) Set panel tuning mode.
deviation
CH : 4 (Center)
adjustment
LCD display : DTDV LO
Deviation meter filter setting
LPF : 15kHz
HPF : PFF
De-emphasis : OFF
PTT : ON
Press [Side 2] to store the
digit number after adjustment.
25. DTMF
1) Set panel tuning mode.
deviation
CH : 4 (Center)
adjustment
LCD display : DTDV t LO
(TA)
PTT : ON
Press [Side 2] to store the
digit number after adjustment.
ADJUSTMENT
Measurement
Test-
Unit
Terminal
Unit
equipment
Deviation
Panel
ANT
Panel
meter
Oscilloscope
AG
Side
Universal
TK-5400
Adjustment
Parts
Method
± 50Hz
Top1/
2.05kHz
Top2
± 0.75kHz
± 50Hz
± 0.75kHz
± 50Hz
± 3.0kHz
± 0.2kHz
Specifications/Remarks
35