Kikusui LIN Series Operation Manual
Kikusui LIN Series Operation Manual

Kikusui LIN Series Operation Manual

Line impedance network
Table of Contents

Advertisement

Quick Links

Operation Manual
Line Impedance Network
LIN Series
LIN1020JF
LIN3020JF
OP01-LIN1020JF
ALARM
LINE IMPEDANCE NETWORK
ALARM
IMPEDANCE SELECT
POWER
POWER
Part No. IB026693
Jun. 2015
LIN1020JF
LINE IMPEDANCE NETWORK
IMPEDANCE SELECT
REMOTE
LIN1020JF
REMOTE
1 General Description
2 Description of Parts
3 Wiring the Test System
4 Wiring the LIN1020JF
5 Wiring the LIN3020JF
6 Operation
7 Remote Control
8 Specifications
Appendix

Advertisement

Table of Contents
loading

Summary of Contents for Kikusui LIN Series

  • Page 1 Part No. IB026693 Jun. 2015 Operation Manual 1 General Description Line Impedance Network LIN Series 2 Description of Parts LIN1020JF 3 Wiring the Test System LIN3020JF 4 Wiring the LIN1020JF OP01-LIN1020JF 5 Wiring the LIN3020JF LIN1020JF LINE IMPEDANCE NETWORK 6 Operation...
  • Page 2: Notations Used In This Guide

    LIN1020JF You can download the most recent version of these manuals LIN3020JF from the Kikusui Electronics Corporation website (http:// OP01-LIN1020JF www.kikusui.co.jp/en/download/). • In this manual, the following AC power supplies are also referred to collectively as the AC power supply.
  • Page 3: Table Of Contents

    Contents Notations used in this guide ....2 LIN1020JF + OP01 + two PCR-LEs: sin- gle-phase and single-phase three-wire 30 Checking the package contents .....5 LIN1020JF + OP01 + three PCR-LEs: sin- Options ..........5 gle-phase and three-phase ..32 Safety markings ........6 LIN1020JF + OP01 + one PCR-LE2: sin- Safety precautions .........6...
  • Page 4 Specifications Appendix A Troubleshooting ..62 Appendix B Connecting the PCR-LE and PCR-LE2... 63 PCR-LE ......64 Output terminal .
  • Page 5: Checking The Package Contents

    • Control power cable (heavy PVC jacketed three-core) during transportation. If something is damaged or missing, This cable is for connecting to contact your Kikusui agent or distributor. We recommend that the control power supply input you save all packing materials, in case the product needs to (AC INPUT) terminal on the be transported at a later date.
  • Page 6: Safety Markings

    • Do not disassemble or modify the product. If you Chassis (frame) terminal. need to modify the product, contact your Kikusui agent or distributor. On (power supply). Maintenance, Inspection and Calibration •...
  • Page 7: Precautions When Choosing The Installation Location

    • Do not install the product on an inclined surface or in a Precautions when choosing the location subject to vibrations. installation location The product may fall or tip over and cause damage and injury. • Lock the casters. Be sure to observe the following precautions Use the caster lock levers to lock the casters.
  • Page 8: Precautions For Moving The Product

    Precautions for moving the product Note the following points when moving the prod- uct to the installation location or when transport- ing the product. • Turn off the POWER switch. Moving the product with the POWER switch turned on may cause electric shock or damage to the product.
  • Page 9: General Description

    General Description This chapter describes the product’s impedance features and impedance construction and provides an overview of the test system. Product Features This product contains JIS- and IEC-compliant impedances required for harmonic and flicker testing of devices connected to power distribution systems. A test system can be configured easily by combining this product with AC power supplies.
  • Page 10: Impedance Construction

    Impedance Construction This product’s impedance consists of resistance, inductance, and short-circuit switch for each phase. The N phase impedance has a switch for selecting between resistance and induc- tance. The following tables contain the defined resistance and inductance values for the U, V, W, and N phases.
  • Page 11: Overview Of The Test System

    Overview of the Test System OP01-LIN1020JF Phase BYPASS 0.19 Ω + 0.23 mH 0.19 Ω + 0.23 mH 0.24 Ω + jn 0.15 Ω Impedance element shorted 0.19 Ω + 0.23 mH 0.19 Ω + 0.23 mH 0.24 Ω + jn 0.15 Ω Resistor Inductance Switch...
  • Page 12: Device Test System

    Overview of the Test System Device test system This section provides a typical example of a device test system using this product. Single-phase 2 kVA: JIS harmonic test, IEC flicker test Component Model and function AC power supply PCR2000LE Impedance LIN1020JF The use of impedance is optional for JIS C61000-3-2(2005) and later.
  • Page 13 Overview of the Test System  A combination of a LIN1020JF and OP01-LIN1020JF PCR-LE LIN1020JF OUTPUT INPUT OUTPUT L(U) L(U) L(U) SENSING SENSING SENSING To the KHA3000 SENSING OP01-LIN1020JF INPUT OUTPUT SENSING SENSING  LIN3020JF PCR-LE LIN3020JF KHA3000 LOAD OUTPUT INPUT OUTPUT SOURCE...
  • Page 14: Grid-Connected Device Test System

    Overview of the Test System Grid-connected device test system This section provides a typical example of a grid-connected device test system using this product. Three-phase 6 kVA: JIS/JET grid-interconnection test Component Model and function AC power supply Three PCR2000LEs Impedance LIN3020JF Power analyzer KHA3000...
  • Page 15: Description Of Parts

    Description of Parts This chapter explains the details of the product’s parts. The descriptions of the terminals of p.63, p.69 the system components, namely the PCR-LE, PCR-LE2, and KHA3000, are provided in the appendixes. LIN1020JF LIN1020JF LINE IMPEDANCE NETWORK ALARM IMPEDANCE SELECT REMOTE WEIGHT APPROX 88kg...
  • Page 16 Description of Parts LIN3020JF LIN3020JF LINE IMPEDANCE NETWORK ALARM IMPEDANCE SELECT REMOTE WEIGHT APPROX 98kg LIN3020JF CONTROL INPUT STATUS OUTPUT CONTROL VOLTAGE SENSING OUTPUT POWER INPUT OUTPUT AC INPUT PHASE VOLTAGE AC300V PHASE VOLTAGE AC300V 100-240V 20A MAX LINE VOLTAGE AC500V LINE VOLTAGE AC500V 50 60Hz 150VA MAX Name...
  • Page 17: Op01-Lin1020Jf

    Description of Parts OP01-LIN1020JF ● The OP01-LIN1020JF is used in combination with the LIN1020JF. It cannot be used by itself. OP01-LIN1020JF LINE IMPEDANCE NETWORK ALARM IMPEDANCE SELECT REMOTE WEIGHT APPROX 83kg OP01-LIN EXPAND VOLTAGE SENSING OUTPUT POWER INPUT OUTPUT AC INPUT PHASE VOLTAGE AC300V PHASE VOLTAGE AC300V 100-240V...
  • Page 18: Input And Output Terminals

    Description of Parts INPUT and OUTPUT terminals The INPUT and OUTPUT terminals are impedance input and output terminals. There is a separate terminal for each phase: U, V, W, and N. The input and output terminals are used according to the test circuit system. The size of the terminal block screws is M6. The nominal cross-sectional area of wires is 22 mm minimum.
  • Page 19: Pcr Control Terminal

    Description of Parts PCR CONTROL terminal LIN1020JF LIN3020JF The PCR CONTROL terminal is available on the LIN1020JF and LIN3020JF. It is a terminal for controlling the AC power supplies. A signal is transmitted when the overheat protection of this product is activated and turns off the AC power supply output. Use the supplied exclusive cable for connecting this terminal.
  • Page 20: Wiring The Test System

    Wiring the Test System This chapter describes how to wire the product to the test system. • Risk of electric shock. For the devices that will be used in the test circuit, be sure WARNING to remove the power cable from the AC power line, turn off the switchboard that the power cable is connected to, and turn off the POWER switch.
  • Page 21: Wiring The Test Circuit

    Wiring the Test Circuit The details of wiring the test circuits are provided in chapter 4 for the LIN1020JF and OP01- p.25, p.37 LIN1020JF and chapter 5 for the LIN3020JF. The test circuits are grouped by the number of AC power supplies (PCR-LEs or PCR-LE2s), and the different input power supply systems (single-phase two-wire, single-phase three-wire, three-phase three-wire, and three-phase four-wire) of the EUT are described.
  • Page 22: Connecting The Control Terminals

    Connecting the Control Terminals Connecting the PCR CONTROL terminal LIN1020JF LIN3020JF The PCR CONTROL terminal is for controlling the AC power supplies. A signal is transmitted when the overheat protection of this product is activated and turns off the AC power supply output.
  • Page 23 Connecting the Control Terminals Connecting the supplied control cable Check that the POWER switches of the LIN-JF and AC power supplies are turned off ( Connect the control cable supplied with the LIN1020JF or LIN3020JF as shown in the following figure. Connect one end of the cable to the connector of the control board that was installed in the AC power supply.
  • Page 24: Connecting The Expand Terminal

    Connecting the Control Terminals Connecting the EXPAND Terminal LIN1020JF OP01-LIN1020JF The EXPAND terminal is used when the LIN1020JF and OP01-LIN1020JF are used in combi- nation to construct a single-phase three-wire test circuit, three-phase three-wire test circuit, or three-phase four-wire test circuit. The OP01 control cable is supplied with the OP01-LIN1020JF.
  • Page 25: Wiring The Lin1020Jf

    Wiring the LIN1020JF This chapter provides wiring diagrams of test circuits that use the LIN1020JF and OP01- LIN1020JF. For general information related to the wiring of test circuits, see chapter 3, “Wiring the Test p.21 Circuit”. The wiring diagrams of test circuits provided in the following pages contains the following types.
  • Page 26: Lin1020Jf + One Pcr-Le: Single-Phase

    Wiring the LIN1020JF LIN1020JF + one PCR-LE: single-phase PCR-LE LIN1020JF 1P2W OUTPUT INPUT OUTPUT L(U) L(U) L(U) SENSING SENSING Nominal cross-sectional area of wires 22 mm 0.75 mm PCR-LE LIN1020JF Single-phase three-wire and three-phase operations require a PCR-LE option. For details, see the PCR-LE manual. VOLTAGE SENSING OUTPUT INPUT OUTPUT...
  • Page 27 AND RATING. SIGNAL I/O (screw size: M6) USER VCC RS232C 40A rms 40A rms 40A rms 40A rms USER GND AC INPUT KIKUSUI ELECTRONICS CORP. STRIP-GAUGE MADE IN JAPAN AWG 24 10mm 100-240V 50-60Hz NB01076-2 250VAMAX EXT SYNC INPUT 5Vpk MAX FUSE 250V2.5A...
  • Page 28: Lin1020Jf + One Pcr-Le2: Single-Phase

    Wiring the LIN1020JF LIN1020JF + one PCR-LE2: single-phase PCR-LE2 LIN1020JF 1P2W OUTPUT INPUT OUTPUT Single phase L(U) L(U) L(U) SENSING SENSING Three-phase Nominal cross- sectional area of wires SENSING 22 mm 0.75 mm LIN1020JF PCR-LE2 VOLTAGE SENSING OUTPUT INPUT OUTPUT PHASE VOLTAGE AC300V PHASE VOLTAGE AC300V 20A MAX...
  • Page 29 AND RATING. SIGNAL I/O (screw size: M6) USER VCC RS232C 40A rms 40A rms 40A rms 40A rms USER GND AC INPUT KIKUSUI ELECTRONICS CORP. STRIP-GAUGE MADE IN JAPAN AWG 24 10mm 100-240V NB01076-2 50-60Hz 250VAMAX EXT SYNC INPUT 5Vpk MAX FUSE 250V2.5A...
  • Page 30: Combination Wiring Of Lin1020Jf And Op01-Lin1020Jf

    Combination Wiring of LIN1020JF and OP01-LIN1020JF LIN1020JF + OP01 + two PCR-LEs: single-phase and single- phase three-wire PCR-LE LIN1020JF 1P2W OUTPUT INPUT OUTPUT 1P3W L(U) L(U) L(U) SENSING SENSING SENSING Nominal cross-sectional area of wires 22 mm 0.75 mm OP01-LIN1020JF PCR-LE Single-phase three-wire and three-phase INPUT...
  • Page 31 FUSE OF THE SPECIFIED TYPE AND RATING. SIGNAL I/O USER VCC RS232C INPUT INPUT INPUT INPUT INPUT USER GND AC INPUT KIKUSUI ELECTRONICS CORP. STRIP-GAUGE AWG 24 10mm MADE IN JAPAN 100-240V 50-60Hz NB01076-2 250VAMAX EXT SYNC INPUT 5Vpk MAX...
  • Page 32: Lin1020Jf + Op01 + Three Pcr-Les: Single-Phase And Three-Phase

    Wiring the LIN1020JF LIN1020JF + OP01 + three PCR-LEs: single-phase and three-phase PCR-LE LIN1020JF 1P2W OUTPUT INPUT OUTPUT 1P3W L(U) L(U) L(U) 3P3W SENSING SENSING 3P4W SENSING SENSING Nominal cross-sectional area of wires 22 mm 0.75 mm OP01-LIN1020JF PCR-LE Single-phase three-wire and three-phase operations INPUT OUTPUT require a PCR-LE option.
  • Page 33 FUSE OF THE SPECIFIED TYPE AND RATING. SIGNAL I/O USER VCC RS232C INPUT INPUT INPUT INPUT INPUT USER GND AC INPUT KIKUSUI ELECTRONICS CORP. STRIP-GAUGE MADE IN JAPAN AWG 24 10mm 100-240V 50-60Hz NB01076-2 250VAMAX EXT SYNC INPUT 5Vpk MAX...
  • Page 34: Lin1020Jf + Op01 + One Pcr-Le2: Single-Phase And Three-Phase

    Wiring the LIN1020JF LIN1020JF + OP01 + one PCR-LE2: single-phase and three-phase PCR-LE2 LIN1020JF 1P2W OUTPUT INPUT OUTPUT 1P3W Single phase L(U) L(U) L(U) 3P3W SENSING 3P4W SENSING Three-phase Nominal cross-sectional area of wires SENSING 22 mm OP01-LIN1020JF 0.75 mm INPUT OUTPUT SENSING...
  • Page 35 FUSE OF THE SPECIFIED TYPE AND RATING. SIGNAL I/O USER VCC RS232C INPUT INPUT INPUT INPUT INPUT USER GND AC INPUT KIKUSUI ELECTRONICS CORP. STRIP-GAUGE MADE IN JAPAN AWG 24 10mm 100-240V 50-60Hz NB01076-2 250VAMAX EXT SYNC INPUT 5Vpk MAX...
  • Page 36 Wiring the LIN1020JF This page has been intentionally left blank. LIN-JF...
  • Page 37: Wiring The Lin3020Jf

    Wiring the LIN3020JF This chapter provides wiring diagrams of test circuits that use the LIN3020JF. For general information related to the wiring of test circuits, see chapter 3, “Wiring the Test p.21 Circuit”. The wiring diagrams of test circuits provided in the following pages contains the following types.
  • Page 38: Lin3020Jf + One Pcr-Le: Single-Phase

    Wiring the LIN3020JF LIN3020JF + one PCR-LE: single-phase PCR-LE LIN3020JF 1P2W INPUT OUTPUT OUTPUT SENSING SENSING SENSING SENSING Nominal cross-sectional area of wires 22 mm 0.75 mm PCR-LE Single-phase three-wire and three-phase operations require a PCR-LE option. LIN3020JF For details, see the PCR-LE manual. VOLTAGE SENSING OUTPUT INPUT OUTPUT...
  • Page 39: Wiring The Lin3020Jf

    AND RATING. SIGNAL I/O (screw size: M6) USER VCC RS232C 40A rms 40A rms 40A rms 40A rms USER GND AC INPUT KIKUSUI ELECTRONICS CORP. STRIP-GAUGE MADE IN JAPAN AWG 24 10mm 100-240V 50-60Hz NB01076-2 250VAMAX EXT SYNC INPUT 5Vpk MAX FUSE 250V2.5A...
  • Page 40: Lin3020Jf + Two Pcr-Le: Single-Phase And Single-Phase Three-Wire

    Wiring the LIN3020JF LIN3020JF + two PCR-LE: single-phase and single-phase three-wire PCR-LE LIN3020JF 1P2W OUTPUT INPUT OUTPUT 1P3W SENSING SENSING SENSING SENSING SENSING Nominal cross-sectional area of wires 22 mm 0.75 mm PCR-LE LIN3020JF Single-phase three-wire and three-phase operations require a PCR-LE option. VOLTAGE SENSING OUTPUT For details, see the PCR-LE manual.
  • Page 41 AND RATING. SIGNAL I/O (screw size: M6) USER VCC RS232C 40A rms 40A rms 40A rms 40A rms USER GND AC INPUT KIKUSUI ELECTRONICS CORP. STRIP-GAUGE MADE IN JAPAN AWG 24 10mm 100-240V 50-60Hz NB01076-2 250VAMAX EXT SYNC INPUT 5Vpk MAX FUSE 250V2.5A...
  • Page 42: Lin3020Jf + Three Pcr-Les: Single-Phase And Three-Phase

    Wiring the LIN3020JF LIN3020JF + three PCR-LEs: single-phase and three-phase PCR-LE LIN3020JF 1P2W OUTPUT INPUT OUTPUT 1P3W 3P3W SENSING SENSING 3P4W SENSING SENSING SENSING SENSING Nominal cross-sectional area of wires 22 mm 0.75 mm PCR-LE LIN3020JF Single-phase three-wire and three-phase operations require a PCR-LE option.
  • Page 43 AND RATING. SIGNAL I/O (screw size: M6) USER VCC RS232C 40A rms 40A rms 40A rms 40A rms USER GND AC INPUT KIKUSUI ELECTRONICS CORP. STRIP-GAUGE AWG 24 10mm MADE IN JAPAN 100-240V 50-60Hz NB01076-2 250VAMAX EXT SYNC INPUT 5Vpk MAX FUSE 250V2.5A...
  • Page 44: Lin3020Jf + One Pcr-Le2: Single-Phase

    Wiring the LIN3020JF LIN3020JF + one PCR-LE2: single-phase PCR-LE2 LIN3020JF 1P2W OUTPUT INPUT OUTPUT Single phase SENSING SENSING SENSING Three-phase SENSING Nominal cross-sectional area of wires SENSING 22 mm 0.75 mm LIN3020JF PCR-LE2 VOLTAGE SENSING OUTPUT INPUT OUTPUT PHASE VOLTAGE AC300V PHASE VOLTAGE AC300V 20A MAX LINE VOLTAGE AC500V...
  • Page 45 AND RATING. SIGNAL I/O (screw size: M6) USER VCC RS232C 40A rms 40A rms 40A rms 40A rms USER GND AC INPUT KIKUSUI ELECTRONICS CORP. STRIP-GAUGE AWG 24 10mm MADE IN JAPAN 100-240V 50-60Hz NB01076-2 250VAMAX EXT SYNC INPUT 5Vpk MAX FUSE 250V2.5A...
  • Page 46: Lin3020Jf + One Pcr-Le2: Single-Phase And Three-Phase

    Wiring the LIN3020JF LIN3020JF + one PCR-LE2: single-phase and three-phase PCR-LE2 LIN3020JF 1P2W OUTPUT INPUT OUTPUT 1P3W Single-phase 3P3W SENSING 3P4W SENSING SENSING Three-phase SENSING Nominal cross-sectional area of wires SENSING 22 mm 0.75 mm LIN3020JF PCR-LE2 VOLTAGE SENSING OUTPUT INPUT OUTPUT PHASE VOLTAGE AC300V...
  • Page 47 AND RATING. SIGNAL I/O (screw size: M6) USER VCC RS232C 40A rms 40A rms 40A rms 40A rms USER GND AC INPUT KIKUSUI ELECTRONICS CORP. STRIP-GAUGE MADE IN JAPAN AWG 24 10mm 100-240V 50-60Hz NB01076-2 250VAMAX EXT SYNC INPUT 5Vpk MAX FUSE 250V2.5A...
  • Page 48: Operation

    Operation This chapter describes how to turn on the product, how to select the impedance, and how to handle alarms. Powering On Turning on the POWER switch Turn on the POWER switch of this product. The power indicator turns on, and the cooling fan starts running. Panel Operation LIN1020JF LIN3020JF...
  • Page 49: Configuring The Ac Power Supplies

    Configuring the AC Power Supplies  Operation example The following procedure is for switching from Z1 to Z2. Press Z2. The Z1 and Z2 illumination areas turn on. Both impedance switches are on in this con- dition. Press Z1. The Z1 illumination area turns off, leaving only Z2 selected. Configuring the AC Power Supplies The configuration of the AC power supplies provided below is necessary when using this product.
  • Page 50: Output Current Limit Of The Ac Power Supplies

    Configuring the KHA3000 Output current limit of the AC power supplies The maximum rated current of this product is 20 Arms (continuous). • To ensure safety of this product and EUT, set the output current of the AC power supplies to CAUTION 20 A or less.
  • Page 51: Handling Overheat Alarms

    Handling Overheat Alarms When the overheat protection function of this product is activated, the internal phase circuits are opened, shutting off the current. If the PCR CONTROL terminal function is used, the AC power supply output can also be turned off when the overheat protection function is activated. The detailed operation is described below.
  • Page 52: Remote Control

    Remote Control This chapter describes how to use remote control through the CONTROL INPUT terminal or USB. In this manual, contact signal control refers to the notion of remote control using the CONTROL INPUT terminal. Switching to Remote Control Mode Switching between panel control and remote control You can select the impedance from the front panel or through remote control.
  • Page 53: Controlling The Product Using Contact Signals

    Controlling the Product Using Contact Signals You can use an external sequencer contact signal output or a digital I/O controller through the CONTROL INPUT terminal to select the product’s impedance. You can use the STATUS OUTPUT terminal to check the product status. CONTROL INPUT terminal LIN1020JF LIN3020JF...
  • Page 54 Controlling the Product Using Contact Signals ● LIN OVERHEAT (overheat alarm) This status signal is transmitted when the product’s internal overheat protection function is activated. It is used to control external devices. • REMOTE/LOCAL: This status signal indicates that the product is operating in remote mode.
  • Page 55: Controlling The Product Using Usb

    Controlling the Product Using USB CONTROL INPUT terminal STATUS OUTPUT terminal Isolated digital I/O terminal O-NC I-PC O-NC I-PC O-07 I-00 O-06 I-01 O-05 I-02 O-04 I-03 O-03 I-04 O-02 I-05 O-01 I-06 O-00 I-07 O-PC O-PC Interface connector (Connect to a PC’s USB port) Connectors CN1 and CN2 are screw terminal blocks.
  • Page 56: Installing The Driver

    Controlling the Product Using USB  Using the USB port and CONTROL INPUT terminal simultaneously In remote control through the USB port, the control signal from the CN1 terminal (see the fig- p.54 ure on the previous page) is connected to the product’s CONTROL INPUT terminal. The out- put from the CN1 terminal is an open-collector circuit.
  • Page 57 Controlling the Product Using USB Starting the diagnosis program On your PC, choose Computer, Properties, and then Device Manager. “CONTEC Devices” appears in the Device Manager window. Right-click CONTEC Devices-DIO DIO-0808LY-USB, and then click Prop- erties. DIO DIO-0808LY-USB “DIO1000” Properties appear. Click Diagnosis on the Common Settings tab.
  • Page 58 Controlling the Product Using USB Checking the output port operation By controlling specific bits, you can check whether the impedance can be switched properly. Output port Click the bits in the output port to change the internal I/O port output. To switch the imped- ance, set the appropriate bits by referring to the following table.
  • Page 59 Specifications This chapter lists the electrical and mechanical specifications of the product. Item LIN1020JF LIN3020JF OP01-LIN1020JF JIS C61000-3-2(2011), JETGR0003-1-2.0(2011), JIS C8962(2008), Compliant standards IEC 61000-3-3(2008) Single-phase two-wire Single-phase two- Single-phase three- (Single-phase three- wire, single-phase wire, three-phase wire, three-phase three-wire, three- three-wire, and three- three-wire, and three- phase three-wire, and...
  • Page 60 Specifications Item LIN1020JF LIN3020JF OP01-LIN1020JF Control output to the Control input from the OP01-LIN1020JF, OP01-LIN1020JF control LIN1020JF, alarm out- alarm input from the Not available put to the LIN1020JF OP01-LIN1020JF I/O terminal Dsub25P Dsub25P Control features When abnormal resistor temperature is detected, the ALARM indica- Protection functions tor lights, a make contact signal is transmitted to turn off (open) all phases at once.
  • Page 61 Specifications 300 (11.8) 4-Φ14 4-M10 MAX485 (MAX19.1) 570 (22.4) 460 (18.1) (1.57) (1.57) 430 (16.9) 650 (25.6) 4-M5 400 (15.7) 150 (5.91) 250 (9.84) 150 (5.91) (1.97) (1.97) Unit: mm (inches) LIN1020JF, LIN3020JF, OP01-LIN1020JF outline drawing LIN-JF...
  • Page 62: Troubleshooting

    Appendix A Troubleshooting This section introduces troubleshooting measures. Check whether any of the items listed below apply to your case. If following the remedy does not solve your problem, contact your Kikusui agent or distributor. Symptom Inspection Remedy Voltage is not The product’s POWER switch...
  • Page 63: Connecting The Pcr-Le And Pcr-Le2

    Appendix B Connecting the PCR-LE and PCR-LE2 This section describes how to use the output terminal of the PCR-LE and PCR-LE2 AC power supplies. The following description is for connecting the AC power supplies to the LIN-JF. For other details, see the PCR-LE or PCR-LE2 manual. Risk of electric shock.
  • Page 64: Pcr-Le

    PCR-LE Output terminal The screw size of the output terminal block varies depending on the model. Terminal block screw size Model Single-phase output PCR1000LE PCR2000LE PCR3000LE PCR4000LE PCR6000LE PCR9000LE Single-phase two-wire output Pull out the OUTPUT Terminal block from the bottom of the AC power supply’s rear panel.
  • Page 65: Sensing

    Connecting the PCR-LE and PCR-LE2 Connect the AC power supply’s OUTPUT Terminal to the LIN-JF input terminal. The following figures show a connection example. OUTPUT terminal block G N L LIN1020JF input terminal Sensing The sensing functions that are equipped in the PCR-LE and PCR-LE2 series can be used to reduce the effects of output terminal wiring impedance.
  • Page 66: Pcr-Le2

    PCR-LE2 This section describes the PCR6000LE2 and PCR9000LE2. For details on the PCR27000LE2, see the PCR-LE2 series AC power supply setup guide or user’s manual. Output terminal The screw size of the output terminal block varies depending on the model. Terminal block screw size Model...
  • Page 67 Connecting the PCR-LE and PCR-LE2 M4 x 2 Stopper Connect the AC power supply’s OUTPUT Terminal to the LIN-JF input terminal. The connection to the AC power supply OUTPUT terminal is shown in a figure on the next page. Single-phase two-wire output Single-phase three-wire, three-phase three-wire, and three-phase four-wire output Pull out the OUTPUT Terminal block from the bottom of the AC power...
  • Page 68: Sensing

    Connecting the PCR-LE and PCR-LE2 Single-phase Three-phase three-wire output output Sensing The sensing functions that are equipped in the PCR-LE and PCR-LE2 series can be used to reduce the effects of output terminal wiring impedance. This simplifies the wiring when they are incorporated in the test system.
  • Page 69: Kha3000 Input Terminal

    Appendix C KHA3000 Input Terminal This section describes how to use the KHA3000 input terminal. One phase (input channel) is described. For details on each phase, see the KHA3000 operation manual. Voltage input terminal Use input terminal V and input terminal ± to connect to the EUT. We recommend that you use UL1015 wires or equivalent with a wire size of AWG18.
  • Page 70: Mation)

    KHA3000 Input Terminal Delta transformation (star-delta transformation) The delta transformation feature is used to convert phase voltage measurements of three- phase four-wire circuits to line voltages. Therefore, even if the actual circuit is wired using a three-phase four-wire system, line voltage measurement of a three-phase three-wire system is possible.
  • Page 71 Index AC INPUT ..........15 temperature range in which specifications are guaran- AC power supplies that can be used ....... 21 teed ..............60 ALARM indicator ......... 15 test circuit ..............21 base hold angle ............7 USB ..............15 BYPASS ..........15 USB port ............19 caster lock lever ............
  • Page 72 环境保护使用期限 Environment-friendly Use Period 该标记为适用于在中华人民共和国销售的电子信息产品的环境保护使用 期限。 只要遵守有关该产品的安全及使用注意事项,从制造年月起计算,在该 年度内,就不会对环境污染、人身、财产产生重大的影响。 产品的废弃请遵守有关规定。 产品的制造年月可以在以下网址中确认。 http://www.kikusui.co.jp/pi/ 有毒有害物质或元素名称及含有标示 Name of hazardous materials and symbol of element in the equipment and quantity 有毒有害物质或元素 部件名称 铅 汞 镉 六价铬 多溴联苯 多溴二苯醚 PBDE Cr(VI) 印刷电路板组装品 内部接线 外壳 底盘组装品(含变压器) 辅助设备...
  • Page 74 In either case, please contact your Kikusui agent or distributor. At that time, inform your agent or distributor of the “Part No.” written on the front cover of this manual.

This manual is also suitable for:

Lin1020jfLin3020jfOp01-lin1020jf