Page 1
Part No. IB026693 Jun. 2015 Operation Manual 1 General Description Line Impedance Network LIN Series 2 Description of Parts LIN1020JF 3 Wiring the Test System LIN3020JF 4 Wiring the LIN1020JF OP01-LIN1020JF 5 Wiring the LIN3020JF LIN1020JF LINE IMPEDANCE NETWORK 6 Operation...
LIN1020JF You can download the most recent version of these manuals LIN3020JF from the Kikusui Electronics Corporation website (http:// OP01-LIN1020JF www.kikusui.co.jp/en/download/). • In this manual, the following AC power supplies are also referred to collectively as the AC power supply.
• Control power cable (heavy PVC jacketed three-core) during transportation. If something is damaged or missing, This cable is for connecting to contact your Kikusui agent or distributor. We recommend that the control power supply input you save all packing materials, in case the product needs to (AC INPUT) terminal on the be transported at a later date.
• Do not disassemble or modify the product. If you Chassis (frame) terminal. need to modify the product, contact your Kikusui agent or distributor. On (power supply). Maintenance, Inspection and Calibration •...
• Do not install the product on an inclined surface or in a Precautions when choosing the location subject to vibrations. installation location The product may fall or tip over and cause damage and injury. • Lock the casters. Be sure to observe the following precautions Use the caster lock levers to lock the casters.
Precautions for moving the product Note the following points when moving the prod- uct to the installation location or when transport- ing the product. • Turn off the POWER switch. Moving the product with the POWER switch turned on may cause electric shock or damage to the product.
General Description This chapter describes the product’s impedance features and impedance construction and provides an overview of the test system. Product Features This product contains JIS- and IEC-compliant impedances required for harmonic and flicker testing of devices connected to power distribution systems. A test system can be configured easily by combining this product with AC power supplies.
Impedance Construction This product’s impedance consists of resistance, inductance, and short-circuit switch for each phase. The N phase impedance has a switch for selecting between resistance and induc- tance. The following tables contain the defined resistance and inductance values for the U, V, W, and N phases.
Overview of the Test System Device test system This section provides a typical example of a device test system using this product. Single-phase 2 kVA: JIS harmonic test, IEC flicker test Component Model and function AC power supply PCR2000LE Impedance LIN1020JF The use of impedance is optional for JIS C61000-3-2(2005) and later.
Page 13
Overview of the Test System A combination of a LIN1020JF and OP01-LIN1020JF PCR-LE LIN1020JF OUTPUT INPUT OUTPUT L(U) L(U) L(U) SENSING SENSING SENSING To the KHA3000 SENSING OP01-LIN1020JF INPUT OUTPUT SENSING SENSING LIN3020JF PCR-LE LIN3020JF KHA3000 LOAD OUTPUT INPUT OUTPUT SOURCE...
Overview of the Test System Grid-connected device test system This section provides a typical example of a grid-connected device test system using this product. Three-phase 6 kVA: JIS/JET grid-interconnection test Component Model and function AC power supply Three PCR2000LEs Impedance LIN3020JF Power analyzer KHA3000...
Description of Parts This chapter explains the details of the product’s parts. The descriptions of the terminals of p.63, p.69 the system components, namely the PCR-LE, PCR-LE2, and KHA3000, are provided in the appendixes. LIN1020JF LIN1020JF LINE IMPEDANCE NETWORK ALARM IMPEDANCE SELECT REMOTE WEIGHT APPROX 88kg...
Page 16
Description of Parts LIN3020JF LIN3020JF LINE IMPEDANCE NETWORK ALARM IMPEDANCE SELECT REMOTE WEIGHT APPROX 98kg LIN3020JF CONTROL INPUT STATUS OUTPUT CONTROL VOLTAGE SENSING OUTPUT POWER INPUT OUTPUT AC INPUT PHASE VOLTAGE AC300V PHASE VOLTAGE AC300V 100-240V 20A MAX LINE VOLTAGE AC500V LINE VOLTAGE AC500V 50 60Hz 150VA MAX Name...
Description of Parts OP01-LIN1020JF ● The OP01-LIN1020JF is used in combination with the LIN1020JF. It cannot be used by itself. OP01-LIN1020JF LINE IMPEDANCE NETWORK ALARM IMPEDANCE SELECT REMOTE WEIGHT APPROX 83kg OP01-LIN EXPAND VOLTAGE SENSING OUTPUT POWER INPUT OUTPUT AC INPUT PHASE VOLTAGE AC300V PHASE VOLTAGE AC300V 100-240V...
Description of Parts INPUT and OUTPUT terminals The INPUT and OUTPUT terminals are impedance input and output terminals. There is a separate terminal for each phase: U, V, W, and N. The input and output terminals are used according to the test circuit system. The size of the terminal block screws is M6. The nominal cross-sectional area of wires is 22 mm minimum.
Description of Parts PCR CONTROL terminal LIN1020JF LIN3020JF The PCR CONTROL terminal is available on the LIN1020JF and LIN3020JF. It is a terminal for controlling the AC power supplies. A signal is transmitted when the overheat protection of this product is activated and turns off the AC power supply output. Use the supplied exclusive cable for connecting this terminal.
Wiring the Test System This chapter describes how to wire the product to the test system. • Risk of electric shock. For the devices that will be used in the test circuit, be sure WARNING to remove the power cable from the AC power line, turn off the switchboard that the power cable is connected to, and turn off the POWER switch.
Wiring the Test Circuit The details of wiring the test circuits are provided in chapter 4 for the LIN1020JF and OP01- p.25, p.37 LIN1020JF and chapter 5 for the LIN3020JF. The test circuits are grouped by the number of AC power supplies (PCR-LEs or PCR-LE2s), and the different input power supply systems (single-phase two-wire, single-phase three-wire, three-phase three-wire, and three-phase four-wire) of the EUT are described.
Connecting the Control Terminals Connecting the PCR CONTROL terminal LIN1020JF LIN3020JF The PCR CONTROL terminal is for controlling the AC power supplies. A signal is transmitted when the overheat protection of this product is activated and turns off the AC power supply output.
Page 23
Connecting the Control Terminals Connecting the supplied control cable Check that the POWER switches of the LIN-JF and AC power supplies are turned off ( Connect the control cable supplied with the LIN1020JF or LIN3020JF as shown in the following figure. Connect one end of the cable to the connector of the control board that was installed in the AC power supply.
Connecting the Control Terminals Connecting the EXPAND Terminal LIN1020JF OP01-LIN1020JF The EXPAND terminal is used when the LIN1020JF and OP01-LIN1020JF are used in combi- nation to construct a single-phase three-wire test circuit, three-phase three-wire test circuit, or three-phase four-wire test circuit. The OP01 control cable is supplied with the OP01-LIN1020JF.
Wiring the LIN1020JF This chapter provides wiring diagrams of test circuits that use the LIN1020JF and OP01- LIN1020JF. For general information related to the wiring of test circuits, see chapter 3, “Wiring the Test p.21 Circuit”. The wiring diagrams of test circuits provided in the following pages contains the following types.
Wiring the LIN1020JF LIN1020JF + one PCR-LE: single-phase PCR-LE LIN1020JF 1P2W OUTPUT INPUT OUTPUT L(U) L(U) L(U) SENSING SENSING Nominal cross-sectional area of wires 22 mm 0.75 mm PCR-LE LIN1020JF Single-phase three-wire and three-phase operations require a PCR-LE option. For details, see the PCR-LE manual. VOLTAGE SENSING OUTPUT INPUT OUTPUT...
Page 27
AND RATING. SIGNAL I/O (screw size: M6) USER VCC RS232C 40A rms 40A rms 40A rms 40A rms USER GND AC INPUT KIKUSUI ELECTRONICS CORP. STRIP-GAUGE MADE IN JAPAN AWG 24 10mm 100-240V 50-60Hz NB01076-2 250VAMAX EXT SYNC INPUT 5Vpk MAX FUSE 250V2.5A...
Wiring the LIN1020JF LIN1020JF + one PCR-LE2: single-phase PCR-LE2 LIN1020JF 1P2W OUTPUT INPUT OUTPUT Single phase L(U) L(U) L(U) SENSING SENSING Three-phase Nominal cross- sectional area of wires SENSING 22 mm 0.75 mm LIN1020JF PCR-LE2 VOLTAGE SENSING OUTPUT INPUT OUTPUT PHASE VOLTAGE AC300V PHASE VOLTAGE AC300V 20A MAX...
Page 29
AND RATING. SIGNAL I/O (screw size: M6) USER VCC RS232C 40A rms 40A rms 40A rms 40A rms USER GND AC INPUT KIKUSUI ELECTRONICS CORP. STRIP-GAUGE MADE IN JAPAN AWG 24 10mm 100-240V NB01076-2 50-60Hz 250VAMAX EXT SYNC INPUT 5Vpk MAX FUSE 250V2.5A...
Combination Wiring of LIN1020JF and OP01-LIN1020JF LIN1020JF + OP01 + two PCR-LEs: single-phase and single- phase three-wire PCR-LE LIN1020JF 1P2W OUTPUT INPUT OUTPUT 1P3W L(U) L(U) L(U) SENSING SENSING SENSING Nominal cross-sectional area of wires 22 mm 0.75 mm OP01-LIN1020JF PCR-LE Single-phase three-wire and three-phase INPUT...
Page 31
FUSE OF THE SPECIFIED TYPE AND RATING. SIGNAL I/O USER VCC RS232C INPUT INPUT INPUT INPUT INPUT USER GND AC INPUT KIKUSUI ELECTRONICS CORP. STRIP-GAUGE AWG 24 10mm MADE IN JAPAN 100-240V 50-60Hz NB01076-2 250VAMAX EXT SYNC INPUT 5Vpk MAX...
Wiring the LIN1020JF LIN1020JF + OP01 + three PCR-LEs: single-phase and three-phase PCR-LE LIN1020JF 1P2W OUTPUT INPUT OUTPUT 1P3W L(U) L(U) L(U) 3P3W SENSING SENSING 3P4W SENSING SENSING Nominal cross-sectional area of wires 22 mm 0.75 mm OP01-LIN1020JF PCR-LE Single-phase three-wire and three-phase operations INPUT OUTPUT require a PCR-LE option.
Page 33
FUSE OF THE SPECIFIED TYPE AND RATING. SIGNAL I/O USER VCC RS232C INPUT INPUT INPUT INPUT INPUT USER GND AC INPUT KIKUSUI ELECTRONICS CORP. STRIP-GAUGE MADE IN JAPAN AWG 24 10mm 100-240V 50-60Hz NB01076-2 250VAMAX EXT SYNC INPUT 5Vpk MAX...
Wiring the LIN1020JF LIN1020JF + OP01 + one PCR-LE2: single-phase and three-phase PCR-LE2 LIN1020JF 1P2W OUTPUT INPUT OUTPUT 1P3W Single phase L(U) L(U) L(U) 3P3W SENSING 3P4W SENSING Three-phase Nominal cross-sectional area of wires SENSING 22 mm OP01-LIN1020JF 0.75 mm INPUT OUTPUT SENSING...
Page 35
FUSE OF THE SPECIFIED TYPE AND RATING. SIGNAL I/O USER VCC RS232C INPUT INPUT INPUT INPUT INPUT USER GND AC INPUT KIKUSUI ELECTRONICS CORP. STRIP-GAUGE MADE IN JAPAN AWG 24 10mm 100-240V 50-60Hz NB01076-2 250VAMAX EXT SYNC INPUT 5Vpk MAX...
Page 36
Wiring the LIN1020JF This page has been intentionally left blank. LIN-JF...
Wiring the LIN3020JF This chapter provides wiring diagrams of test circuits that use the LIN3020JF. For general information related to the wiring of test circuits, see chapter 3, “Wiring the Test p.21 Circuit”. The wiring diagrams of test circuits provided in the following pages contains the following types.
Wiring the LIN3020JF LIN3020JF + one PCR-LE: single-phase PCR-LE LIN3020JF 1P2W INPUT OUTPUT OUTPUT SENSING SENSING SENSING SENSING Nominal cross-sectional area of wires 22 mm 0.75 mm PCR-LE Single-phase three-wire and three-phase operations require a PCR-LE option. LIN3020JF For details, see the PCR-LE manual. VOLTAGE SENSING OUTPUT INPUT OUTPUT...
AND RATING. SIGNAL I/O (screw size: M6) USER VCC RS232C 40A rms 40A rms 40A rms 40A rms USER GND AC INPUT KIKUSUI ELECTRONICS CORP. STRIP-GAUGE MADE IN JAPAN AWG 24 10mm 100-240V 50-60Hz NB01076-2 250VAMAX EXT SYNC INPUT 5Vpk MAX FUSE 250V2.5A...
Wiring the LIN3020JF LIN3020JF + two PCR-LE: single-phase and single-phase three-wire PCR-LE LIN3020JF 1P2W OUTPUT INPUT OUTPUT 1P3W SENSING SENSING SENSING SENSING SENSING Nominal cross-sectional area of wires 22 mm 0.75 mm PCR-LE LIN3020JF Single-phase three-wire and three-phase operations require a PCR-LE option. VOLTAGE SENSING OUTPUT For details, see the PCR-LE manual.
Page 41
AND RATING. SIGNAL I/O (screw size: M6) USER VCC RS232C 40A rms 40A rms 40A rms 40A rms USER GND AC INPUT KIKUSUI ELECTRONICS CORP. STRIP-GAUGE MADE IN JAPAN AWG 24 10mm 100-240V 50-60Hz NB01076-2 250VAMAX EXT SYNC INPUT 5Vpk MAX FUSE 250V2.5A...
Wiring the LIN3020JF LIN3020JF + three PCR-LEs: single-phase and three-phase PCR-LE LIN3020JF 1P2W OUTPUT INPUT OUTPUT 1P3W 3P3W SENSING SENSING 3P4W SENSING SENSING SENSING SENSING Nominal cross-sectional area of wires 22 mm 0.75 mm PCR-LE LIN3020JF Single-phase three-wire and three-phase operations require a PCR-LE option.
Page 43
AND RATING. SIGNAL I/O (screw size: M6) USER VCC RS232C 40A rms 40A rms 40A rms 40A rms USER GND AC INPUT KIKUSUI ELECTRONICS CORP. STRIP-GAUGE AWG 24 10mm MADE IN JAPAN 100-240V 50-60Hz NB01076-2 250VAMAX EXT SYNC INPUT 5Vpk MAX FUSE 250V2.5A...
Wiring the LIN3020JF LIN3020JF + one PCR-LE2: single-phase PCR-LE2 LIN3020JF 1P2W OUTPUT INPUT OUTPUT Single phase SENSING SENSING SENSING Three-phase SENSING Nominal cross-sectional area of wires SENSING 22 mm 0.75 mm LIN3020JF PCR-LE2 VOLTAGE SENSING OUTPUT INPUT OUTPUT PHASE VOLTAGE AC300V PHASE VOLTAGE AC300V 20A MAX LINE VOLTAGE AC500V...
Page 45
AND RATING. SIGNAL I/O (screw size: M6) USER VCC RS232C 40A rms 40A rms 40A rms 40A rms USER GND AC INPUT KIKUSUI ELECTRONICS CORP. STRIP-GAUGE AWG 24 10mm MADE IN JAPAN 100-240V 50-60Hz NB01076-2 250VAMAX EXT SYNC INPUT 5Vpk MAX FUSE 250V2.5A...
Wiring the LIN3020JF LIN3020JF + one PCR-LE2: single-phase and three-phase PCR-LE2 LIN3020JF 1P2W OUTPUT INPUT OUTPUT 1P3W Single-phase 3P3W SENSING 3P4W SENSING SENSING Three-phase SENSING Nominal cross-sectional area of wires SENSING 22 mm 0.75 mm LIN3020JF PCR-LE2 VOLTAGE SENSING OUTPUT INPUT OUTPUT PHASE VOLTAGE AC300V...
Page 47
AND RATING. SIGNAL I/O (screw size: M6) USER VCC RS232C 40A rms 40A rms 40A rms 40A rms USER GND AC INPUT KIKUSUI ELECTRONICS CORP. STRIP-GAUGE MADE IN JAPAN AWG 24 10mm 100-240V 50-60Hz NB01076-2 250VAMAX EXT SYNC INPUT 5Vpk MAX FUSE 250V2.5A...
Operation This chapter describes how to turn on the product, how to select the impedance, and how to handle alarms. Powering On Turning on the POWER switch Turn on the POWER switch of this product. The power indicator turns on, and the cooling fan starts running. Panel Operation LIN1020JF LIN3020JF...
Configuring the AC Power Supplies Operation example The following procedure is for switching from Z1 to Z2. Press Z2. The Z1 and Z2 illumination areas turn on. Both impedance switches are on in this con- dition. Press Z1. The Z1 illumination area turns off, leaving only Z2 selected. Configuring the AC Power Supplies The configuration of the AC power supplies provided below is necessary when using this product.
Configuring the KHA3000 Output current limit of the AC power supplies The maximum rated current of this product is 20 Arms (continuous). • To ensure safety of this product and EUT, set the output current of the AC power supplies to CAUTION 20 A or less.
Handling Overheat Alarms When the overheat protection function of this product is activated, the internal phase circuits are opened, shutting off the current. If the PCR CONTROL terminal function is used, the AC power supply output can also be turned off when the overheat protection function is activated. The detailed operation is described below.
Remote Control This chapter describes how to use remote control through the CONTROL INPUT terminal or USB. In this manual, contact signal control refers to the notion of remote control using the CONTROL INPUT terminal. Switching to Remote Control Mode Switching between panel control and remote control You can select the impedance from the front panel or through remote control.
Controlling the Product Using Contact Signals You can use an external sequencer contact signal output or a digital I/O controller through the CONTROL INPUT terminal to select the product’s impedance. You can use the STATUS OUTPUT terminal to check the product status. CONTROL INPUT terminal LIN1020JF LIN3020JF...
Page 54
Controlling the Product Using Contact Signals ● LIN OVERHEAT (overheat alarm) This status signal is transmitted when the product’s internal overheat protection function is activated. It is used to control external devices. • REMOTE/LOCAL: This status signal indicates that the product is operating in remote mode.
Controlling the Product Using USB CONTROL INPUT terminal STATUS OUTPUT terminal Isolated digital I/O terminal O-NC I-PC O-NC I-PC O-07 I-00 O-06 I-01 O-05 I-02 O-04 I-03 O-03 I-04 O-02 I-05 O-01 I-06 O-00 I-07 O-PC O-PC Interface connector (Connect to a PC’s USB port) Connectors CN1 and CN2 are screw terminal blocks.
Controlling the Product Using USB Using the USB port and CONTROL INPUT terminal simultaneously In remote control through the USB port, the control signal from the CN1 terminal (see the fig- p.54 ure on the previous page) is connected to the product’s CONTROL INPUT terminal. The out- put from the CN1 terminal is an open-collector circuit.
Page 57
Controlling the Product Using USB Starting the diagnosis program On your PC, choose Computer, Properties, and then Device Manager. “CONTEC Devices” appears in the Device Manager window. Right-click CONTEC Devices-DIO DIO-0808LY-USB, and then click Prop- erties. DIO DIO-0808LY-USB “DIO1000” Properties appear. Click Diagnosis on the Common Settings tab.
Page 58
Controlling the Product Using USB Checking the output port operation By controlling specific bits, you can check whether the impedance can be switched properly. Output port Click the bits in the output port to change the internal I/O port output. To switch the imped- ance, set the appropriate bits by referring to the following table.
Page 59
Specifications This chapter lists the electrical and mechanical specifications of the product. Item LIN1020JF LIN3020JF OP01-LIN1020JF JIS C61000-3-2(2011), JETGR0003-1-2.0(2011), JIS C8962(2008), Compliant standards IEC 61000-3-3(2008) Single-phase two-wire Single-phase two- Single-phase three- (Single-phase three- wire, single-phase wire, three-phase wire, three-phase three-wire, three- three-wire, and three- three-wire, and three- phase three-wire, and...
Page 60
Specifications Item LIN1020JF LIN3020JF OP01-LIN1020JF Control output to the Control input from the OP01-LIN1020JF, OP01-LIN1020JF control LIN1020JF, alarm out- alarm input from the Not available put to the LIN1020JF OP01-LIN1020JF I/O terminal Dsub25P Dsub25P Control features When abnormal resistor temperature is detected, the ALARM indica- Protection functions tor lights, a make contact signal is transmitted to turn off (open) all phases at once.
Appendix A Troubleshooting This section introduces troubleshooting measures. Check whether any of the items listed below apply to your case. If following the remedy does not solve your problem, contact your Kikusui agent or distributor. Symptom Inspection Remedy Voltage is not The product’s POWER switch...
Appendix B Connecting the PCR-LE and PCR-LE2 This section describes how to use the output terminal of the PCR-LE and PCR-LE2 AC power supplies. The following description is for connecting the AC power supplies to the LIN-JF. For other details, see the PCR-LE or PCR-LE2 manual. Risk of electric shock.
PCR-LE Output terminal The screw size of the output terminal block varies depending on the model. Terminal block screw size Model Single-phase output PCR1000LE PCR2000LE PCR3000LE PCR4000LE PCR6000LE PCR9000LE Single-phase two-wire output Pull out the OUTPUT Terminal block from the bottom of the AC power supply’s rear panel.
Connecting the PCR-LE and PCR-LE2 Connect the AC power supply’s OUTPUT Terminal to the LIN-JF input terminal. The following figures show a connection example. OUTPUT terminal block G N L LIN1020JF input terminal Sensing The sensing functions that are equipped in the PCR-LE and PCR-LE2 series can be used to reduce the effects of output terminal wiring impedance.
PCR-LE2 This section describes the PCR6000LE2 and PCR9000LE2. For details on the PCR27000LE2, see the PCR-LE2 series AC power supply setup guide or user’s manual. Output terminal The screw size of the output terminal block varies depending on the model. Terminal block screw size Model...
Page 67
Connecting the PCR-LE and PCR-LE2 M4 x 2 Stopper Connect the AC power supply’s OUTPUT Terminal to the LIN-JF input terminal. The connection to the AC power supply OUTPUT terminal is shown in a figure on the next page. Single-phase two-wire output Single-phase three-wire, three-phase three-wire, and three-phase four-wire output Pull out the OUTPUT Terminal block from the bottom of the AC power...
Connecting the PCR-LE and PCR-LE2 Single-phase Three-phase three-wire output output Sensing The sensing functions that are equipped in the PCR-LE and PCR-LE2 series can be used to reduce the effects of output terminal wiring impedance. This simplifies the wiring when they are incorporated in the test system.
Appendix C KHA3000 Input Terminal This section describes how to use the KHA3000 input terminal. One phase (input channel) is described. For details on each phase, see the KHA3000 operation manual. Voltage input terminal Use input terminal V and input terminal ± to connect to the EUT. We recommend that you use UL1015 wires or equivalent with a wire size of AWG18.
KHA3000 Input Terminal Delta transformation (star-delta transformation) The delta transformation feature is used to convert phase voltage measurements of three- phase four-wire circuits to line voltages. Therefore, even if the actual circuit is wired using a three-phase four-wire system, line voltage measurement of a three-phase three-wire system is possible.
Page 71
Index AC INPUT ..........15 temperature range in which specifications are guaran- AC power supplies that can be used ....... 21 teed ..............60 ALARM indicator ......... 15 test circuit ..............21 base hold angle ............7 USB ..............15 BYPASS ..........15 USB port ............19 caster lock lever ............
Page 72
环境保护使用期限 Environment-friendly Use Period 该标记为适用于在中华人民共和国销售的电子信息产品的环境保护使用 期限。 只要遵守有关该产品的安全及使用注意事项,从制造年月起计算,在该 年度内,就不会对环境污染、人身、财产产生重大的影响。 产品的废弃请遵守有关规定。 产品的制造年月可以在以下网址中确认。 http://www.kikusui.co.jp/pi/ 有毒有害物质或元素名称及含有标示 Name of hazardous materials and symbol of element in the equipment and quantity 有毒有害物质或元素 部件名称 铅 汞 镉 六价铬 多溴联苯 多溴二苯醚 PBDE Cr(VI) 印刷电路板组装品 内部接线 外壳 底盘组装品(含变压器) 辅助设备...
Page 74
In either case, please contact your Kikusui agent or distributor. At that time, inform your agent or distributor of the “Part No.” written on the front cover of this manual.