Cartridge Replacement (10-0186) - Amway eSpring 10-0185-CA Owner's Manual

Table of Contents

Advertisement

Available languages

Available languages

CA R T R ID GE R E PL AC EM EN T
(10-01 8 6)
Refer to the exploded view of the
eSpring
Water Purifier for assistance
®
with part names (See inside front cover).
1. Unplug the Power Adapter from the
wall outlet.
2. Turn off water to Water Purifier.
a) If using the Diverter, turn off the
kitchen faucet and place the Water
Purifier in the sink. Pull the metal
pin on the Diverter to drain water
(Fig. 33A).
b) If using the Auxiliary Faucet, turn off the cold water supply using the shut-off
valve
. Turn on Faucet to drain water and leave open
around the Base of the Water Purifier (Fig. 33B).
3. Remove the Top Shroud
. Remove
the Electronic Module
. Then,
remove the tubing removal tool
(Fig. 34).
4. Draw a line with an ink pen across the
top of each tube where it meets the
rings on the Water Purifier (Fig. 35).
5. Make sure the logo on the removal
tool is facing out and the tool is flat
against the Bracket. Firmly push
the tool against the rings with your
fingers and then pull the tubes out
with the opposite hand while rings are
depressed (Fig. 36).
NOTE: If you do not have the Removal Tool,
remove each tube by pressing evenly with
your fingertips on both sides of the rings
that surround the tubing. Then, pull the
tube out with the opposite hand.
6. Unscrew to remove the Retaining Ring
(Fig. 37).
Fig. 33A
Fig. 33B
. Place towels
Fig. 34
Fig. 35
Fig. 36
Fig. 37
7. Lift the handle on the Bracket. Pull straight
up to remove the attached used Cartridge
and Bracket (Fig. 38).
8. Unscrew Cartridge from Bracket to remove
and dispose of the Cartridge in accordance
with local requirements (Fig. 39).
NOTE: The UV lamp in the Cartridge contains
mercury. Please dispose of according to local,
state or federal laws.
9. Empty water from the Base. Then, inspect
seal and upper interior surface of Base and
remove any dirt (Fig. 40).
NOTE: DO NOT allow vegetable oil, petroleum jelly,
or other lubricants, solvents, ammonia, alcohols,
acids, or strong cleaning solutions to come into
contact with the Water Purifier. They could
cause permanent damage to the Base. Use food
grade silicone (WTI-0895) on o-rings to lubricate
if needed. When cleaning, use a mild liquid
dishwashing detergent and water.
10. Remove the protective plastic wrap from
the new eSpring Cartridge (10-0186).
11. Firmly press Cartridge and Bracket together
. Screw the Cartridge onto the Bracket
until it comes to a STOP
(Fig. 41).
12. Reinsert the Bracket (with the attached
Cartridge) into the base by aligning the
notches of the Bracket with the tabs on the
. With the handle down, firmly
Base
push down on the Bracket until it contacts
the Base
(Fig. 42).
Fig. 38
Fig. 39
Fig. 40
Fig. 41
Fig. 42
9