Federal SSRSP Series Installation & Operation Instructions

Refrigerated sandwich prep case
Table of Contents

Advertisement

Quick Links

E3091-2
11/15/19
REV. D
INSTALLATION & OPERATIONS INSTRUCTIONS
KEEP THIS MANUAL FOR FUTURE REFERENCE
Engineering and technical data are subject to change without notice.
FEDERAL INDUSTRIES
Toll Free 1(800) 356-4206
REFRIGERATED SSRSP
SANDWICH PREP CASE MODELS
215 FEDERAL AVE
WI Phone (608) 424-3331
BELLEVILLE, WI 53508
Fax: (608) 424-3234
- 1 -

Advertisement

Table of Contents
loading

Summary of Contents for Federal SSRSP Series

  • Page 1 REFRIGERATED SSRSP SANDWICH PREP CASE MODELS KEEP THIS MANUAL FOR FUTURE REFERENCE Engineering and technical data are subject to change without notice. FEDERAL INDUSTRIES 215 FEDERAL AVE BELLEVILLE, WI 53508 Toll Free 1(800) 356-4206 WI Phone (608) 424-3331 Fax: (608) 424-3234...
  • Page 2: Table Of Contents

    CONTENTS INTRODUCTION .................................3 WARNING LABELS & SAFETY INSTRUCTIONS ......................4 PRE-INSTALLATION PROCEDURES ..........................5 Inspection for Shipping Damage ..........................5 GENERAL ELECTRICAL & GROUNDING ........................5 Permanent Connected ..............................5 Cord Connected (Option) ............................5 Electrical Information ..............................6 INSTALLATION INSTRUCTIONS ...........................6 Locating the Display Case ............................6 Removing Case from Shipping Skid ........................6 Cleaning ...................................6 REFRIGERATION ................................
  • Page 3: Introduction

    INTRODUCTION Thank you for purchasing a Federal Industries display case. This manual contains important instructions for installing and servicing the Refrigerated Self-Service Merchandisers. A repair parts list and wiring diagram are also included in the manual. Read all documents carefully before installing or servicing your case.
  • Page 4: Warning Labels & Safety Instructions

    The warning and safety labels shown throughout this manual are placed on your Federal Industries case at the factory. Follow all warning label instructions. If any warning or safety labels become lost or damaged, call our customer service department at 1(800) 356-4206 for replacements.
  • Page 5: Pre-Installation Procedures

    PRE-INSTALLATION PROCEDURES Inspection for Shipping Damage You are responsible for filing all freight claims with the delivering truck line. Inspect all cartons and crates for damage as soon as they arrive. If damage is noted to shipping crates, cartons, or if a shortage is found, note this on the bill of lading (all copies) prior to signing.
  • Page 6: Electrical Information

    Electrical Information PERMANENTLY CONNECTED SELF CONTAINED REMOTE MODEL VOLTAGE TOTAL AMPS MAX FUSE SIZE VOLTAGE MAX FUSE SIZE SSRSP5052 230/60/1 120/60/1 SSRSP5952 230/60/1 14.5 120/60/1 SSRSP7752 230/60/1 14.5 120/60/1 CORD CONNECTED OPTIONAL SELF CONTAINED MODEL VOLTAGE TOTAL AMPS CORD STYLE 230/60/1 15AMP NEMA 6-15 SSRSP5052...
  • Page 7: Refrigeration

    REFRIGERATION Self Contained Models BEFORE 12/1/19 SELF CONTAINED WITH ELECTRONIC CONTROL SSRSP5052 SSRSP5952 SSRSP7752 Refrigeration R404 Charge 32 OZ 34 OZ 36 OZ (E3091-2 EXCEL) AFTER 12/1/19 The self-contained models are shipped from the factory with a completely operational 404A refrigeration system (before 12/1/19) or 449A refrigeration (after 12/1/19) and require no modifications or adjustments upon installation.
  • Page 8: Remote Models

    Remote Models The remote models are designed to use 449 refrigerant and are shipped from the factory with the evaporator coil, expansion valve, sight glass and refrigerant solenoid valve. A thermostat senses evaporator temperature and opens and closes the refrigerant solenoid valve. The solenoid valve closes and shuts off the refrigeration flow to the unit and initiates a pump down cycle.
  • Page 9: Electronic Expansion Valve

    Note: Check your State and Local regulations for approved refrigerants for your install location. Federal Industries is not liable for any alternate refrigerants used. The control is located in the front left corner of evaporator tub under the Display Deck Pan.
  • Page 10: Shelving Installation & Removal

    SHELVING INSTALLATION & REMOVAL Shelf Bracket & Supports Installation SHELF STANDARD RETAINING SCREW REAR SHELF SUPPORT SHELF LIGHT CORD REAR SHELF SUPPORT RETAINER CLIP LIGHT ASSEMBLY SHELF STANDARD SHELF BRACKET SHELF LIGHT CORD LIGHT ASSEMBLY RETAINER CLIP 1. Turn the light switch to the off position. 2.
  • Page 11: Solid Shelf

    RIGHT WRONG 6. If the socket is not being used for a shelf light, the cap must be plugged into the socket. On models with the 5 pin shelf plug, this is necessary for the entire light system to operate. On models with the 3 pin shelf plug, this is necessary to prevent buildup and damage to the receptacle.
  • Page 12: Glass Shelves (Option)

    Glass Shelf Installation (OPTIONAL) PRODUCT STOP GLASS SHELF GLASS SHELF RETAINER CLIP SHELF STANDARD RETAINING SCREW SHELF STANDARD REAR SHELF OPTIONAL BOTTOM SUPPORT SECTION GLASS SHELF PLACE GLASS SHELF RETAINER CLIP OVER REAR SHELF SUPPORT CORD RETAINER CLIP SHELF LIGHT ASSEMBLY OR SHELF SUPPORT SHELF BRACKET CLIP LOCATED IN FAR...
  • Page 13: Rear Doors

    REAR DOORS (OPTION) BOTTOM SECTION REAR DOORS (OPTIONAL) INNER DOOR UPPER TRACK INNER DOOR LOWER TRACK INNER DOOR CATCH SLOT 1. LIFT UP DOOR 2 SWING BOTTOM OUT 1. LIFT UP DOOR OUTER DOOR UPPER TRACK OUTSIDE DOOR SET 2 SWING BOTTOM OUT OUTER DOOR LOWER TRACK INNER DOOR CATCH 1.
  • Page 14: Night Curtain (Option)

    NIGHT CURTAIN OPERATION NIGHT CURTAIN NIGHT CURTAIN NIGHT CURTAIN PINCHED COVER SANDWICH COVER SANDWICH UNDER GLASS (NO SNAP) PREP AREA AND PREP AREA LOWER SERVICE AREA NIGHT CURTAIN NIGHT CURTAIN SNAP LOCATION IN STORED TO FRONT PANEL POSITION The night curtain rolls up and is stored under the sandwich wrap board as shown in first view. The curtain can be used to cover only the upper sandwich prep area when not in use (as shown in second view).
  • Page 15: Security Night Cover (Option)

    SECURITY NIGHT COVER (OPTION) LOCK HANDLE (SHOWN IN LOCK POSITION) SECURITY NIGHT COVER LOCK HANDLE (SHOWN IN LOCK POSITION) GRAB HANDLE GRAB HANDLE LOCK HANDLE CATCH TOP GLASS HANDLE "U" RATAINER CLIP FRONT CLEAR DEFLECTOR "U" RATAINER CLIP ON CENTER (ON SOME MODELS) LOCK HANDLE CATCH "U"...
  • Page 16: Operating Instructions

    OPERATING INSTRUCTIONS NOTICE: This refrigerated display case is designed to operate in a maximum environment of 75°F (23.9°C) and 55% relative humidity. Exceeding these limits will cause poor case performance and excessive sweating. Temperature Control Functions USER CONTROLS OVERVIEW TEMPERATURE CONTROL POWER SWITCH LIGHT SWITCH Power Switch...
  • Page 17: Button And Display Overview

    Button and Display overview ALARM INDICATOR COMPRESSOR RUN POWER TO CONTROL ON/OFF INDICATOR AND SET POINT UP ADJUST SET POINT ADJUST MODE DEFROST MODE INDICATOR MANUAL DEFROST AND DIGITAL DISPLAY SET POINT DOWN ADJUST Button Overview Press and hold this button for three seconds to turn system on (if off) or off (if on). Also used to adjust set point when in set point adjust mode Press to enter set point adjust mode, confirm set point changes, and mute alarms.
  • Page 18: Entering Manual Defrost Mode

    Entering Manual Defrost Mode button approx. three seconds. The control will read “dEF” while the In order to initiate a manual, defrost press and hold the button is being held. The defrost is initiated when the defrost mode indicator illuminates on the display. The control display will then return to reading the case temperature.
  • Page 19: Electronic Control Operation

    ELECTRONIC CONTROL OPERATION This unit is equipped with an electronic temperature control. The control parameters are set at the factory and cannot be manually changed in the field. The pre set control parameters are listed on the chart in the Settings Chart below.
  • Page 20: Control Parameters

    CONTROL PARAMETERS Table 2 - Control Parameters Parameter Description Control Setpoint → Compressor Cut out [°F] 34.0 32.6 31.3 30.0 28.8 27.6 26.4 25.2 24.0 Compressor Cut in [°F] 39.0° Compressor Min On Time 10 min Compressor Min Off Time 3 min Compressor Max Run Time 90 min...
  • Page 21: Placing Product In Upper Food Pan Section

    SSRSP5052 = (4) HALF PANS, SSRSP5952 = (5) HALF PANS, SSRSP7752 = (7) HALF PANS - A set of divider bars are supplied with each case. If required, additional adapters can be ordered from Federal Industries. - Do not run case without all food pans and all adapters installed.
  • Page 22: Maintenance

    MAINTENANCE Ceiling LED Replacement (Cases Manufactured after 08/01/18) 1. Turn power switch on rear of case to “off.” 2. Disconnect light cord barrel plug from receptacle in LED by pulling barrel plug straight out. 3. The LED is attached to clips mounted to the ceiling. Disengage the LED from the clips. 4.
  • Page 23: Cleaning Instructions

    CLEANING INSTRUCTIONS Daily Cleaning The case should be cleaned thoroughly, as described in the weekly cleaning section, before it is used for the first time. NOTICE: Avoid splashing or soaking any electrical components with water to prevent electrical damage to the case. NOTICE: Shut off lights and power switches and remove all product from case.
  • Page 24: Weekly Cleaning

    Weekly Cleaning This procedure is recommended on a weekly basis. It may need to be performed more often if necessary to maintain a clean, sanitary case. The case should be cleaned to this procedure before using the first time. NOTICE: Avoid splashing or soaking any electrical components with water to prevent electrical damage to the case.
  • Page 25 1. To allow access to clean upper section interior tilt the upper front glass open. Tilt the front glass up by standing in front of the case and grabbing the handle at the bottom of the glass and lifting the bottom of the glass upward.
  • Page 26: Weekly Exterior Cleaning

    surface can be wiped carefully with a soft, wet cloth or chamois. The cloth or chamois must be kept free of grit by frequently rinsing in clean water. Grease and oil can be removed with kerosene. Do not use window cleaners or kitchen scouring compounds. DO NOT use solvents such as Acetone, Benzene, Carbon Tetrachloride, and Lacquer Thinners.
  • Page 27: Service Information

    Phone: (800) 356-4206 and choose the Warranty Parts Option Email: Parts@Federalind.com Federal Industries has partnered with Parts Town for ALL Non-Warranty Part Identification, Pricing, Lead Times, Orders & Freight Quotes. Please contact Parts Town directly if you need parts: Website: PartsTown.com...
  • Page 28: Special Service Situations

    (HFO) from being released into the atmosphere. If moisture or liquid is observed around or under a Federal Industries case, an immediate investigation should be made by qualified personnel to determine the source of the moisture or liquid.
  • Page 29: Sale & Disposal

    SALE & DISPOSAL Owner Responsibility If you sell or give away your Federal Industries case you must make sure that all safety labels and the Installation-Service Manual are included with it. If you need replacement labels or manuals, Federal Industries will provide them free of charge. Contact the customer service department at Federal Industries at (800) 356-4206.
  • Page 30: Wiring Diagrams

    MAIN WIRING DIAGRAMS SELF CONTAINED SSRSP5052 SSRSP5952, SSRSP7752 (Mfg’d Before 12/15/18) REMOTE SSRSP5052, SSRSP5952, SSRSP7752 (Mfg’d Before 12/15/18) - 30 -...
  • Page 31: Self-Contained (Mfg'd After 12/15/18)

    SELF CONTAINED SSRSP5052 SSRSP5952, SSRSP7752 (Mfg’d After 12/15/18 until 12/1/19) REMOTE SSRSP5052, SSRSP5952, SSRSP7752 (Mfg’d After 12/15/18 until 12/1/19) - 31 -...
  • Page 32: Self-Contained (Mfg'd After 1/20/20)

    SELF CONTAINED SSRSP5052 SSRSP5952, SSRSP7752 (Mfg’d After 1/20/20) DEFROST PROBE NOTE PROBE CAREL SSRSP 50,59,77, CORD & PLUG WIRING CONTROL SEL- CONTAINED 230/1/60 TEMP PROBE POWER 91-21035 1/21/20 SWITCH ALTERNATE CONTROL (RANCO) HI/LO PRESS SW SEE CAREL WIRING CONDENSATE PUMP OR EVAPORATOR RELAY OPTIONAL...
  • Page 33: Replacement Parts

    REPLACEMENT PARTS (E3091-2 EXCEL) REFRIGERATION SSRSP5052 SSRSP5952 SSRSP7752 Compressor (SC) 30-18052 30-18645 30-18645 Condensing Unit (SC) 30-20512 30-18215 30-18215 Evaporator Coil 33-13357 33-13358 33-13359 TXV (BEFORE 12/1/19) 32-19419 32-19416 EEV (AFTER 12/1/19) 32-21228 Filter Drier 32-12626 Site Glass 32-54010 Evaporator Fan Motor (SC 240V) 41-19070 Evaporator Fan Motor (remote 120V ) 41-17981...
  • Page 34 PANELS & GLASS SSRSP5052 SSRSP5952 SSRSP7752 Front Glass 50-19570-2 50-19570-3 50-19570-4 Front Glass Clamp 81-18196-2 81-18196-3 81-18196-4 Gas Cylinder 81-19639 81-19639 81-11047 Glass End Clear 50-19584 Glass End Reflective Left(Optional) 50-19584-1L Glass End Reflective Right(Optional) 50-19584-1R End Panel Ass'y Left (Black) 68-19585-L End Panel Ass'y Right (Black) 68-19585-R...
  • Page 35 California Residents Only. WARNING This product can expose you to chemicals including chromium which is known to the State of California to cause cancer and birth defects or other reproductive harm. For more information go to www.P65Warnings.ca.gov - 35 -...
  • Page 36 APP’D CHANGE RECORD DATE ECN# REVISED CONTROL & PARTS LIST 5/14/19 ADDED DUAL PRESSURE CONTROL INFO 8/6/19 3506 - 36 -...

This manual is also suitable for:

Ssrsp5952Ssrsp5052Ssrsp7752

Table of Contents