Download Print this page

Frico SWX EX22 Installation And Maintenance Instructions Manual

Atex approved water fan heater for explosive gas atmospheres

Advertisement

Quick Links

SWX EX12, SWX EX22
MONTERINGS- OCH SKÖTSELANVISNING
SE
ATEX godkänd värmefläkt vatten, för explosiv gasatmosfär
VIKTIGT:
INSTRUKSJONER FOR INSTALLASJON OG VEDLIKEHOLD
NO
ATEX-godkjent vannbåren varmevifte for atmosfærer med eksplosiv gass
VIKTIG:
GB INSTALLATION AND MAINTENANCE INSTRUCTIONS
ATEX approved water fan heater for explosive gas atmospheres
IMPORTANT:
DE INSTALLATIONS- UND WARTUNGSANLEITUNG
ATEX-zugelassener Wasserheizlüfter für explosionsgefährdete Bereiche
WICHTIG:
RU ИНСТРУКЦИЯ ПО МОНТАЖУ И ТЕХОБСЛУЖИВАНИЮ
Одобренные отопительные вентиляторные агрегаты с теплоносителем водой ATEX для
взрывоопасных газовых сред.
ВАЖНО!
INSTRUCTIONS D'INSTALLATION ET DE MAINTENANCE
FR
Aérotherme à eau agréé ATEX pour les environnements comportant des gaz explosifs
IMPORTANT :
INSTRUKCJA MONTAŻU I KONSERWACJI
PL
Termowentylator z certyfikatem ATEX do zastosowań w atmosferze zagrożonej wybuchem
WAŻNE:
ISTRUZIONI DI INSTALLAZIONE E MANUTENZIONE
IT
Termoconvettore ad acqua con approvazione ATEX per atmosfere esplosive per la presenza di gas
IMPORTANTE:
INSTALLATIE- EN ONDERHOUDSHANDLEIDING
NL
ATEX-goedgekeurde luchtverhitter voor wateraansluiting, geschikt voor omgevingen met explosieve gassen
BELANGRIJK:
INSTRUCCIONES DE INSTALACIÓN Y MANTENIMIENTO
ES
Calefactor con ventilador de agua con certificación ATEX para atmósferas de gas explosivas
IMPORTANTE:
ASENNUS- JA HUOLTO-OHJEET
FI
ATEX-hyväksytty vesikiertoinen lämpöpuhallin kaasuräjähdysherkkiin tiloihin
TÄRKEÄÄ:
Läs denna anvisning innan produkten monteras och tas i drift.
Spara denna anvisning för framtida bruk................................................................2
Les disse instruksjonene før du installerer og bruker produktet.
Oppbevar disse instruksjonene for fremtidig bruk..................................................7
Read these instructions before installing and using the product.
Save these instructions for future reference!..........................................................12
Diese Anleitung vor Installation und Verwendung des Produkts lesen.
Diese Anleitung für zukünftige Referenzzwecke aufbewahen.............................17
Перед монтажом и использованием изделия прочтите данную инструкцию.
Сохраните инструкцию для пользования ею в будущем!.............................22
Veuillez lire ces instructions avant l'installation et l'utilisation du produit.
Conservez ces instructions pour toute référence future !.....................................28
Przed montażem i rozpoczęciem użytkowania produktu należy przeczytać
niniejszą instrukcję.
Zachować instrukcję do wykorzystania w przyszłości!.........................................34
Leggere le presenti istruzioni prima di installare e utilizzare il prodotto.
Conservare le istruzioni per futura consultazione!.................................................39
Lees deze handleiding voorafgaand aan de installatie en het gebruik van het product.
Bewaar deze handleiding voor toekomstig gebruik!....................................................44
Lea estas instrucciones antes de instalar y utilizar el producto.
¡Guarde estas instrucciones para futura consulta!................................................49
Lue nämä ohjeet ennen tuotteen asentamista ja käyttämistä.
Säilytä ohjeet myöhempää tarvetta varten!............................................................54
Art.nr: 173123-03

Advertisement

loading

Summary of Contents for Frico SWX EX22

  • Page 1 SWX EX12, SWX EX22 MONTERINGS- OCH SKÖTSELANVISNING ATEX godkänd värmefläkt vatten, för explosiv gasatmosfär VIKTIGT: Läs denna anvisning innan produkten monteras och tas i drift. Spara denna anvisning för framtida bruk..............2 INSTRUKSJONER FOR INSTALLASJON OG VEDLIKEHOLD ATEX-godkjent vannbåren varmevifte for atmosfærer med eksplosiv gass VIKTIG: Les disse instruksjonene før du installerer og bruker produktet.
  • Page 2 SWX EX has been developed specifically for heating the air in environments with occasional danger of explosion (Zone 1 and Zone 2). The fan heater is available in two sizes: SWX EX12 and SWX EX22. Uses hot water as the energy medium.
  • Page 3 SWX EX12, SWX EX22 Fitting of the wall bracket 1. Remove the eight screws indicated by the arrows in photo 1. 2. Install the brackets with the cable attachment holes toward the fan motor connection cable, as shown in photo 2.
  • Page 4 6. Connect the water supply pipe to the lower pipe on the heater and connect the outlet pipe to the upper pipe, as shown by the arrows in photo 6. The connection diameter is 22 mm on SWX EX12 and 28 mm on SWX EX22.
  • Page 5 SWX EX12, SWX EX22 Electrical connection of the fan motor 1. All installation work must be performed by a qualified electrician. 2. The fan heater is constructed for 400 VAC, 3 phase. 3. Electrical connection to the mains requires fixed wiring. A multi-pole breaker with a minimum 3 mm contact gap must be installed in the fixed installation, using Ex approved components in the risk area.
  • Page 6: Cleaning & Maintenance

    SWX EX12, SWX EX22 Cleaning/maintenance 1. Disconnect the power to the fan motor and follow any applicable regulations concerning work in explosive gas environments. 2. The fan heater has a quick release inspection/cleaning plate and a lock nut and lock washer (arrow) for equipotential bonding, see photo 13.
  • Page 7: Technical Data

    SWX EX12, SWX EX22 Appendix A Technical data Type SWX EX12 SWX EX22 Power supply 3~230/400V 3~230/400V Current consumption, 0.43 / 0.25 0.88 / 0.51 Air volume m³/h 2250 4150 Sound level Throw length Connecting pipe Ø22 Ø28 Max. working temp. water °C...
  • Page 8 SWX EX12, SWX EX22 Bilaga B / Tillegg B / Appendix B / Anhang B / Приложение B / Annexe B / Załącznik B / Appendice B / Bijlage B / Anexo B / Liite B SWX EX-AWVS SWX EX12...
  • Page 9 SWX EX12, SWX EX22 Bilaga C / Tillegg C / Appendix C / Anhang C / Приложение C / Annexe C /...
  • Page 10 SWX EX12, SWX EX22 Załącznik C / Appendice C / Bijlage C / Anexo C / Liite C...
  • Page 11: Declaration Of Conformity

    Declaration of Conformity Frico AB Box 102 S-433 22 Partille, Sweden under own responsibility hereby declare that the following product(s) Hot water fan heater for hazardous areas Type of equipment Frico Brand name/trade mark Type designation/models SWX EX 12, SWX EX 22...
  • Page 12: Eu-Type Examination Certificate

    Presafe 15 ATEX 7676X Issue 0 Product: Fan Heater Assembly SWX Ex 12 and SWX Ex 22. Manufacturer: FRICO AB Address: Industrivägen 41, 43361 Sävedalen Sweden. This product and any acceptable variation thereto is specified in the schedule to this certificate and the documents therein referred to.
  • Page 13 22 mm on SWX Ex12 and 28 mm on SWX Ex22. The fan heater are mounted with pipes facing left to right, when the fan heaters is mounted with pipes facing right then the air deflector must be turned for the air to deflect downwards.
  • Page 14 [19] Drawings and documents Number Title Rev. Date 59031 Frico SWX Ex 12/ SW Ex 22 (Type table location and 2017-01-18 warning lable location 173123 Installation and maintenance instrcutions Refer Confidential report D0002321 for the complete descriptive list of technical drawings.
  • Page 15 SWX EX12, SWX EX22...
  • Page 16 SWX EX12, SWX EX22 Main office Frico AB Tel: +46 31 336 86 00 Box 102 Fax: +46 31 26 28 25 SE-433 22 Partille mailbox@frico.se Sweden www.frico.se For latest updated information and information about your local contact: www.frico.se...

This manual is also suitable for:

Swx ex12