MAINTENANCE
Before performing any maintenance, disconnect the appliance from the mains.
Regular maintenance is required for the stove to function correctly.
Any problems resulting from lack of maintenance will immediately void the warranty.

DAILY MAINTENANCE

Operations must be performed when the stove is off, cold and unplugged from the power supply
• Cleaning must be carried out with a vacuum cleaner. (see optional extras page 41).
• Open the door, extract the fire box (1 - fig. A) and tip the residue into the ash drawer (2 - fig. B).
• DO NOT EMPTY THE RESIDUE OUT INTO THE PELLET HOPPER.
• Pull the ash drawer (2 - fig. b) out and empty it into a non flammable container (the ash may still have some parts that are still
hot and/or embers).
• Vacuum out the inside of the fire box, fire grate, and space around the fire box, into which the ash falls.
• Remove the fire box (1 - fig. A) and remove any encrustation using the brush provided, clearing any clogging in the holes.
• Vacuum the fire box, clean the contact edges between the fire box and its seating.
• Clean the glass, if necessary (when cold).
Never vacuum hot ash, it can make the vacuum cleaner breakdown and puts the household rooms at risk of fire.
1
2
fig. B
fig. A

WEEKLY MAINTENANCE

• Remove the ceiling (5 - fig. C) and tip the residue into the ash drawer (2 - fig. B). Removal of the ceiling is possible only after
having removed the baffle (3 - fig. C) by removing the 3 screws located under this baffle (4 - fig. C).
The ceiling is a component subject to wear, Edilkamin does not accept responsibility for it, more so if any breaks are due to ex-
tracting or putting it back in its seating.
• Empty the pellet tank and vacuum the bottom.