Wiper/Washer; Audio; Pixel Counter; Pelco Aux Map - Bosch MIC IP fusion 9000i Operation Manual

Hide thumbs Also See for MIC IP fusion 9000i:
Table of Contents

Advertisement

36
en | Camera
5.14

Wiper/Washer

Wiper
Controls the wiper of the MIC cameras. Options are:
Wiper/washer
Click Start to start the wiper/washer. Click Stop to stop the wiper/washer.
5.15

Audio

Audio
You can set the gain of the audio signals to suit your specific requirements. The live video
image is shown in the window to help you check the audio source. Your changes are effective
immediately.
If you connect via Web browser, you must activate the audio transmission on the 'Live'
functions page. For other connections, the transmission depends on the audio settings of the
respective system.
The audio signals are sent in a separate data stream parallel to the video data, and so increase
the network load. The audio data is encoded according to the selected format and requires
additional bandwidth. If you do not want any audio data to be transmitted, select Off.
Input volume
Set the input volume using the slide. Values range from 0 to 119.
Line Out
Set the line output gain using the slider. Values range from 0 to 115.
Recording format
Select a format for audio recording. The default value is AAC 48 kbps. You can select AAC 80
kbps, G.711 or L16 depending on the required audio quality or sampling rate.
AAC audio technology is licensed by Fraunhofer IIS.
(http://www.iis.fraunhofer.de/amm/)
5.16

Pixel Counter

The number of horizontal and vertical pixels covered by the highlighted area is displayed
below the picture. With these values you can check whether the requirements for specific
functions, for example, identification tasks, are fulfilled.
1.
2.
3.
5.17

Pelco AUX map

Pelco controller keyboards (that support Pelco protocols D and P) support 8 different
auxiliaries (AUX On/OFF commands), but do not define what function each AUX should
perform.
2019-11 | 1.2 |
Off: Turns off the wiper.
On: Wiper wipes continuously until deactivated manually, or until it has been on for five
minutes (after which the camera will stop the wiper automatically).
Intermittent: Wipes twice, then stops. Every 15 seconds, this cycle repeats until users
select another option in this field.
One shot: Wipes five times, then turns off.
Click Freeze to freeze the camera image if the object that you want to measure is moving.
To reposition a zone, place the cursor over the zone, hold down the mouse button and
drag into position.
To change the shape of a zone, place the cursor over the edge of the zone, hold down the
mouse button and drag the edge of the zone to the required position.