9
x
Technical data
Pressurised system - P
Energy Labelling Regulation: (EU) 812/2013 / Ecodesign Regulation: (EU) 814/2013
Energy efficiency class
Standing loss
Hot water storage tank volume
Empty weight
Total filled weight
Dimensions (L x W x H)
Tilt dimension
Maximum permissible storage water temperature
Heat consumption at stand-by and at 60 °C
Water capacity heat exchanger
Maximum operating pressure
Domestic water heat exchanger surface
Water capacity heat exchanger
Heat exchanger surface area
Water capacity heat exchanger
Heat exchanger surface area
Water capacity heat exchanger
Heat exchanger surface area
Water capacity heat exchanger
Heat exchanger surface area
Output characteristic N
in accordance with
L
1)
DIN 4708
Continuous output Q
according to DIN 4708
D
Maximum draw-off rate for the duration of 10 min
on recharging at 35 kW 
(T
= 10 °C / T
= 40 °C / T
KW
WW
Hot water quantity without reheating with up to
15 l/min draw-off rate (T
KW
40 °C/T
= 60 °C)
SP
Hot water volume with post-heating at 15 l/min
draw-off rate (post-charge output 20 kW) 
(T
=10 °C / T
=40 °C / T
KW
WW
Short-term water quantity in 10 min
Cold and hot water
Heating feed and return flow
Solar connections
Tab. 9-3 Basic data EKHWC - pressurised system
1)
With post-charging at 35 kW, 80 °C flow temperature, 65 °C storage tank temperature, 45 °C hot water temperature; 10 °C cold water temperature.
Installation and operating instructions
28
Unit
W
litres
kg
kg
cm
cm
°C
kWh/24 h
Drinking water heat exchanger (stainless steel 1.4404)
litres
bar
2
m
1. Storage tank charging heat exchanger (stainless steel 1.4404)
litres
2
m
2. Storage tank charging heat exchanger (stainless steel 1.4404)
litres
2
m
Pressurised solar heat exchanger (stainless steel 1.4404)
litres
2
m
Solar heating backup (stainless steel 1.4404)
litres
2
m
Heat technics power data
kW
l/min
=60 °C)
SP
= 10 °C/T
=
litres
WW
litres
=60 °C)
SP
litres
Pipe connections
inches
inches
inches
EKHWCH300PB
EKHWCH500PB
64
294
basic data
53
357
59.5 x 61.5 x 164.6
163
1.3
19.0
3.9
9.4
1.9
4.2
0.8
2.2
27
21
200
400
210
EKHWCB500PB
B
72
477
80
593
79 x 79 x 165.8
167
85
1.4
24.5
6
5.0
10.5
2.1
12.5
1.7
3.2
0.4
2.3
35
22
230
230 / 405
500
500 / 858
220
1" AG
1" AG
3/4" IG / 1" AG
Daikin EKHWP/EKHWC/EKHWD
Daikin High-efficiency hot water storage tank
008.1618744 – 03/2017
86
599
11.3
2.3
2.5
45
24
2)
2)
240

Hide quick links: