EKHWP / EKHWC hot water storage tank with solar
system
● Installing a KFE filling connection (accessory KFE BA):
a) With
solar system: on the connection bracket of the
regulation and pump unit (EKSRPS3).
b) With
solar system: on the filling and draining
connection of the Daikin EKHWP / EKHWC.
● Connect the filling hose with backflush prevention (1/2") to
the previously installed KFE filling connection.
● Only with
solar system:
Adjust the valve insert on the connecting angle so that the
path to the filling hose is opened (fig. 4-5).
● Open the KFE cock on the KFE filling connection and the
cold water inlet and fill the storage tank for the Daikin
EKHWP/EKHWC until water comes out of the safety
overflow (fig. 4-5, item 5).
Fig. 4-5
Filling the buffer storage tank - with KFE filling connection
Daikin EKHWP/EKHWC/EKHWD