the device if the data collection period is set to 24 hours, at 00.00 and at 12.00, if the period is
12 hours and so on. All readings are stored in the device memory until the next communication
session. The data transfer period can be adjusted from 1 to 24 hours. Data transfer is carried out
by a random time at the selected period. At the next communication session, the device starts
sending accumulated packets with readings, from the earliest to the latest.
With the "Confirmed uplinks" option turned on, the device will send the next packet only
after receiving a confirmation of the delivery of the previous one. If such confirmation has not
received after the fulfilled in the settings uplink number of transmission, device completes the
communication session until the next one according to the schedule. In this case, the device
continues to collect data according to the data collection period and store it in memory. Non-
transmitted packets remain in the device memory until the next communication session.
With the "Confirmed uplinks" option turned off, the device just sends all accumulated
packets to the network in order from the earliest to the latest. There are no checks of package
delivery in this mode. There are no non-transmitted messages in the device memory.