11.1 CONNECTING THE ROOM THERMOSTAT
access the terminal block M1
remove the jumper from the ends of contacts 1-2
11.2 ACCESSORIES NOT INCLUDED IN THE SUPPLY
11.2.1 EXTERNAL SENSOR
SETTING THE "Kt" CLIMATE CURVE
When the external sensor is connected to the boiler, the
according to the set Kt
pressing
as indicated in the chart in annex SECTION
E for selecting the most appropriate one (00 to 90).
KEY TO CHART - "SECTION" E
11.2.2 CONNECTING TO A ZONE SYSTEM
Z
Zone (1..n)
EV
Zone electrovalve
R
RT
Room thermostat
KEY TO ELECTRICAL CONNECTIONS (see diagram in annex "SECTION" F at the end of this manual).
ambient thermostats can be used to control the other zones.
SYSTEM CONNECTIONS
Connect the Ambient Thermostat contact of the other zones to terminals 1-2 of terminal block M1 (CONNECTING THE
AMBIENT THERMOSTAT section).
Check that parameter P04=02. Set parameter P10 (SETTING PARAMETERS section).
4-5)
Outside temp
33
7219624.01 (1-04/15)