Baxi Duo-tec Combi HE a Range series User Operating Instructions Manual

Baxi Duo-tec Combi HE a Range series User Operating Instructions Manual

Gas fired wall mounted condensing combination boiler

Advertisement

User's Operating Instructions &
Important Warranty Information
Duo-tec Combi HE
Range
A
Gas Fired Wall Mounted Condensing
Combination Boiler
Please keep these instructions in a safe place.
If you move house, please hand them over to the next occupier.
© Baxi Heating UK Ltd 2012

Advertisement

Table of Contents
loading

Summary of Contents for Baxi Duo-tec Combi HE a Range series

  • Page 1 Important Warranty Information Duo-tec Combi HE Range Gas Fired Wall Mounted Condensing Combination Boiler Please keep these instructions in a safe place. If you move house, please hand them over to the next occupier. © Baxi Heating UK Ltd 2012...
  • Page 2: Table Of Contents

    Benchmark is managed and promoted by the Heating and Hotwater Industry Council. For more information visit www.centralheating.co.uk © Baxi Heating UK Ltd 2012 All rights reserved. No part of this publication may be reproduced or transmitted in any form or by any means, or stored in any...
  • Page 3: Quick Reference Guide

    Central Heating System Pressure - The normal operating water pressure is between 1 and 2.0 bar. If the pressure exceeds 3 bar the safety pressure valve will operate and a fault is indicated. Contact your Installer. © Baxi Heating UK Ltd 2012...
  • Page 4: Troubleshooting

    ? If the reading falls below 1 bar repressurise the system as Turn the ON/OFF/Reset described in section 3.1. Selector Switch to Reset. If boiler does not Reset Error Code E119 showing low pressure. © Baxi Heating UK Ltd 2012...
  • Page 5 INSTALLER OR SERVICE ENGINEER. If you don’t know what you need to do to get the boiler to light, or need help with the system and controls, contact your installer as soon as possible. © Baxi Heating UK Ltd 2012...
  • Page 6: Repressurising System

    Requires 8. Disconnect the copper pipe from the taps (a small Repressurising amount of water may be present) and remove it. Keep the pipe in a safe place for future use. © Baxi Heating UK Ltd 2012...
  • Page 7: Clearances

    11. It is important that the condensate drain system is Purposes not blocked, modified or damaged in any way as this would affect the operation of your boiler. Your installer should have insulated any exposed pipework. 5mm Min Fig. 4 In Operation © Baxi Heating UK Ltd 2012...
  • Page 8: Care Of The Boiler

    5 E133 Interruption Of Gas Supply or Flame Failure seconds. If the boiler does not relight, or the code is displayed Fan or Fan Wiring Fault E160 regularly contact your installer or service engineer. © Baxi Heating UK Ltd 2012...
  • Page 9: Legislation

    3. This product should be serviced regularly to optimise its safety, efficiency and performance. The service engineer should complete the relevant Service Record on the Benchmark Checklist after each service. 4. The Benchmark Checklist may be required in the event of any warranty. © Baxi Heating UK Ltd 2012...
  • Page 10: Notes

    7.0 Notes © Baxi Heating UK Ltd 2012...
  • Page 11: Emergency

    (Fig. 6). 3. Call your Installer or Service Engineer as soon as possible. Fig. 6 Heating Flow, Heating Return and Mains Water Inlet Isolating Valves © Baxi Heating UK Ltd 2012...
  • Page 12: Warranty & Service

    Standard Warranty Terms & Conditions To activate your second year free warranty you must register your boiler with heateam the service division of Baxi Heating UK Ltd either by completing and returning the registration card or calling our telephone registration line on 0800 013 7989.

Table of Contents