Belden HIRSCHMANN IT Dragonfly Series User's Manual & Installation Manual
Belden HIRSCHMANN IT Dragonfly Series User's Manual & Installation Manual

Belden HIRSCHMANN IT Dragonfly Series User's Manual & Installation Manual

Enterprise wireless access point

Advertisement

Quick Links

User Manual
Installation
Dragonfly Enterprise Wireless Access Point
DAP645
DAP646
DAP647
Installation DAP645/646/647
Release 01 04/2022
https://hirschmann-it-support.belden.com
Technical support

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the HIRSCHMANN IT Dragonfly Series and is the answer not in the manual?

Questions and answers

Subscribe to Our Youtube Channel

Summary of Contents for Belden HIRSCHMANN IT Dragonfly Series

  • Page 1 User Manual Installation Dragonfly Enterprise Wireless Access Point DAP645 DAP646 DAP647 Installation DAP645/646/647 Technical support Release 01 04/2022 https://hirschmann-it-support.belden.com...
  • Page 2 The performance characteristics described herein shall be binding only upon the express consent of the parties at the time of signing the contract. This paper is produced by Belden within its capacity. Belden reserves the right to change the contents of this manual without prior notice. Belden does not guarantee the correctness or accuracy of the information in this manual.
  • Page 3: Table Of Contents

    Contents Important information ............... 5 Safety instructions ................6 Outdoor installation ................7 Notes for countries with the following country codes: ....... 10 Supplier's Declaration of Conformity ..........12 U.S. Contact Information ..............12 About this manual ................13 Key …………………………………………………………………………………….13 Description ................
  • Page 4 Disassembly ................55 Technical data ................ 56 General technical data ..............56 Dimension drawings ................. 57 WLAN module specifications ............58 EMC ....................60 Immunity ..........Error! Bookmark not defined. Network range.................. 61 Power consumption/power output ............ 61 Scope of delivery ..............62 Order number ................
  • Page 5: Important Information

    Important information Note: Read these instructions carefully and familiarize yourself with the device before trying to install, operate, or maintain it. The following notes may appear throughout this documentation or on the device. These notes warn of potential hazards or call attention to information that clarifies or simplifies a procedure.
  • Page 6: Safety Instructions

    Safety instructions WARNING UNCONTROLLED MACHINE ACTIONS To avoid uncontrolled machine actions caused by data loss, configure all data transmission devices individually. Before you start any machine, which is controlled via data transmission, ensure to complete the configuration of all data transmission devices. Failure to follow this instruction can result in death, serious injury, or equipment damage.
  • Page 7: Outdoor Installation

    Outdoor installation Applies to device with supply voltage (PoE): ▶ You connect the device supply via Power over Ethernet (PoE), the circuit classification ID 1 according to IEC/EN 62368-1, Table 14 applies (max. transient voltage 1500 V, 10/700 µs). ▶ The device has been approved for outdoor installation in a pollution degree 2 environment and according to outdoor enclosure.
  • Page 8 Lightning protection and surge protection Applies exclusively to devices and antennas installed outdoors: ▶ The installation of the device must be carried out by a lightning protection professional in accordance with valid standards (such as IEC 62305 / DIN EN 62305 (VDE 0185-305), and in accordance with the lightning protection procedures recognized and proven for the application and the environment.
  • Page 9 Stuttgarter Str. 45-51 72654 Neckartenzlingen Germany You find the EU conformity declaration as PDF file for downloading on the Internet at: https://catalog.belden.com The product can be used in residential areas (residential, commercial and light-industrial environments). Installation DAP645/646/647 Release 01 04/2022...
  • Page 10: Notes For Countries With The Following Country Codes

    Notes for countries with the following country codes: AT BE BG CH CY CZ DE DK EE FR HR HU EL ES LT LU LV MT NL NO PL PT RO RS SE SK TR ▶ The RED compliance requires compliant operation of the device in the 5 GHz band channels.
  • Page 11 S.I. 2017 No. 1206 Radio Equipment Regulations The UKCA conformity declaration will be available to the relevant authorities at the following address: Belden UK Ltd. 1 The Technology Centre, Station Road Framlingham, IP13 9EZ, United Kingdom You find the UKCA conformity declaration as PDF file for downloading on the Internet at: https://www.doc.hirschmann.com/certificates.html...
  • Page 12: Supplier's Declaration Of Conformity

    47 CFR § 2.1077 Compliance Information DAP645 DAP646 DAP647 U.S. Contact Information Belden – St. Louis 1 N. Brentwood Blvd. 15th Floor St. Louis, Missouri 63105, United States Phone: 314.854.8000 This product has been tested and found to comply with the limits for a Class A digital device pursuant to Part 15 of the FCC Rules.
  • Page 13: About This Manual

    Documentation mentioned in the “User Manual Installation” that is not supplied with your device as a printout can be found as PDF files for downloading on the Internet at: https://catalog.belden.com The symbols used in this manual have the following meanings: ▶...
  • Page 14: Description

    Description General device description Hirschmann IT Dragonfly outdoor series is enterprise level Wi-Fi 6(802.11ax) certified access point including DAP645/646/647. There are convenient options for managing the device. Manage your devices via: ▶ Web browser ▶ ▶ Telnet The device works without a fan. The device complies with the degrees of protection IP67.
  • Page 15: Device View Dap645/ Dap646

    Device view DAP645/ DAP646 Figure 1: Device view DAP645/ DAP646 Factory reset. Press reset button for 5s, AP LEDs Reset will quickly flash for 3s, then AP will restart and restore factory configurations SFP module need to be purchased additionally Don’t open or remove Protective vents The grounding must be completed before powering...
  • Page 16: Device View Dap647

    Device view DAP647 Figure 2: Device view DAP647 Factory reset. Press reset button for 5s, AP LEDs Reset will quickly flash for 3s, then AP will restart and restore factory configurations SFP module need to be purchased additionally Don’t open or remove Protective vents The grounding must be completed before powering Grounding point...
  • Page 17: Power Supply

    Power supply You have the following options to supply your device with voltage: 1.5.1 Supply voltage with PoE Power supply via RJ45 socket for PoE port Your device support PD (powered device) and PSE (power sourcing equipment). Connect the device via a twisted pair cable on the PD port as power supply input, and on the PSE port as power supply output.
  • Page 18: Display Elements

    ▶ Autonegotiation ▶ Autopolarity ▶ 10 Mbit/s half-duplex mode, 10 Mbit/s full duplex mode ▶ 100 Mbit/s half-duplex mode, 100 Mbit/s full duplex mode ▶ 1000 Mbit/s full duplex ▶ 2500 Mbit/s full duplex ▶ Power over Ethernet The socket housing is electrically connected with the device housing. Delivery state: Autonegotiation activated The PoE power is supplied via the wire pairs transmitting the signal (phantom voltage).
  • Page 19 Lights Activity Meaning PSE enabled SFP linkup Eth1 Ethernet1 linkup Eth0 Ethernet0 linkup 5GHz SSID created and running 2.4G 2.4GHz SSID created and running Bootloader-OS loading and system running Flashing Bootloader-OS upgrading Installation DAP645/646/647 Release 01 04/2022...
  • Page 20: Management Interfaces

    Management interfaces 1.8.1 Reset button The device has a reset button. The reset button is located behind a screwable IP67 protection cap. Press reset button for 5s, LED will quickly flash for 3s, then the device will restart and restore factory configurations Prerequisite: Keep the working area dry and clean when you are carrying out a reset.
  • Page 21: Installation

    Installation WARNING ELECTRIC SHOCK Exclusively install this device in a restricted access location, to which maintenance staff have exclusive access. Install the device in such a way that it is protected against mechanical forces in the area of the power supply. Failure to follow this instruction can result in death, serious injury or damage of the equipment.
  • Page 22: Checking The Package Contents

    Checking the package contents □ According to the device variant, check whether the package contains all items listed in the scope of delivery: “Scope of delivery on page 62 □ Check the individual parts for transport damage. Installing and grounding the device 2.2.1 Installation for DAP645 2.2.1.1 Pre-Installation Checklist Before installing your DAP645, be sure that you have the materials and tools listed...
  • Page 23 □ Tools: ■ ■ Ratchet Crimping Tool for RJ45 Modular Plug ■ ■ Hexagon sockets Ethernet cable tester. ■ ■ Screwdriver Heat shrinkable tube ■ ■ Rotary hammer Heat gun ■ Percussion bit Φ8 ■ Fiber melt machine (Optional) ■ Ratchet Crimping Plier for non-insulated termina Item...
  • Page 24 2.2.1.2.1.1 Materials Preparation Item Description Graphics Mounting bracket(D1) Mounting bracket (D2) Mounting bracket (D3) Spacing tube Screw bolt M8 x 65 Screw bolt M8 x 25 Spring washer Φ8 Screw nut M8 Locknut M8 2.2.1.2.1.2 Assembly Processes Set-1: Insert the Mounting bracket (D2) into Bracket (D3) and align Mounting bolt hole (A) with Mounting bolt hole (B).
  • Page 25 Set-3: Insert the Spacing tube (D4) into bracket (D2), align the hole of the tube (D4) with the Mounting bolt hole (B) of Bracket (D2). Set-4: From the side of Bracket (D3), where Dowel pin (B) stands, put the Screw bolt (D5) through the Mounting bolt hole (A) and stick out at the other side.
  • Page 26 Set-5: To prevent the screw nut from loosening and for better reliability, put a Locknut (D11) on the end of the Screw bolt (D5). Then tighten it up with ratchet wrench. Note: Must use a proper Ratchet wrench to tighten the Screw nut (D10) and the Locknut (D11).
  • Page 27 Set-9: To prevent the screw nut from loosening and for better reliability, put a Locknut (D11) on the end of the Screw bolt (D6). Then tighten it up with ratchet wrench. Note: Must use a proper Ratchet wrench to tighten the Screw nut(D10) and the Locknut(D11) Set -10: Get Mounting kit (E).
  • Page 28 Mounting kit(E) Screw bolt M6 x 12 Spring washer Φ6 2.2.1.2.2.2 Assembly Processes Set -11: Connecting the AP (A) with Mounting kit (E). Set -12: Get Final Assembly (F) 2.2.1.3 Mounting the AP to a Pole or a Wall The AP is for outdoor deployment, it can be mounted to a pole or a wall by using the accessories in the mounting kit package.
  • Page 29 Final Assembly Hose clamp 2.2.1.3.1.2 Mounting Processes Set -13: Threading the Hose clamps (D12) through the square mounting holes in Bracket (D3) separately. Considering your handedness, the direction of the screw head on the hose clamp should be determined before you thread. Set -14: Mounting to a pole.
  • Page 30 2.2.1.3.2 Wall Mounting 2.2.1.3.2.1 Materials Preparation Item Description Graphics Final Assembly Expansion bolt M6x60 2.2.1.3.2.2 Mounting Processes Set -15: Draw four center marks on the wall where is planned to mount the outdoor AP. And then drill four Φ8×45 mm holes on the wall for expansion bolts. Set -16: Insert 4 Expansion bolts (D13) into the holes on the wall separately.
  • Page 31 Set -17: Put the 4 expansion bolts through the 4 mounting holes in Bracket (D3). Then put a flat washer, a spring washer and a screw nut on each expansion bolt in sequence. Finally, tighten the 4 screw nuts with ratchet wrench. 2.2.2 Installation for DAP646/ DAP647 2.2.2.1 Pre-Installation Checklist Before installing your DAP646/DAP647, be sure that you have the materials and...
  • Page 32 Item Description Graphics Mounting bracket(D1) Mounting bracket(D2) Mounting bracket(D3) Spacing tube Screw bolt M8 x 65 Screw bolt M8 x 25 Screw bolt M6 x 12 Spring washer Φ8 Spring washer Φ6 Screw nut M8 Locknut M8 Hose clamp (102-152 mm) Expansion bolt M6x60 2.2.2.2 Using the AP-MNT-OUT Mounting Kits 2.2.2.2.1 Assembling Access Point (A) with Mounting bracket (D1), to get subassembly (E1).
  • Page 33 Mounting bracket (D1) Screw bolt M6 x 12 Spring washer Φ6 2.2.2.2.1.2 Assembly Processes Set-1: Connecting the AP (A) with Mounting bracket (D1). Step-2: Get Subassembly (E1). Note: Must use a proper Ratchet wrench to tighten the Screw bolt (D7). 2.2.2.2.1 Assembling Mounting bracket(D2) with Bracket (D3), to get subassembly (E2).
  • Page 34 2.2.2.2.1.1 Materials Preparation Item Description Graphics Mounting bracket(D2) Mounting bracket(D3) Spacing tube Screw bolt M8 x 65 Spring washer Φ8 Screw nut M8 Locknut M8 2.2.2.2.1.2 Assembly Processes Step-3: Insert the Mounting bracket (D2) into Bracket (D3) and align Mounting bolt hole (A) with Mounting bolt hole (B).
  • Page 35 Set-5: Insert the Spacing tube (D4) into Bracket (D2), align the hole of the Tube (D4) with the Mounting bolt hole (B) of Bracket (D2). Set-6: From the side of Bracket (D3), where Dowel pin (B) stands, put the Screw bolt (D5) through the Mounting bolt hole (A) and stick out at the other side.
  • Page 36 the end of the Screw bolt (D5). Then tighten it up with ratchet wrench. Note: Must use a proper Ratchet wrench to tighten the Screw nut (D10) and the Locknut (D11). Set-8: Get Subassembly (E2) 2.2.2.2.2 Assembling Subassembly (E1) with Subassembly (E2), to get Final-Assembly (F). 2.2.2.2.2.1 Materials Preparation Item...
  • Page 37 Screw nut M8 Locknut M8 2.2.2.2.2.2 Assembly Processes Set-9:Overlap Subassembly (E1) to Subassembly (E2), align the Mounting bolt hole (C) with Mounting bolt hole (D). Set -10: To get a required horizontal angle, adjusting the Dowel pin (C) on Bracket (D2) to match up with the Positioning teeth of Bracket (D1).
  • Page 38 Set -12: To prevent the screw nut from loosening and for better reliability, put a Locknut (D11) on the end of the Screw bolt (D6). Then tighten it up with ratchet wrench. Note: Must use a proper Ratchet wrench to tighten the Screw nut (D10) and the Locknut (D11).
  • Page 39 Hose clamp 2.2.2.3.1.2 Assembly Processes Set -14: Threading the Hose clamps (D12) through the square mounting holes in Bracket (D3) separately. Considering your handedness, the direction of the screw head on the hose clamp should be determined before you thread. Set -15: Mounting to a pole Caution: Use caution to prevent hand injury!
  • Page 40 2.2.2.3.2 Wall Mounting 2.2.2.3.2.1 Materials Preparation Item Description Graphics Final Assembly Expansion bolt M6x60 2.2.2.3.2.2 Mounting Processes Set -16: Draw four center marks on the wall where is planned to mount the outdoor AP. And then drill four Φ8×45 mm holes on the wall for expansion bolts. Set -17: Insert 4 Expansion bolts (D13) into the holes on the wall separately.
  • Page 41 2.2.3 Grounding the device WARNING ELECTRIC SHOCK Ground the device before connecting any other cables. Failure to follow this instruction can result in death, serious injury, or damage of equipment. All devices have a protective ground connection The earthing terminal shall have permanently connected to building earth.
  • Page 42: Installing The Antennas

    □ Crimping the Grounding wire. Peel the cover of one end of the grounding wire and place the bare grounding wire into the O-Terminal and press firmly with the crimping pliers. A heat shrinkable tube is suggested to put on. □...
  • Page 43: Connecting The Power Supply

    On delivery, the antenna connections are sealed with transport protection caps. Perform the following work steps: □ Remove the pre-mounted transport protection caps from the antenna connections. □ Install at least one 2.4G or 5G antenna on the radio module that you would like to use. □...
  • Page 44 Installation DAP645/646/647 Release 01 04/2022...
  • Page 45: Connecting Data Cables

    Connecting data cables Note the following general recommendations for data cable connections in environments with high electrical interference levels: □ Keep the length of the data cables as short as possible. □ When using copper cables, provide a sufficient separation between power supply cables and the data cables.
  • Page 46 2.5.1.2 Crimping the Ethernet cable The following figure shows the process of crimping Ethernet cable. Caution: Do Not peel the cover of the Ethernet cable or attach the RJ45 connector to the cable before sliding the Cable gland (B) over the cable. Failure to use the included Ethernet cable glands can lead to product issues.
  • Page 47 Connect the Seals with Clamping ring (B2+B3) to the Gland body (B4), and then screw the Sealing nut (B1) onto the Gland body (B4) and tighten it firmly. Caution: Do not screw the Sealing nut (B1) onto the Gland body (B4) before connecting the RJ45 connector to the Ethernet port.
  • Page 48 Seals 1 Seals 2 2.5.2.4 Insert the Cable through the Sealing Nut, Clip, Seals, Body And 0-Ring. 2.5.2.5 The insert Seals & Clip. 2.5.2.6 The insert sealing nut the torque force: 10~12Kgf/cm2. Assembly Finished. Installation DAP645/646/647 Release 01 04/2022...
  • Page 49: First Login (Password Change)

    First login (Password change) To help prevent undesired access to the device, it is imperative that you change the default password during initial setup. Perform the following steps: □ By default, DAP will broadcast the WLAN ‘mywifi-xxxx’ (xxxx = the last two bytes of the AP MAC address). You can connect to ‘mywifi-xxxx’...
  • Page 50 □ Confirm your new password. Note: The page below will be displayed to select the country or region. Installation DAP645/646/647 Release 01 04/2022...
  • Page 51: Defining Wlan Basic Settings

    4 Defining WLAN basic settings You have the following options to define the WLAN basic settings: ▶ via the wired local network (LAN) ▶ via the wireless network (WLAN), if the WLAN encryption (for example WPA2) is set accordingly in a device with a wireless interface and in the configuration computer. For more details, please refer to user manual.
  • Page 52: Configuring The Transmit Power

    5 Configuring the transmit power You can modify the transmission power and working channel for the DAP in the RF Configuration Window, shown in below figure, by default, the working channel and transmitting power are automatically managed by Dynamic Radio Management (DRM) technology.
  • Page 53 Key word specification in RF Configuration Window Parameter Specification When enabled, Auto Channel Selection does not change channels for DAPs with connected clients, except for high- Client Aware priority events such as RADAR detected. If "Client Aware" is Disabled, the DAP may change to a more optimal channel, which may temporarily disrupt current client traffic.
  • Page 54: Maintenance And Service

    Check regularly whether there is an updated version of the software that provides you with additional benefits. You find information and software downloads on the Hirschmann IT product pages on the Internet (https://catalog.belden.com/) □ Depending on the degree of pollution in the operating environment, check at regular intervals that ports in the device are not obstructed.
  • Page 55: Disassembly

    7 Disassembly □ Disconnect the data cables. □ Disable the supply voltage. □ Remove the antennas. □ Disconnect the grounding. Installation DAP645/646/647 Release 01 04/2022...
  • Page 56: Technical Data

    8 Technical data 8.1 General technical data Dimensions See “Dimension drawings” on page 42 DAP645/ DAP646/ DAP647 W × H × D DAP645/ DAP646 2.5kg (88.18lb) Weight DAP647 2.7kg (95.24lb) Supply voltage Connection type PoE Input Rated voltage PoE Input: 54 V PoE Input: 600mA/1600mA Rated current maximum tolerances...
  • Page 57: Dimension Drawings

    8.2 Dimension drawings DAP645/DAP646 DAP647 Installation DAP645/646/647 Release 01 04/2022...
  • Page 58: Wlan Module Specifications

    8.3 WLAN module specifications 8.3.1 Radio technology Antenna connection Each WLAN module: 6 × N socket Range Depending on the antenna used, frequency range and data rate ▶ Encryption Static WEP ▶ WPA3 Personal ▶ WPA2 Personal ▶ WPA Personal ▶...
  • Page 59 8.3.3 Receiving sensitivity, transmit power, and data rate of the WLAN module The values shown in the following tables are the maximum values of the WLAN module. The values are in no case to be perceived as a guaranteed property of the overall product.
  • Page 60: Emc

    8.4 EMC EMC interference immunity EN 61000-4-2 Electrostatic discharge EN 60601-1-2 Contact discharge, test level 4 8 KV EN 61131-2 Air discharge, test level 4 15 KV EN 61000-4-3 Electromagnetic field EN 60601-1-2 80 MHz ... 3000 MHz max. 10 V/m EN 60601-1-2 3000 MHz ...
  • Page 61: Network Range

    8.6 Network range 10/100/1000/2500 Mbit/s twisted pair port Length of a twisted pair segment max. 100 m (328 ft) (for Cat5e cable) Network range: 10/100/1000/2500 Mbit/s twisted pair port Product code Length of Optical Mode F/O cable length example BLPc/dispersion MTS-SFP-1G-...
  • Page 62: Scope Of Delivery

    9 Scope of delivery Number Article 1 × Device 1 × Safety instruction 1 × Qualification 2 × Cable gland Order number Device Order number DAP645-RW 942 999-308 DAP646-RW 942 999-312 DAP647-RW 942 999-316 Accessories Designation Order number AP-MNT-OUT 942999338 Outdoor AP mounting kit, Pole/Wall installation, independent packing.
  • Page 63: Underlying Technical Standards

    12 Underlying technical standards Name CAN/CSA 22.2 No. 62368-1 Information Technology Equipment – Safety – Part 1: General Requirements EN 300 328 Electromagnetic compatibility and radio spectrum matters (ERM) - bandwidth transfer systems - data transmission equipment operating in 2.4 GHz ISM band and using spread spectrum modulation technology Broadband radio access networks (BRAN) –...
  • Page 64: A Further Support

    For technical questions, please contact any Hirschmann IT dealer in your area or Hirschmann IT directly You find the addresses of our partners on the Internet at https://catalog.belden.com/ A list of local telephone numbers and email addresses for technical support directly from Hirschmann IT is available at https://catalog.belden.com/...
  • Page 65 Installation DAP645/646/647 Release 01 04/2022...