Open dual-band industrial access-point / client / accessbridge (90 pages)
Summary of Contents for Belden HIRSCHMANN IT DAP847
Page 1
User Manual Installation Dragonfly Industrial Wireless Access Point DAP847 Installation DAP847 Technical support Release 01 12/2023 https://hirschmann-it-support.belden.com...
Page 2
This document was produced by Belden according to the best of the company’s knowledge. Belden reserves the right to change the contents of this document without prior notice. Belden can give no guarantee in respect of the correctness or accuracy of the information in this manual.
Contents Important information..............5 Safety instructions ................ 6 About this manual ................ 14 Key ....................15 1 Description ................16 1.1 General device description ..............16 1.2 Device name and product code ............17 1.3 Device view ..................18 1.4 Power supply ..................19 1.4.1 DC Power supply ................
Page 4
3 First login (Password change) ..........37 3.1 First login on DAP847-XXA ..............37 3.2 First login on DAP847-XXC ..............40 4 Defining WLAN basic settings ..........42 4.1 Defining WLAN basic settings on DAP847-XXA ........42 4.2 Defining WLAN basic settings on DAP847-XXC ........42 5 Configuring the transmit power ..........
Important information Note: Read these instructions carefully, and familiarize yourself with the device before trying to install, operate, or maintain it. The following notes may appear throughout this documentation or on the device. These notes warn of potential hazards or call attention to information that clarifies or simplifies a procedure. Symbol explanation ...
Safety instructions WARNING UNCONTROLLED MACHINE ACTIONS ACTIONS DES MACHINES INCONTRÔLÉES To avoid uncontrolled machine actions caused by data loss, configure all the data transmission devices individually. Pour éviter les actions des machines incontrôlées causées par la perte de données, configurez individuellement tous les dispositifs de transmission de données.
Page 7
Certified usage Use the product only for the application cases described in the Hirschmann IT product information, including this manual. Operate the product only according to the technical specifications. “Technical data” on page Connect to the product only components suitable for the requirements of the specific application case.
Page 8
Installation Applies to device variants featuring supply voltage (24 V DC / 110 V DC) that comply with all of the following requirements: You connect the device to a power supply that complies with the requirements for a safety extra-low voltage (SELV) according to IEC 60950-1 or ES1 according to IEC/EN 62368-1 and with the overvoltage category II (OVC II).
Page 9
National and international safety regulations Verify that the electrical installation meets local or nationally applicable safety regulations. Grounding the device Grounding the device is by means of a separate protective ground connection on the device. Ground the device before connecting any other cables. ...
Page 10
In accordance with the above-named EU directive(s), the EU conformity declaration will be available to the relevant authorities at the following address: Belden Deutschland GmbH Im Gewerbepark 2 58579 Schalksmühle Germany...
Page 11
S.I. 2017 No. 1206 Radio Equipment Regulations The UKCA conformity declaration will be available to the relevant authorities at the following address: Belden UK Ltd. 1 The Technology Centre, Station Road Framlingham, IP13 9EZ, United Kingdom You find the UKCA conformity declaration as PDF file for downloading on the Internet at: https://catalog.belden.com/index.cfm?event=browse&c=Category_815381...
Page 12
FCC note Supplier's Declaration of Conformity 47 CFR § 2.1077 Compliance Information DAP847 U.S. Contact Information Beldon Inc. 1 N. Brentwood Blvd. 15th Floor St. Louis, Missouri 63105, United States Phone: 314.854.8000 This device complies with part 15 of the FCC rules. Operation is subject to the following two conditions: ...
Page 13
RF exposure warning This equipment complies with FCC and CE radiation exposure limits set forth for an uncontrolled environment. This product may not be collocated or operated in conjunction with any other antenna or transmitter. Confirm that this equipment is installed and operated in accordance with the provided instructions.
Documentation mentioned in the “User Manual Installation” that is not supplied with your device as a printout can be found for downloading on the Internet at: https://catalog.belden.com. Installation DAP847 Release 01 12/2023...
The symbols used in this manual have the following meanings: List ▶ Work step □ Subheading ■ Link Cross-reference with link Note: A note emphasizes a significant fact or draws your attention to a dependency. Installation DAP847 Release 01 12/2023...
Description 1.1 General device description We provide industrial grade wireless access solutions for verticals such as rail transit, process automation, discrete automation, and energy, which include access points (APs) and client terminals. Both AP and client adopt the latest Wi Fi 6 (IEEE 802.11ax) technologies.
1.2 Device name and product code The device name corresponds to the product code. The product code is made up of characteristics with defined positions. The characteristic values stand for specific product properties. Product Number Product Code Product Description Dragonfly Outdoor Wi-Fi 6 (802.11ax) Access Point, 9AA 101 001 DAP847-RWAPKT899THH PoE PD only, Extended Temp...
1.3 Device view Figure 1: Device View Supply voltage connection 24V/110V DC, 4-pin, 7/8" socket V. 24 4-pin, “A”-coded M12 socket Ethernet port (PoE) 8-pin, "X"- coded M12 socket for 10/100/1000/2500 Mbit/s twisted pair connections. This port supports POE+. IEEE 802.3at/bt compliant. Air valve Do not open Reset button...
1.4 Power supply The device supports the DC input power supply and the power supply through PoE. 1.4.1 DC Power supply The device supports the DC input power supply. One typical voltage is 24 V DC, and the other typical voltage is 110 V DC. 1.4.2 Power supply through PoE Your device is a PD (Powered Device).
1.5 Ethernet ports You have the option of connecting end devices or other segments to the ports of the device via twisted pair cables. You can find the information on the pin assignments for making patch cables in section Pin assignments on page 1.5.1 10/100/1000/2500 Mbit/s PoE PD port This port is an 8-pin, "X"- coded M12 socket.
N-Abschl-Wdst. 50 Ohm resistor to avoid suffering from signal interference. The "Antenna Guide" document provides an overview of the antennas that can be used as well as the suitable antenna accessories. The manual is available for download on the Internet: https://catalog.belden.com. Installation DAP847 Release 01 12/2023...
1.7 Display elements After the supply voltage is set up, the software starts and initializes the device. Afterwards, the device performs a self-test. During this process, various LEDs light up. 1.7.1 Device state The device is equipped with an LED display that indicates different status with different colors.
1.8 Management interfaces 1.8.1 Reset button Prerequisite: Keep the working area dry and clean before a reset is carried out. The device has a reset button, which is located behind a screwable IP67 protection cap. The tightening torque is 0.5 Nm to 1.0 Nm (4.42 lb-in to 8.85 lb- in).
1.8.2 V.24 interface (external management) This interface is a 4-pin, “A”-coded M12 socket. This interface is serial and enables the local connection of an external management station (VT100 terminal or PC with corresponding terminal emulation). This enables you to set up a connection to the Command Line Interface CLI and to the System Monitor.
Installation WARNING ELECTRIC SHOCK CHOC ÉLECTRIQUE Exclusively install this device in a restricted access location, to which maintenance staff have exclusive access. Install the device in such a way that it is protected against mechanical forces in the area of the power supply. Installez exclusivement ce dispositif dans un emplacement à...
2.1 Checking the package contents According to the device variant, check whether the package contains all items listed in the scope of delivery. “Scope of delivery, order number, and accessories” on page Check the individual parts for transport damage. Installation DAP847 Release 01 12/2023...
2.2 Installing and grounding the device 2.2.1 Installing the device onto or on a flat surface You have the option of attaching the device with suitable hardware to a vertical flat surface. Proceed as follows: Prepare the assembly at the installation site. See “Dimension drawings”...
2.3 Installing the antennas WARNING ELECTRIC SHOCK ÉLECTROCUTION Mount the antennas outdoors only with the surge protection device BAT ANT- Protector m-f. Montez les antennes uniquement à l’extérieur avec le dispositif de protection contre les surtensions BAT ANT-Protector m-f. See “Scope of delivery, order number, and accessories” on page 57. Failure to follow this instruction can result in death, serious injury, or damage of equipment.
Page 30
The device has connections for external antennas. These connectors are N female sockets. On delivery, the antenna connections are sealed with protection caps. When an antenna port is not used, Hirschmann recommends using an N-Abschl-Wdst. 50 Ohm resistor to avoid suffering from signal interference. BAT-ANT-Protector m-f connectors ...
Page 31
vulcanizing tape or a cold shrink tube. If the BAT-ANT-Protector m-f is mated with connectors made of copper- alloy base material and trimetal or nickel plating, the connector area must be taped to improve long-term durability. All pertinent country, state, regional, and local safety regulations must be observed when installing and using this product.
Page 32
Figure 7: Grounding the BAT-ANT-Protector m-f You will find information on setting the transmit power in chapter “Configuring the transmit power” on page Installation DAP847 Release 01 12/2023...
2.4 Connecting the power supply WARNING ELECTRIC SHOCK ÉLECTROCUTION Before connecting the electrical wires, always verify that the requirements listed are complied with. Avant de connecter les fils électriques, vérifiez toujours que les exigences énumérées sont respectées. See “Requirements for connecting electrical wires” on page 7. See “Requirements for connecting the supply voltage”...
2.4.2 Supply voltage with PoE Your device is a PD. An 8-pin, “X”-coded M12 socket is available for PoE port. PSE (power sourcing equipment) connected via a twisted pair cable on the PoE PD port serves as the PoE power supply voltage. The PoE power supply means that no separate power supply is required for your device.
2.5 Operating the device WARNING ELECTRIC SHOCK ÉLECTROCUTION Before connecting the electrical wires, always verify that the requirements listed are complied with. Avant de connecter les fils électriques, vérifiez toujours que les exigences énumérées sont respectées. See “Requirements for connecting electrical wires” on page 7. See “Requirements for connecting the supply voltage”...
2.6 Connecting data cable Note the following general recommendations for data cable connections in environments with high electrical interference levels: Keep the length of the data cables as short as possible. Use optical data cables for the data transmission between the buildings. ...
First login (Password change) To help prevent undesired access to the device, it is imperative that you change the default password during initial setup. 3.1 First login on DAP847-XXA Perform the following steps: By default, DAP847-XXA will broadcast the WLAN ‘mywifi-xxxx’ (xxxx = the last two bytes of the access point MAC address).
Page 38
Guest Manager can check the access point status and register accounts for portal authentication. For more detailed configuration, please refer to DAP847-XXA User Manual in https://catalog.belden.com. The device prompts you to type in a new password. Type in your new password.
Page 39
Figure 14: Password change wizard Confirm your new password. Note: The page below displays to select the Country/Region and Time Zone. Figure 15: Country/Region and Time Zone selection page Installation DAP847 Release 01 12/2023...
3.2 First login on DAP847-XXC Perform the following steps: DAP847-XXC can obtain an IP address from a DHCP server. You can check the IP address on the uplink switch’s ARP table of the DHCP server, or by accessing the DAP847-XXC console using the ifconfig br-wan command.
Page 41
Viewer can check the Client status ONLY. For more detailed configuration, please refer to DAP847-XXC User Manual in https://catalog.belden.com. The device prompts you to type in a new password. Type in your new password. Choose a password that contains at least 8 characters, which includes upper-case characters, lower-case characters, numerical digits and special characters.
WPA2) is set accordingly in a device with a wireless interface and in the configuration computer For more details, please refer to DAP847-XXA User Manual in https://catalog.belden.com. 4.2 Defining WLAN basic settings on DAP847-XXC There is no WLAN setting involved on DAP847-XXC.
Configuring the transmit power 5.1 Configuring the transmit power on DAP847-XXA You can modify the transmission power and working channel for the DAP847- XXA in the RF Configuration Window. By default, the Dynamic Radio Management (DRM) technology automatically manages the working channel and transmitting power.
Page 44
Besides, you can specify the channels list or power range applicable for auto selection, which can reduce the chances of low-power transmitting or DFS (Dynamic Frequency Selection) channel conflict. Note: DFS relies on the background scanning feature. To ensure that DFS is effective, make sure that the background scanning feature is turned on.
Page 45
Parameter Specification Configures the channel width. Channel width is used to control how broad the signal is for transferring data. By increasing the channel width, you can increase the speed and throughput of a wireless broadcast. However, larger channel width brings more unstable transmission in crowded areas with a lot of frequency noise and interference.
Page 46
Parameter Specification Enable or disable IEEE 802.11ax high efficiency wireless functionality. When High Efficiency disabled, the HE (high efficiency) mode capable access point will downgrade to VHT (Very High Throughput) mode. Installation DAP847 Release 01 12/2023...
You can find information and software downloads on the Hirschmann IT product pages at: https://catalog.belden.com According to the pollution degree of the operating environment, check at regular intervals that ports in the device are not obstructed.
Disassembly Disconnect the data cable. Disable the supply voltage. Remove the antennas. Disconnect the grounding wire. Installation DAP847 Release 01 12/2023...
Technical data General technical data Dimensions See “Dimension drawings” on page 50. DAP847 W × H × D Weight DAP847 2.5 kg (5.51 lb) 4-pin, 7/8’’ connector Supply voltage Connection type Tightening torque 2.5 Nm (22 lb-in) Rated voltage DC Input: 24 V DC Rated current DC Input: 1150 mA DC Input: 16 V DC …...
8.3 WLAN module specifications 8.3.1 Radio technology Antenna connection Each WLAN module: 6 × N socket Range Depending on the antenna used, frequency range and data rate Encryption Static WEP WPA3 Personal WPA2 Personal Both (WPA2 & WPA) ...
8.3.3 Receiving sensitivity and data rate of the WLAN module The values shown in the following table are the maximum values of the WLAN module. The values are in no case to be perceived as a guaranteed property of the overall product. For some country profiles, the module reduces data rate automatically because of national standards.
8.5 Immunity Immunity Vibration IEC 60068-2-6 Test Fc test level according to IEC 61131-2 IEC 60068-2-64 test level according to IEC 61131-2 Shock IEC 60068-2-27 Test Ea level according to IEC 61131-2 Installation DAP847 Release 01 12/2023...
Scope of delivery, order number, and accessories Scope of delivery Amount Article Order number Comments 1 × DAP 847 Device 1 × General safety instructions Information sheet and Outdoor 1 × safety instructions RKC40/9, 7/8" socket: 7/8" 1 × 942 086 004 Only for device with PSU connector, 4-pin for Power supply...
Page 58
Note: Products recommended as accessories may have characteristics that do not fully correspond to those of the corresponding product. This may limit their possible usage in the overall system. Installation DAP847 Release 01 12/2023...
10 Underlying technical standards Standards Name EN 300 328 Electromagnetic compatibility and radio spectrum matters (ERM) – bandwidth transfer systems – data transmission equipment operating in 2.4 GHz ISM band and using spread spectrum modulation technology. EN 301 893 Broadband radio access networks (BRAN) – 5 GHz high performance Remote Local Area Network (RLAN) EN 302 502 Broadband Radio Access Networks (BRAN);...
Page 60
The device has an approval based on a specific standard exclusively if the approval indicator appears on the device casing. The device fulfills the technical standards named in their current versions. Installation DAP847 Release 01 12/2023...
A list of local telephone numbers and email addresses for technical support directly from Hirschmann IT is available at: https://hirschmann-it- support.belden.com. This site also includes a free knowledge base and a software download section. Installation DAP847 Release 01 12/2023...
Need help?
Do you have a question about the HIRSCHMANN IT DAP847 and is the answer not in the manual?
Questions and answers