Specifications
Requirements
Environmental
© National Instruments Corporation
This appendix lists the specifications for the VXI-1394 and
VXI-1394/G modules.
VXIbus configuration space................... 64 B
A24 or A32 space................................... Programmable
Default ............................................ None
Temperature
Operating ......................................0 to 55 °C
Storage .........................................– 20 to 70 °C
Relative humidity
Operating ........................................ 10% to 90% noncondensing
Storage ............................................ 5% to 95% noncondensing
EMI ........................................................ FCC Class A verified, EC verified
Functional shock
MIL-T-28800E Class 3 (30 g half-sine shock pulse)
Also meets IEC 60068-2-27
Random vibration
MIL-T-28800E, MIL-STD-810E Category 1
Operational .............................. 5 to 500 Hz, 0.3 g
Non-operational ....................... 5 to 500 Hz, 2.4 g
A-1
VXI-1394 Interface for Windows NT/98
A
rms
rms