Needle Stop Position - Janome HD9 Service Manual

Hide thumbs Also See for HD9:
Table of Contents

Advertisement

u
w
r
18.7 mm
e
q
t
y

9. Needle Stop Position

z
Turn the power switch q on while pressing the Up/
Down needle position button w and bobbin winding
button e at the same time.
Remove the top cover.
x
Lower the needle bar by turning the handwheel until
c
the needle point is 18.7 mm above the upper surface
of the needle plate r.
Loosen the setscrew t. Rotate the upper shaft
v
shielding plate y toward you until the green LED u
turns on.
Tighten the setscrew t and turn the power switch off.
b
Attach the top cover.
n