Jitter Performance Test Record (Options 204, 205 & 206) - HP 37718A Installation And Verification Manual

Hide thumbs Also See for 37718A:
Table of Contents

Advertisement

Table 7
Page
Test Description
No.
3-89
PDH Tx/Rx Jitter Amplitude
Accuracy
Step 8
Step 12
Step 12
Step 12
Step 12
Step 12
Step 12
Step 12
Step 12
Step 19
Step 22
Performance Tests
Jitter Performance Test Record (options 204, 205 & 206)
Jitter Performance Test Record (options 204, 205 & 206)
Hewlett-Packard Model 37718A 2.5 Gb/s Multirate Communications
Performance Analyzer (Jitter options only)
Location:
Tested by:
Temperature:
Humidity:
Performance Test Record
AIS LED On
2048 kHz - Tx
2048 kHz - Rx
8448 kHz - Tx
8448 kHz - Rx
34368 kHz - Tx
34368 kHz - Rx
139264 kHz - Tx
139264 kHz - Rx
AIS LED On
2048 kHz - Null 1.8 UI Tx 1.5 UI
2048 kHz - Null 1.8 U Rx 1.587 UI
2048 kHz - Null 4.8 UI Tx 4.4 UI
Serial No.:
Options:
Certified by:
Date:
Result
Min
Actual
Pass/Fail
0.69 UI
0.711 UI
0.69 UI
0.706 UI
0.69 UI
0.706 UI
0.68 UI
0.706 UI
Pass/Fail
Max
0.83
0.829 UI
0.83 UI
0.834 UI
0.83 UI
0.834 UI
0.84 UI
0.834 UI
Tx 2.0 UI
Rx 1.933 UI
Tx 5.1 UI
3-131

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Omniber 719Omniber 71837719a