Download Print this page

Hach AN-ISE sc Addendum To The Operator Manual page 8

Operation with the sc1500 controller

Advertisement

Available languages
  • EN

Available languages

  • ENGLISH, page 1
Operation
4.2 Sensor setup menu (Continued)
Maintenance (continued)
Name
Serial number
Sensor type
Software
Calibration history
1,2
NH
–N
4
1,3
NO
–N
3
1,2
K+
1,3
Cl
Signals
1,2
Ammonium
1,3
Nitrate
1,2
Potassium
1,3
Chloride
Reference electrode
mV RAW
Impedance status
Temperature
Moisture
RFID
Last calibration
1,2
Ammonium
1,3
Nitrate
Service
Cartridge test
Cartridge test
Maintenance
Ground rod
Reference electrode
1,3
NO
3
1,2
NH
4
ORP
1,3
Cl-
1,2
K+
Temperature
Cartridge replacement
Cleaning...
1
Applies to AN-ISE sc
2
Applies to AISE sc
3
Applies to NISE sc
8
Serial number or name of the measurement location
Serial number of the connected sensor
Instrument designation of the connected sensor
Software version
Data of the selected matrix correction and information about slope and offset of the
individual channels, for example
Matrix correction selected for ammonium
Matrix correction selected for nitrate
Matrix correction selected for potassium
Matrix correction selected for chloride
Signals and measurement results of the individual measurement channels
Display the signals and measurement results for ammonium
Shows the signals and measurement results for nitrate
Display the signals and measurement results for potassium
Display the signals and measurement results for chloride
Displays the signals and measurement results for the reference system
Display the signals and measurement results for MV RAW
Display the signals and measurement results for impedance
Display the signals and measurement results for temperature
Display the signals and measurement results for humidity
Display the signals and measurement results for RFID
Shows the age of the last matrix correction
Display the age of the last matrix correction for ammonium
Display the age of the last matrix correction for nitrate
Perform a sensor check with the test cartridge
Display whether the individual sensor channels are OK or not
Displays whether or not DIAG/TEST is OK
Displays whether or not GNDROD is OK
Displays whether or not REF channel is OK
Displays whether or not NO3 channel is OK
Displays whether or not NH4 channel is OK
Displays whether or not ORP channel is OK
Shows whether or not Cl channel is OK
Displays whether or not K channel is OK
Displays whether or not temperature channel is OK
Follow the menu process
Follow the menu process
English

Hide quick links:

Advertisement

loading

This manual is also suitable for: